Tender Details
Title
BT/GSM Project (Supply and Services)/2024,TEN23120011 Earnest Money Deposit DetailsEMD Type: PercentEMD Value: 2.0% Bhutan Telecom Ltd
Country
Language
English
Organization
Published Date
30.01.2024
Deadline Date
30.01.2024
Overview
BT/GSM Project (Supply and Services)/2024,TEN23120011 Earnest Money Deposit DetailsEMD Type: PercentEMD Value: 2.0% Evaluation DetailsFinancial Evaluation: 100% Procurement Category: GoodsDzongkhag/Location: ThimphuGoods/Services/Work Type: Supply. installation and commissioningProcurement Method: Open TenderingAnnual Procurement Plan: 2023Bidding Process: Single Stage Bidding - Single EnvelopeContact Details: manager.powerandinfra@bt.bt, dawala785@bt.bt, manager.accessnetwork@bt.bt, manager.procurement@bt.bt, procurement@bt.bt Status: Contract AwardedBidding DetailsSubmission Date: January 30 2024, 12:05 PMOpening Date: January 30 2024, 02:00 PMPrebid Date: None Prebid Place: NoneEarnest Money Deposit DetailsEMD Type: PercentEMD Value: 2.0%Evaluation DetailsFinancial Evaluation: 100%Agency DocumentsSlDocumentLink1DrawingsDownload2Integrity Pact DocumentDownload3RFPDownload4Site DetailsDownload5DrawingsDownload6DrawingsDownload7DrawingsDownload8DrawingsDownload9DrawingsDownload10DrawingsDownload11DrawingsDownload12DrawingsDownloadDocument Prerequisites For ParticipationSlDocument1Catalogue/DataSheet2Integrity Pact Document3OEM Certificate4Other Document5Tax Clearance6Trade LicenseTender Items(BOQ/BOM)SlItem CodeItem Name,Additional Description/SpecificationsUoMQty1Supply2FA01049 40M 4 Legged Tower foundation (anchor bolts, templates, etc), Set1.03FA00816 35M 3Legged Tower foundation (anchor bolts, templates, etc), Set5.04FA00817 30M 3Legged Tower foundation (anchor bolts, templates, etc), Set16.05FA00818 25M 3Legged Tower foundation (anchor bolts, templates, etc), Set24.06FA00819 20M 3Legged Tower foundation (anchor bolts, templates, etc), Set3.07FA01048 40M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 4-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamps as per the RFP., Set1.08FA00601 Tower: 35M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamp with cable and accesories as per the Specifications, Set5.09FA00296 Tower: 30M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamp with cable and accesories as per the Specification , Set16.010FA00297 Tower 25M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamps as per the Specification, Set24.011FA00298 Tower: 20M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamps as per the Specification , Set3.012FA00822 Supply of Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:3600x2600x2500(LxWxH in mm) foundation materials., Set5.013FA00300 Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:3600x2600x2500(LxWxH in mm). Panel with Foam-60mm, Material of skin- 0.6mmx0.6mm pre- Floor- Ply 18mm and PVC 2mm , Set5.014FA00823 Supply of Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:6000x3600x2600(LxWxH in mm) foundation materials, Set1.015FA00824 Supply of Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:6000x3600x2600(LxWxH in mm). Panel with Foam-60mm, Material of skin- 0.6mmx0.6mm pre- Floor- Ply 18mm and PVC 2mm (as per drawing attached in RFP), Set1.016FA00821 15M Monopole foundation (anchor bolts, templates, etc), Set47.017FA00303 Monopole: 15M With separate Earthing provisions. Tower should have name plate (company name (Bhutan Telecom Limited, Height and year of installation), 3 LED Lamp with LDR Sensor, 3 nos of antenna mounting structure (1.5m), 4 nos of radio mounting structure (500-600mm) with Meter Boix, Fall Arrestor with Wire rope of 8mm & Rope Grab (Both Material should be Stainless Steel 316) arrangement as shown in the drawing., Set29.018FA00304 Monopole: 15M With separate Earthing provisions. Tower should have name plate (company name (Bhutan Telecom Limited, Height and year of installation), 2 LED Lamp with LDR Sensor, 3 nos of antenna mounting structure (1.5m), 4 nos of radio mounting structure (500-600mm). with Meter Boix, Fall Arrestor with Wire rope of 8mm & Rope Grab (Both Material should be Stainless Steel 316) arrangement as shown in the drawing., Set13.019FA01050 15M With separate Earthing provisions (as per design attached in RFP) Tower should have name plate [company name (Bhutan Telecom Limited, Height and year of installation), without LED Lamp with LDR Sensor and lighting cables and accessories], Set2.020FA00826 15M Flange Joint With separate Earthing provisions (as per design attached in RFP) Tower should have name plate [company name (Bhutan Telecom Limited, Height and year of installation), 3 LED Lamp with LDR Sensor and lighting cables and accessories], Set3.021FA01072 VRLA- 2V/450 AH @ C10 @ 1.75 ECV @ 27 Deg.C (+)48V DC, 450 AH * 2 Banks = 900 AH per site with battery racks, stands, connectors, battery remover, transparent covers,etc (Make: HBL/ Amaraja/Rocket), Banks3.022FA01073 Rectifiers (500 amps, 24 kW) floor mounted with stand (1 mtr height above floor) IP Vac = 180 – 280 Vac; OP = (-48V DC), 500 Amps, Modular Type including 8/6 no of modules having 60/80 Amps per module. Must have load facility to connect both critical and non-critical loads below mentioned ratings of DC MCBs and HRC Fuse. i.                