Sign up now to have the right to view
50 tenders for free.
Title |
Low Dose Weight-Bearing Computed Tomography Scanner |
|||
---|---|---|---|---|
You can sign up and unlock it for freeAccess to Public and Private Sector Business Opportunities for 200+ Countries |
||||
Country | ||||
Language | English | |||
Organization | ||||
Published Date | 03.10.2024 | |||
Deadline Date | 31.10.2024 | |||
Overview |
University of Ottawa Low Dose Weight-Bearing Computed Tomography Scanner Low Dose Weight-bearing Computed Tomography Scanner - 43177-3A-RFP | PhoneCall Us: (800) 964-6379 / (613) 727-4900 Canadian Tenders U.S. Tenders Private Construction Offering Pricing Buyers 43177-3A-RFP - Low Dose Weight-Bearing Computed Tomography Scanner 43177-3A-RFP - Low Dose Weight-Bearing Computed Tomography Scanner (11) 11 Print Share Basic Information Reference Number 0000279587 Issuing Organization University of Ottawa Owner Organization University of Ottawa Solicitation Type RFP - Request for Proposal (Formal) Solicitation Number 43177-3A-RFP Title Low Dose Weight-Bearing Computed Tomography Scanner Source ID PU.AC.ON.11752.C110155 Agreement Types Broader Public Sector (BPS) Canada-European Union Comprehensive Economic and Trade Agreement(CETA) Canadian Free Trade Agreement (CFTA) Details Location Canada, Ontario, Ottawa Delivery Point University of Ottawa Purchase Type One Time Only- Delivery Date:2025/03/28 Description Scope of Project: Cone beam computed tomography (CT) scanners enable internal volumetric imaging of the extremities in weight bearing and non-weight bearing configurations. Three-dimensional imaging of bones with lower radiation doses than traditional CT is performed using a rotating cone beam X-ray. Configurable systems enable imaging of various joints of the upper and lower extremities. General Description: The weight bearing CT scanner will be used to visualize the bony geometry in the joints of the upper and lower extremities, with the knee joint of particular interest. Images will also be segmented to produce 3D models of joint geometry for further analyses and to develop personalized computational models. For this, export to Digital Imaging and Communications in Medicine (DICOM) format for use with typical segmentation software (e.g., Materialise Mimics, 3D Slicer) is necessary. A key use of the equipment will be to produce images for tracking biplanar videoradiography data. Therefore, the resolution of a pixel size of at least 0.5 mm and a slice thickness of at most 0.625 mm is required (Welte et al., 2022, doi:10.3791/63535) to allow for natural standing during imaging and reduce radiation dose to the participants when scanning both lower limbs, the ability to perform bilateral scans of the lower extremities is required. Mandatory Requirements: 1. Weightbearing CT Scanner: 1.1 Must fit in a 3x3 m footprint. 1.2 Must be capable of producing scans with an in plane resolution of 0.5 mm or less and a slice thickness of 0.625 mm or less. 1.3 Must be able to scan the hands, wrists, and elbows. 1.4 Must be able perform weight bearing scans of the ankles, knees, and hip. 1.5 Must be capable of bilateral scans of the lower extremities. 1.6 Must provide a desktop computer capable of runing the system and software. All required peripherals (keyboard, mouse, etc) must also be included. 2. Software: 2.1 Must enable visualization of images in all three planes. 2.2 Must be able to export images to DICOM format. 3. Other Requirements: 3.1 Installation and training must be included. 3.2 Must include a minimum of one (1) year warranty on parts and labour. Dates Publication 2024/10/03 01:58:08 PM EDT Bid Intent Not Available Question Acceptance Deadline 2024/10/17 03:00:00 PM EDT Questions are submitted online Yes Closing Date 2024/10/31 03:00:00 PM EDT Contact Information Owen Bouley 613-562-5800 ext. 3966 obouley@uottawa.ca Buyer Preferences, Guidelines & Requirements General Requirements - Certification/Training - Installation Required - Insurance Required - Training Required - Warranty Information Required Bid Submission Process Bid Submission Type Electronic Bid Submission Pricing
|
|||
NAICS | ||||
CPVS |
Elbows
System, storage and content management software package
Scanners
CT scanners
Construction, foundation and surface works for highways, roads
Publications
Wells construction work
Training, workout or aerobic services
Parts of computers
Feasibility study, advisory service, analysis
Document creation, drawing, imaging, scheduling and productivity software package
Construction work
Document creation, drawing, imaging, scheduling and productivity software development services
System, storage and content management software development services
Bearings
Machine tools for working wood, bone, cork, hard rubber or hard plastics
Keys
Goods used in construction
Architectural, construction, engineering and inspection services
Beams
Radio, television, communication, telecommunication and related equipment
Electronic, electromechanical and electrotechnical supplies
Dates
Tools, locks, keys, hinges, fasteners, chain and springs
|
|||
UNSPSC | ||||
Regions | ||||
Sectors |
Civil Works
Healthcare and Medicine
Environment and Pollution-Recycling
Automobiles and Auto Parts
Non-Renewable Energy
Solar Photovoltaic PV Energy
Bridges and Tunnels
Banking-Finance-Insurance
Postal and Courier Services
Roads and Highways-Bridge
Law and Legal
Printing and Publishing
Railways-Rail-Railroad
Information Technology-IT
Education and Training
Defence and Security
Electricity
Construction
Energy-Power and Electrical
Computer Hardwares and Consumables
Steel
Electronics
Marine
|
|||
URL | ||||
Share |
Title |
---|
Low Dose Weight-Bearing Computed Tomography Scanner |
Country |
Language |
English |
Organization |
Published Date |
03.10.2024 |
Deadline Date |
31.10.2024 |
Overview |
University of Ottawa Low Dose Weight-Bearing Computed Tomography Scanner Low Dose Weight-bearing Computed Tomography Scanner - 43177-3A-RFP | PhoneCall Us: (800) 964-6379 / (613) 727-4900 Canadian Tenders U.S. Tenders Private Construction Offering Pricing Buyers 43177-3A-RFP - Low Dose Weight-Bearing Computed Tomography Scanner 43177-3A-RFP - Low Dose Weight-Bearing Computed Tomography Scanner (11) 11 Print Share Basic Information Reference Number 0000279587 Issuing Organization University of Ottawa Owner Organization University of Ottawa Solicitation Type RFP - Request for Proposal (Formal) Solicitation Number 43177-3A-RFP Title Low Dose Weight-Bearing Computed Tomography Scanner Source ID PU.AC.ON.11752.C110155 Agreement Types Broader Public Sector (BPS) Canada-European Union Comprehensive Economic and Trade Agreement(CETA) Canadian Free Trade Agreement (CFTA) Details Location Canada, Ontario, Ottawa Delivery Point University of Ottawa Purchase Type One Time Only- Delivery Date:2025/03/28 Description Scope of Project: Cone beam computed tomography (CT) scanners enable internal volumetric imaging of the extremities in weight bearing and non-weight bearing configurations. Three-dimensional imaging of bones with lower radiation doses than traditional CT is performed using a rotating cone beam X-