SP MCBs: 63 amps – 2 Nos, 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 5 Nos ii.              HRC Fuse: 100 amps – 2 Nos Also, should have an inbuilt controller and safety devices such as BLVD and LLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set3.023FA00275 DCPDB (Rating: 100 amps, -48VDC. This Pre-Wired Power Distribution Board shall provide all the load conections with proper rating of MCBs and additional battery charging facilities. DC MCB DP (63A-2 nos,32 A-6nos.16A-10nos)) (Make: Any Quality Brand as per given drawing specification MCB brand), nos3.024FA00276 ACPDB (Rating: 100 amps, 230 V AC Pre-wired/assembled with inbuilt MCBs (2P, 32 amps - 4 Nos, 2 P, 16 amps- 8 Nos, 2P, 10 amps- 6 nos ), nos3.025FA01074 DC Power Cable 70 Sq.mm ( RED) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.026FA01075 DC Power Cable 70 Sq.mm (BLACK) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.027FA01076 DC Power Cable 25 Sq.mm ( RED) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (25 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.028FA01077 DC Power Cable 25 Sq.mm (BLACK) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (25 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.029FA01078 DC Power Cable 4 Sq.mm (BLACK) 1.1KV, 3C PVC Insulated, unarmoured multi-strand copper Cable (25 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.030FA01079 DC Power Cable 4 Sq.mm (Green) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (100 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.031FA01080 Chemical Based Earthing System with -48VDC DC SPD:CHEMICAL EARTHING . CPRI /ISO Approved Chemical earthing . Tri-rod (5 ft long 12mm Dia. \ 2 set), GAF (Chemical) \ 2X40 kg, Copper revit \ 10 nos, Earth Distribution bus bar \ 2 Nos, earth pit cover, copper strip 25X3 mm. \ 30 mtr per set, salt \ 2 X 10 kg per set, Charcoal \ 2 x 5 kg per set, connectors, lugs,clamps, etc Surge Protection Device, Un (dc) = 48V, Uc (dc) = 75V, In (8/20μs)= 40kA with appropriate MCB and BOX prewired with fault indicator available (Make: ICON/PRAGATI/ERICO/LPI), Set3.032FA00605 Free cooling unit: Air outlet configuration Gravity based dampers without any fan. Worm-protection net. The assembly shall ensure no water / rain leak into the shelter. The damper is closed when AC is operating and damper will open when FCU is operating Air inlet configuration Rain-proof cover, 48 V DC powered Axial flow fan, air filtering net, Gravity based dampers, worm-protection net, fine filters Filtration 90% down to 20 microns Airflow at full capacity 1200 + 200 CFM at 48 V (May be suitably designed as per site requirement). 2/4 fans may be used to meet the total CFM requirement, if required. Microprocessor based controller The Control unit (controller) shall be provided to automatically control the operation of FCU in all possible conditions in telecommunications equipment room in auto mode. It shall also have facility to switch on and off the air conditioning units installed in the room. Auto Mode Operation – 1. Under favorable environment conditions, the controller shall switch off the air-conditioning unit and start free cooling. 2. Whenever room temperature rises above set temperature, then controller shall switch off the FCU / associated dampers and switch on the air-conditioning unit. 3. The controller shall switch off the FCU / associated dampers if battery voltage drop below set voltage. 4. Controller shall measure Run Hour of FCU Mode and Cooling Mode. 5. When ever the temperature of BTS exceeds 40 Deg C on a/c of AC failure or any other reason, there should be a provision to start Free Cooling Unit again through controller for emergency cooling. (Make: Pragati/ICON/Delta/Vertiv or of equivalent), Set3.033FA00606 Split Type Airconditioners ( Stabiliser free, inverter air conditioner: 1.5T, Single Phase,50Hz,Input Volt=150 - 230V, Split type with appropriate rating of MCBs,High Low Pressure Pipe=4 m each, outlet drain pipe =10 m each flexible, cable size=4 sqmm cu stranded 3 core=5 m, MCBs=SPN, 16Amps, with stand to fix the outdoor unit. Refrigerant: R32 (Make: Samsung/Hitachi/Toshiba/Blue star/ LG/Voltas/Godrej/Daikin or of Equivalent brand), Set3.034FA00475 Earth Cable ( Green or Green/yellow mixed), PVC insulated single multi strand core copper conductor ( 1.1KV) 1C , 25 sq.mm (50M per site) , nos3.035FA00901 LPS (Lightning protection system): 1. Lightning Arrester: Supply of Lightning Protection System that works on Early Streamer Emission Technology having coverage radius >80 mtrs when mounted at a height of 50 mtrs giving level I protection. Tested ininternational high tension laboratory, tested/approved by CPRI, India 2. FRP Mast- 2 mtrs. 3.Lightning Strike Counter with IP-65 Enclosure 4. HVSC Down copper conductor (50 sq.mm copper) 5. Chemical Earthing: 1. Tri-rod 99.9% copper (5 ft long 12 mm Dia \ 2 set) welded together and with connection strip & fitted with 4 sets for connecting 2. GEM (Chemical) \ 2X40 kg 3. Copper revit \ 10 nos 4. Earth Distribution bus bar \ 2 Nos, 5. Earth pit cover - 2 nos. 5. Copper 99.9% copper) strip 25X3 mm- 30 mtr 6.Salt- 2 X 10 kg per set, 7. Charcoal \ 2 x 5 kg per set. 8. Connectors, lugs,clamps, etc (Make: LPI/Erico/Bakiral or of equivalent) , Set3.036FA00288 TVSS/SPD: Surge Protection Device, Single Phase (230V AC), Max discharge current 100kA (10/350 µs), Fault Indicator Available, Protection Mode: L-N/N-PE, with appropriate MCB and Box, prewired (Make: LPI/Emerson/Erico/Eaton/Phoenix), Set3.037FA01064 Copper Terminal Ends (Ring Type)/Lugs: 4 sq.mm (20 nos Ring Type ), Lot3.038FA01065 Copper Terminal Ends (Pin Type)/Lugs: 4 sq.mm (10 nos Ring Type ), Lot3.039FA01066 Copper Terminal Ends (Ring Type)/Lugs: 25 sq.mm ( 15 nos Ring Type ), Lot3.040FA01067 Copper Terminal Ends (Pin Type)/Lugs: 25 sq.mm ( 5 nos Pin Type ), Lot3.041FA01068 Copper Terminal Ends (Ring Type)/Lugs: 70 sq.mm (15 nos Ring), Lot3.042FA01069 PVC Insulation Tape: Red (2 rolls per site), Lot3.043FA01070 PVC Insulation Tape: Black (2 rolls per site), Lot3.044FA01071 PVC Insulation Tape: Green (2 rolls per site), Lot3.045FA00291 Cable Tie , Natural 6", Inner Unit Pack: 100 pieces per box , Box3.046FA00292 Cable Tie, Natural 8", Inner Unit Pack: 100 pieces per box , Box3.047FA00293 Cable Tie, Natural 12", inner Unit Pack: 100 pieces per box, Box3.048FA00294 Cable Tie, Heavy Duty Weather Resistant 8", Inner Unit Pack: 100 per box , Box3.049FA00295 Cable Tie , Heavy Duty Weather Resistant 12", Inner Unit Pack: 100 pieces per box, Box3.050FA01072 VRLA- 2V/450 AH @ C10 @ 1.75 ECV @ 27 Deg.C (+)48V DC, 450 AH * 2 Banks = 900 AH per site with battery racks, stands, connectors, battery remover, transparent covers,etc (Make: HBL/ Amaraja/Rocket), Banks1.051FA00275 DCPDB ( Rating: 100amps, -48VDCPDC. This Pre-wired Power Distribution Board shall provide all the connections to battery bank with proper rating of DC MCBs and additional battery charging facilities. MCB dual pole rating as 63A 2 nos, 32A 4nos, 16A 10nos, nos37.052FA00276 ACPDB (Rating: 100 amps, 230 V AC Pre-wired/assembled with inbuilt MCBs (2P, 32 amps - 4 Nos, 2 P, 16 amps- 8 Nos, 2P, 10 amps- 6 nos ), nos28.053FA01074 DC Power Cable 70 Sq.mm ( RED) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos7.054FA01075 DC Power Cable 70 Sq.mm (BLACK) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos7.055FA01073 Rectifiers (500 amps, 24 kW) floor mounted with stand (1 mtr height above floor) IP Vac = 180 – 280 Vac; OP = (-48V DC), 500 Amps, Modular Type including 8/6 no of modules having 60/80 Amps per module. Must have load facility to connect both critical and non-critical loads below mentioned ratings of DC MCBs and HRC Fuse. i.                SP MCBs: 63 amps – 2 Nos, 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 5 Nos ii.              HRC Fuse: 100 amps – 2 Nos Also, should have an inbuilt controller and safety devices such as BLVD and LLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set4.056FA01081 Rectifiers (300 amps, 14.4 kW) 19” rack mount with accessories IP Vac = 180 – 280 Vac; OP = (-48V DC), 300 Amps, Modular Type including 5/4 no of modules having 60/80 Amps per module. Must have load facility to connect loads as below mentioned ratings of DC MCBs i.                SP MCBs: 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 4 Nos Battery MCB Rating: 120 amps dc – 2 Nos Also, should have an inbuilt controller and safety devices such as BLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set6.057FA01082 Hybrid Rectifiers (500 amps, 24 kW) floor mounted with stand (1 mtr height above floor) IP Vac = 180 – 280 Vac; OP = (-48V DC), 500 Amps, Modular Type including 4/3 no of modules having 60/80 Amps per module. Solar: MPPT Modules: (4/3 no of modules having 60/80 amps per MPPT), Input - 60 to 400 Vdc, Output - 42 to 58V dc. Must have load facility to connect both critical and non-critical loads below mentioned ratings of DC MCBs and HRC Fuse. i.                SP MCBs: 63 amps – 2 Nos, 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 5 Nos, ii.              HRC Fuse: 100 amps – 2 Nos. Also, should have an inbuilt controller and safety devices such as BLVD and LLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set5.058FA00606 Split Type Airconditioners ( Stabiliser free, inverter air conditioner: 1.5T, Single Phase,50Hz,Input Volt=150 - 230V, Split type with appropriate rating of MCBs,High Low Pressure Pipe=4 m each, outlet drain pipe =10 m each flexible, cable size=4 sqmm cu stranded 3 core=5 m, MCBs=SPN, 16Amps, with stand to fix the outdoor unit. Refrigerant: R32 (Make: Samsung/Hitachi/Toshiba/Blue star/ LG/Voltas/Godrej/Daikin) , Set1.059FA01080 Chemical Based Earthing System with -48VDC DC SPD:CHEMICAL EARTHING . CPRI /ISO Approved Chemical earthing . Tri-rod (5 ft long 12mm Dia. \ 2 set), GAF (Chemical) \ 2X40 kg, Copper revit \ 10 nos, Earth Distribution bus bar \ 2 Nos, earth pit cover, copper strip 25X3 mm. \ 30 mtr per set, salt \ 2 X 10 kg per set, Charcoal \ 2 x 5 kg per set, connectors, lugs,clamps, etc Surge Protection Device, Un (dc) = 48V, Uc (dc) = 75V, In (8/20μs)= 40kA with appropriate MCB and BOX prewired with fault indicator available (Make: ICON/PRAGATI/ERICO/LPI), Set11.060FA00901 LPS (Lightning protection system): 1. Lightning Arrester: Supply of Lightning Protection System that works on Early Streamer Emission Technology having coverage radius >80 mtrs when mounted at a height of 50 mtrs giving level I protection. Tested ininternational high tension laboratory, tested/approved by CPRI, India 2. FRP Mast- 2 mtrs. 3.Lightning Strike Counter with IP-65 Enclosure 4. HVSC Down copper conductor (50 sq.mm copper) 5. Chemical Earthing: 1. Tri-rod 99.9% copper (5 ft long 12 mm Dia \ 2 set) welded together and with connection strip & fitted with 4 sets for connecting 2. GEM (Chemical) \ 2X40 kg 3. Copper revit \ 10 nos 4. Earth Distribution bus bar \ 2 Nos, 5. Earth pit cover - 2 nos. 5. Copper 99.9% copper) strip 25X3 mm- 30 mtr 6.Salt- 2 X 10 kg per set, 7. Charcoal \ 2 x 5 kg per set. 8. Connectors, lugs,clamps, etc (Make: LPI/Erico/Bakiral or of equivalent) , Set11.061FA01083 LV Aerial Bundled Conductor with messenger wire: 1.1kV,2C PVC insulated, unarmored multi-strand aluminum cable 50 sqmm, mtrs12120.062FA00400 Roxtec (GH 6x1/18 AISI316), Set6.063FA00301 Antenna Mounting Structure (Tower leg/angular tower), Set90.064Services65SW00588 Transporation of Tower and foundation materials to designated site, nos49.066SW00639 40M 3Legged Tower Erection including earthing, nos1.067SW00590 35M 3Legged Tower Erection including earthing, nos5.068SW00591 30M 3Legged Tower Erection including earthing, nos16.069SW00592 25M 3Legged Tower Erection including earthing, nos24.070SW00593 20M 3Legged Tower Erection including earthing, nos3.071SW00595 Transporation of shelter and foundation materials to designated site, nos6.072SW00596 Shelter Erection including earthing, nos5.073SW00597 Shelter Erection :6000x3600x2600 including earthing, nos1.074SW00598 Transporation of AC Power to designated site, nos3.075SW00600 Installation of AC Power including earthing, etc as per details provided, nos3.076SW00605 Transporation of Monopole and foundation materials to designated site, nos47.077SW00606 Monopole Erection including earthing and lighting, nos47.0Amendment DetailsSlIDDateDetailsRemarks1TAM24010004January 30 2024, 11:59 AMSubmission Date changed from 2024-01-30 11:00:00 to 2024-01-30 12:05:00one vendor has submitted EMD 10:33 we have missed to approve BT/GSM Project (Supply and Services)/2024 BT/GSM Project (Supply and Services)/2024 Bhutan Telecom Ltd Contract AwardedProcurement Category: GoodsDzongkhag/Location: ThimphuGoods/Services/Work Type: Supply. installation and commissioningProcurement Method: Open TenderingAnnual Procurement Plan: 2023Bidding Process: Single Stage Bidding - Single EnvelopeContact Details: manager.powerandinfra@bt.bt, dawala785@bt.bt, manager.accessnetwork@bt.bt, manager.procurement@bt.bt, procurement@bt.bt Status: Contract AwardedBidding DetailsSubmission Date: January 30 2024, 12:05 PMOpening Date: January 30 2024, 02:00 PMPrebid Date: None Prebid Place: NoneEarnest Money Deposit DetailsEMD Type: PercentEMD Value: 2.0%Evaluation DetailsFinancial Evaluation: 100%Agency DocumentsSlDocumentLink1DrawingsDownload2Integrity Pact DocumentDownload3RFPDownload4Site DetailsDownload5DrawingsDownload6DrawingsDownload7DrawingsDownload8DrawingsDownload9DrawingsDownload10DrawingsDownload11DrawingsDownload12DrawingsDownloadDocument Prerequisites For ParticipationSlDocument1Catalogue/DataSheet2Integrity Pact Document3OEM Certificate4Other Document5Tax Clearance6Trade LicenseTender Items(BOQ/BOM)SlItem CodeItem Name,Additional Description/SpecificationsUoMQty1Supply2FA01049 40M 4 Legged Tower foundation (anchor bolts, templates, etc), Set1.03FA00816 35M 3Legged Tower foundation (anchor bolts, templates, etc), Set5.04FA00817 30M 3Legged Tower foundation (anchor bolts, templates, etc), Set16.05FA00818 25M 3Legged Tower foundation (anchor bolts, templates, etc), Set24.06FA00819 20M 3Legged Tower foundation (anchor bolts, templates, etc), Set3.07FA01048 40M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 4-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamps as per the RFP., Set1.08FA00601 Tower: 35M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamp with cable and accesories as per the Specifications, Set5.09FA00296 Tower: 30M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamp with cable and accesories as per the Specification , Set16.010FA00297 Tower 25M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamps as per the Specification, Set24.011FA00298 Tower: 20M self-supporting Complete supply, fabrication, galvanization (min 85micron) self-supporting 3-legged angular construction with separate Earthing provisions. Tower should have name plate (supplier company name, Height and year of installation).Antenna mounting structures (3m) and aviation lamps as per the Specification , Set3.012FA00822 Supply of Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:3600x2600x2500(LxWxH in mm) foundation materials., Set5.013FA00300 Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:3600x2600x2500(LxWxH in mm). Panel with Foam-60mm, Material of skin- 0.6mmx0.6mm pre- Floor- Ply 18mm and PVC 2mm , Set5.014FA00823 Supply of Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:6000x3600x2600(LxWxH in mm) foundation materials, Set1.015FA00824 Supply of Pre-fabricated shelter with external sheet roofing and lighting facility: Ext:6000x3600x2600(LxWxH in mm). Panel with Foam-60mm, Material of skin- 0.6mmx0.6mm pre- Floor- Ply 18mm and PVC 2mm (as per drawing attached in RFP), Set1.016FA00821 15M Monopole foundation (anchor bolts, templates, etc), Set47.017FA00303 Monopole: 15M With separate Earthing provisions. Tower should have name plate (company name (Bhutan Telecom Limited, Height and year of installation), 3 LED Lamp with LDR Sensor, 3 nos of antenna mounting structure (1.5m), 4 nos of radio mounting structure (500-600mm) with Meter Boix, Fall Arrestor with Wire rope of 8mm & Rope Grab (Both Material should be Stainless Steel 316) arrangement as shown in the drawing., Set29.018FA00304 Monopole: 15M With separate Earthing provisions. Tower should have name plate (company name (Bhutan Telecom Limited, Height and year of installation), 2 LED Lamp with LDR Sensor, 3 nos of antenna mounting structure (1.5m), 4 nos of radio mounting structure (500-600mm). with Meter Boix, Fall Arrestor with Wire rope of 8mm & Rope Grab (Both Material should be Stainless Steel 316) arrangement as shown in the drawing., Set13.019FA01050 15M With separate Earthing provisions (as per design attached in RFP) Tower should have name plate [company name (Bhutan Telecom Limited, Height and year of installation), without LED Lamp with LDR Sensor and lighting cables and accessories], Set2.020FA00826 15M Flange Joint With separate Earthing provisions (as per design attached in RFP) Tower should have name plate [company name (Bhutan Telecom Limited, Height and year of installation), 3 LED Lamp with LDR Sensor and lighting cables and accessories], Set3.021FA01072 VRLA- 2V/450 AH @ C10 @ 1.75 ECV @ 27 Deg.C (+)48V DC, 450 AH * 2 Banks = 900 AH per site with battery racks, stands, connectors, battery remover, transparent covers,etc (Make: HBL/ Amaraja/Rocket), Banks3.022FA01073 Rectifiers (500 amps, 24 kW) floor mounted with stand (1 mtr height above floor) IP Vac = 180 – 280 Vac; OP = (-48V DC), 500 Amps, Modular Type including 8/6 no of modules having 60/80 Amps per module. Must have load facility to connect both critical and non-critical loads below mentioned ratings of DC MCBs and HRC Fuse. i.                SP MCBs: 63 amps – 2 Nos, 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 5 Nos ii.              HRC Fuse: 100 amps – 2 Nos Also, should have an inbuilt controller and safety devices such as BLVD and LLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set3.023FA00275 DCPDB (Rating: 100 amps, -48VDC. This Pre-Wired Power Distribution Board shall provide all the load conections with proper rating of MCBs and additional battery charging facilities. DC MCB DP (63A-2 nos,32 A-6nos.16A-10nos)) (Make: Any Quality Brand as per given drawing specification MCB brand), nos3.024FA00276 ACPDB (Rating: 100 amps, 230 V AC Pre-wired/assembled with inbuilt MCBs (2P, 32 amps - 4 Nos, 2 P, 16 amps- 8 Nos, 2P, 10 amps- 6 nos ), nos3.025FA01074 DC Power Cable 70 Sq.mm ( RED) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.026FA01075 DC Power Cable 70 Sq.mm (BLACK) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.027FA01076 DC Power Cable 25 Sq.mm ( RED) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (25 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.028FA01077 DC Power Cable 25 Sq.mm (BLACK) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (25 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.029FA01078 DC Power Cable 4 Sq.mm (BLACK) 1.1KV, 3C PVC Insulated, unarmoured multi-strand copper Cable (25 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.030FA01079 DC Power Cable 4 Sq.mm (Green) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (100 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos3.031FA01080 Chemical Based Earthing System with -48VDC DC SPD:CHEMICAL EARTHING . CPRI /ISO Approved Chemical earthing . Tri-rod (5 ft long 12mm Dia. \ 2 set), GAF (Chemical) \ 2X40 kg, Copper revit \ 10 nos, Earth Distribution bus bar \ 2 Nos, earth pit cover, copper strip 25X3 mm. \ 30 mtr per set, salt \ 2 X 10 kg per set, Charcoal \ 2 x 5 kg per set, connectors, lugs,clamps, etc Surge Protection Device, Un (dc) = 48V, Uc (dc) = 75V, In (8/20μs)= 40kA with appropriate MCB and BOX prewired with fault indicator available (Make: ICON/PRAGATI/ERICO/LPI), Set3.032FA00605 Free cooling unit: Air outlet configuration Gravity based dampers without any fan. Worm-protection net. The assembly shall ensure no water / rain leak into the shelter. The damper is closed when AC is operating and damper will open when FCU is operating Air inlet configuration Rain-proof cover, 48 V DC powered Axial flow fan, air filtering net, Gravity based dampers, worm-protection net, fine filters Filtration 90% down to 20 microns Airflow at full capacity 1200 + 200 CFM at 48 V (May be suitably designed as per site requirement). 2/4 fans may be used to meet the total CFM requirement, if required. Microprocessor based controller The Control unit (controller) shall be provided to automatically control the operation of FCU in all possible conditions in telecommunications equipment room in auto mode. It shall also have facility to switch on and off the air conditioning units installed in the room. Auto Mode Operation – 1. Under favorable environment conditions, the controller shall switch off the air-conditioning unit and start free cooling. 2. Whenever room temperature rises above set temperature, then controller shall switch off the FCU / associated dampers and switch on the air-conditioning unit. 3. The controller shall switch off the FCU / associated dampers if battery voltage drop below set voltage. 4. Controller shall measure Run Hour of FCU Mode and Cooling Mode. 5. When ever the temperature of BTS exceeds 40 Deg C on a/c of AC failure or any other reason, there should be a provision to start Free Cooling Unit again through controller for emergency cooling. (Make: Pragati/ICON/Delta/Vertiv or of equivalent), Set3.033FA00606 Split Type Airconditioners ( Stabiliser free, inverter air conditioner: 1.5T, Single Phase,50Hz,Input Volt=150 - 230V, Split type with appropriate rating of MCBs,High Low Pressure Pipe=4 m each, outlet drain pipe =10 m each flexible, cable size=4 sqmm cu stranded 3 core=5 m, MCBs=SPN, 16Amps, with stand to fix the outdoor unit. Refrigerant: R32 (Make: Samsung/Hitachi/Toshiba/Blue star/ LG/Voltas/Godrej/Daikin or of Equivalent brand), Set3.034FA00475 Earth Cable ( Green or Green/yellow mixed), PVC insulated single multi strand core copper conductor ( 1.1KV) 1C , 25 sq.mm (50M per site) , nos3.035FA00901 LPS (Lightning protection system): 1. Lightning Arrester: Supply of Lightning Protection System that works on Early Streamer Emission Technology having coverage radius >80 mtrs when mounted at a height of 50 mtrs giving level I protection. Tested ininternational high tension laboratory, tested/approved by CPRI, India 2. FRP Mast- 2 mtrs. 3.Lightning Strike Counter with IP-65 Enclosure 4. HVSC Down copper conductor (50 sq.mm copper) 5. Chemical Earthing: 1. Tri-rod 99.9% copper (5 ft long 12 mm Dia \ 2 set) welded together and with connection strip & fitted with 4 sets for connecting 2. GEM (Chemical) \ 2X40 kg 3. Copper revit \ 10 nos 4. Earth Distribution bus bar \ 2 Nos, 5. Earth pit cover - 2 nos. 5. Copper 99.9% copper) strip 25X3 mm- 30 mtr 6.Salt- 2 X 10 kg per set, 7. Charcoal \ 2 x 5 kg per set. 8. Connectors, lugs,clamps, etc (Make: LPI/Erico/Bakiral or of equivalent) , Set3.036FA00288 TVSS/SPD: Surge Protection Device, Single Phase (230V AC), Max discharge current 100kA (10/350 µs), Fault Indicator Available, Protection Mode: L-N/N-PE, with appropriate MCB and Box, prewired (Make: LPI/Emerson/Erico/Eaton/Phoenix), Set3.037FA01064 Copper Terminal Ends (Ring Type)/Lugs: 4 sq.mm (20 nos Ring Type ), Lot3.038FA01065 Copper Terminal Ends (Pin Type)/Lugs: 4 sq.mm (10 nos Ring Type ), Lot3.039FA01066 Copper Terminal Ends (Ring Type)/Lugs: 25 sq.mm ( 15 nos Ring Type ), Lot3.040FA01067 Copper Terminal Ends (Pin Type)/Lugs: 25 sq.mm ( 5 nos Pin Type ), Lot3.041FA01068 Copper Terminal Ends (Ring Type)/Lugs: 70 sq.mm (15 nos Ring), Lot3.042FA01069 PVC Insulation Tape: Red (2 rolls per site), Lot3.043FA01070 PVC Insulation Tape: Black (2 rolls per site), Lot3.044FA01071 PVC Insulation Tape: Green (2 rolls per site), Lot3.045FA00291 Cable Tie , Natural 6", Inner Unit Pack: 100 pieces per box , Box3.046FA00292 Cable Tie, Natural 8", Inner Unit Pack: 100 pieces per box , Box3.047FA00293 Cable Tie, Natural 12", inner Unit Pack: 100 pieces per box, Box3.048FA00294 Cable Tie, Heavy Duty Weather Resistant 8", Inner Unit Pack: 100 per box , Box3.049FA00295 Cable Tie , Heavy Duty Weather Resistant 12", Inner Unit Pack: 100 pieces per box, Box3.050FA01072 VRLA- 2V/450 AH @ C10 @ 1.75 ECV @ 27 Deg.C (+)48V DC, 450 AH * 2 Banks = 900 AH per site with battery racks, stands, connectors, battery remover, transparent covers,etc (Make: HBL/ Amaraja/Rocket), Banks1.051FA00275 DCPDB ( Rating: 100amps, -48VDCPDC. This Pre-wired Power Distribution Board shall provide all the connections to battery bank with proper rating of DC MCBs and additional battery charging facilities. MCB dual pole rating as 63A 2 nos, 32A 4nos, 16A 10nos, nos37.052FA00276 ACPDB (Rating: 100 amps, 230 V AC Pre-wired/assembled with inbuilt MCBs (2P, 32 amps - 4 Nos, 2 P, 16 amps- 8 Nos, 2P, 10 amps- 6 nos ), nos28.053FA01074 DC Power Cable 70 Sq.mm ( RED) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos7.054FA01075 DC Power Cable 70 Sq.mm (BLACK) 1.1KV, 1C PVC Insulated, unarmoured multi-strand copper Cable (40 mtr/site) (Make: Polycab/ RR/Havell's or of Equivalent brand), nos7.055FA01073 Rectifiers (500 amps, 24 kW) floor mounted with stand (1 mtr height above floor) IP Vac = 180 – 280 Vac; OP = (-48V DC), 500 Amps, Modular Type including 8/6 no of modules having 60/80 Amps per module. Must have load facility to connect both critical and non-critical loads below mentioned ratings of DC MCBs and HRC Fuse. i.                SP MCBs: 63 amps – 2 Nos, 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 5 Nos ii.              HRC Fuse: 100 amps – 2 Nos Also, should have an inbuilt controller and safety devices such as BLVD and LLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set4.056FA01081 Rectifiers (300 amps, 14.4 kW) 19” rack mount with accessories IP Vac = 180 – 280 Vac; OP = (-48V DC), 300 Amps, Modular Type including 5/4 no of modules having 60/80 Amps per module. Must have load facility to connect loads as below mentioned ratings of DC MCBs i.                SP MCBs: 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 4 Nos Battery MCB Rating: 120 amps dc – 2 Nos Also, should have an inbuilt controller and safety devices such as BLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set6.057FA01082 Hybrid Rectifiers (500 amps, 24 kW) floor mounted with stand (1 mtr height above floor) IP Vac = 180 – 280 Vac; OP = (-48V DC), 500 Amps, Modular Type including 4/3 no of modules having 60/80 Amps per module. Solar: MPPT Modules: (4/3 no of modules having 60/80 amps per MPPT), Input - 60 to 400 Vdc, Output - 42 to 58V dc. Must have load facility to connect both critical and non-critical loads below mentioned ratings of DC MCBs and HRC Fuse. i.                SP MCBs: 63 amps – 2 Nos, 32 amps – 4 Nos, 20 amps – 5 Nos, 16 amps – 5 Nos, ii.              HRC Fuse: 100 amps – 2 Nos. Also, should have an inbuilt controller and safety devices such as BLVD and LLVD having the following features to monitor the status of the rectifier, battery, room temperature, ac mains available or not, DG supply available or not, rectifier failure alarm, load on battery, load on AC or DG. All these parameters are to be monitored remotely using LAN/Modem, GSM, GPRS, Web browser. Remote alarming using dry contacts/SNMP. Should include class C AC SPD and DC SPD and must be compatible with Li Batteries without having to upgrade the software. (Make: Vertiv/Delta/Exicom/Huawei/Equivalent), Set5.058FA00606 Split Type Airconditioners ( Stabiliser free, inverter air conditioner: 1.5T, Single Phase,50Hz,Input Volt=150 - 230V, Split type with appropriate rating of MCBs,High Low Pressure Pipe=4 m each, outlet drain pipe =10 m each flexible, cable size=4 sqmm cu stranded 3 core=5 m, MCBs=SPN, 16Amps, with stand to fix the outdoor unit. Refrigerant: R32 (Make: Samsung/Hitachi/Toshiba/Blue star/ LG/Voltas/Godrej/Daikin) , Set1.059FA01080 Chemical Based Earthing System with -48VDC DC SPD:CHEMICAL EARTHING . CPRI /ISO Approved Chemical earthing . Tri-rod (5 ft long 12mm Dia. \ 2 set), GAF (Chemical) \ 2X40 kg, Copper revit \ 10 nos, Earth Distribution bus bar \ 2 Nos, earth pit cover, copper strip 25X3 mm. \ 30 mtr per set, salt \ 2 X 10 kg per set, Charcoal \ 2 x 5 kg per set, connectors, lugs,clamps, etc Surge Protection Device, Un (dc) = 48V, Uc (dc) = 75V, In (8/20μs)= 40kA with appropriate MCB and BOX prewired with fault indicator available (Make: ICON/PRAGATI/ERICO/LPI), Set11.060FA00901 LPS (Lightning protection system): 1. Lightning Arrester: Supply of Lightning Protection System that works on Early Streamer Emission Technology having coverage radius >80 mtrs when mounted at a height of 50 mtrs giving level I protection. Tested ininternational high tension laboratory, tested/approved by CPRI, India 2. FRP Mast- 2 mtrs. 3.Lightning Strike Counter with IP-65 Enclosure 4. HVSC Down copper conductor (50 sq.mm copper) 5. Chemical Earthing: 1. Tri-rod 99.9% copper (5 ft long 12 mm Dia \ 2 set) welded together and with connection strip & fitted with 4 sets for connecting 2. GEM (Chemical) \ 2X40 kg 3. Copper revit \ 10 nos 4. Earth Distribution bus bar \ 2 Nos, 5. Earth pit cover - 2 nos. 5. Copper 99.9% copper) strip 25X3 mm- 30 mtr 6.Salt- 2 X 10 kg per set, 7. Charcoal \ 2 x 5 kg per set. 8. Connectors, lugs,clamps, etc (Make: LPI/Erico/Bakiral or of equivalent) , Set11.061FA01083 LV Aerial Bundled Conductor with messenger wire: 1.1kV,2C PVC insulated, unarmored multi-strand aluminum cable 50 sqmm, mtrs12120.062FA00400 Roxtec (GH 6x1/18 AISI316), Set6.063FA00301 Antenna Mounting Structure (Tower leg/angular tower), Set90.064Services65SW00588 Transporation of Tower and foundation materials to designated site, nos49.066SW00639 40M 3Legged Tower Erection including earthing, nos1.067SW00590 35M 3Legged Tower Erection including earthing, nos5.068SW00591 30M 3Legged Tower Erection including earthing, nos16.069SW00592 25M 3Legged Tower Erection including earthing, nos24.070SW00593 20M 3Legged Tower Erection including earthing, nos3.071SW00595 Transporation of shelter and foundation materials to designated site, nos6.072SW00596 Shelter Erection including earthing, nos5.073SW00597 Shelter Erection :6000x3600x2600 including earthing, nos1.074SW00598 Transporation of AC Power to designated site, nos3.075SW00600 Installation of AC Power including earthing, etc as per details provided, nos3.076SW00605 Transporation of Monopole and foundation materials to designated site, nos47.077SW00606 Monopole Erection including earthing and lighting, nos47.0Amendment DetailsSlIDDateDetailsRemarks1TAM24010004January 30 2024, 11:59 AMSubmission Date changed from 2024-01-30 11:00:00 to 2024-01-30 12:05:00one vendor has submitted EMD 10:33 we have missed to approve Bhutan Telecom Ltd Goods Contract Awarded
NAICS
Power Nonferrous Metal (except Copper and Aluminum) Rolling Asphalt Paving Navigational Bolt Piece Goods Electric Power Transmission Nonferrous Metal (except Copper and Aluminum) Rolling Other Foundation Copper Other Foundation Roofing Ventilation All Other Telecommunications Apparel All Other Telecommunications Aluminum Sheet Copper Rolling Automotive Parts All Other Telecommunications Construction Scenic and Sightseeing Transportation Copper Rolling Machinery Other Aluminum Rolling Roofing Rope Measuring Agriculture Navigational Foundation Photographic Film Environment Dry Electroplating Agencies Ventilation Copper Water Piece Goods Construction Process Metal Can
CPVS
Dried, salted, smoked or seasoned meat Telecommunications equipment Plates Parts of structures Inverters Earthmoving and excavating machinery, and associated parts Iron, lead, zinc, tin and copper Foundation work Drain pipes Laboratory, optical and precision equipments (excl. glasses) Shelters Batteries System, storage and content management software package Ties Switches Terminals Mains Wire Bolts Control, safety, signalling and light equipment Construction, foundation and surface works for highways, roads Lavatory seats, covers, bowls and cisterns Cable Boards Control, safety or signalling equipment for inland waterways Wheels, parts and accessories Parts of fans Cordage, rope, twine and netting Racking Fabrication work Salt Rolls Wells construction work Towers, lattice masts, derricks and pylons PH meters Lead Rectifiers Fans Fuses Meters Flanges Safety cases Sensors Document creation, drawing, imaging, scheduling and productivity software package Control, safety or signalling equipment for parking facilities Construction work Templates Command, control, communication systems Copper Structures and parts Insulation work Document creation, drawing, imaging, scheduling and productivity software development services Air filters Control, safety or signalling equipment for port installations Dry goods Command, control, communication and computer systems Modules Microprocessors Shelter parts Counters System, storage and content management software development services Towers Boxes Rings, seals, bands, sticks and grout packers Dampers Laboratory, hygienic or pharmaceutical glassware Sheets Monitors Bars, rods, wire and profiles used in construction Pressure-reducing, control, check or safety valves Sheeting work Other services Panels Strip Cable, wire and related products Steel Bars Seats, chairs and related products, and associated parts Control, safety or signalling equipment for roads Goods used in construction Architectural, construction, engineering and inspection services Poles Miscellaneous cordage, rope, twine and netting Lamps Rope Cable TV Radio, television, communication, telecommunication and related equipment Designs Anchors Conductors Cable accessories Control, safety or signalling equipment for airports Plates, sheets, strip and foil related to construction materials Dates Fuses, caps, igniters and electric detonators
UNSPSC
Netting Busses Plate Insulation Shelter Ropes Bolts Anchors Clamps Tape Rectifiers Inverters Fans Air conditioners Drain Filters Air filters Counters pH meters Q Meters Software Templates Boards Awards Water Radios Distribution Bars Connectors Equipment cases Charcoal Personal communication holders or mounts, stands Control unit Single room Case making services Two way radios Side pole Refrigerant Area lighting Coffee, green Boxes Water, sanitation and hygiene kits Water, sanitation and hygiene kit Direction Finding Equipment, Accessories Water, sanitation and hygiene kits Humanitarian Relief Items, Kits, or Accessories
Regions
Asia SAARC Countries South Asia
Sectors
Civil Works Building Environment and Pollution-Recycling Automobiles and Auto Parts Non-Renewable Energy Supply Solar Photovoltaic PV Energy Stainless Steel and Galvanized Light and Lighting Products Postal and Courier Services Roads and Highways-Bridge Infrastructure Telecommunications Water and Sanitation Law and Legal Printing and Publishing Services Information Technology-IT Defence and Security Electricity Technology Hardware and Equipment Construction Energy-Power and Electrical Computer Hardwares and Consumables Steel Industry Laboratory Equipment and Services Aviation Building Material Marine
URL
Share
To be notified
when a tender matching your filter is published
To Follow
Tenders
Add New Tender Alert
To Follow
Contracts
Add New Contract Alert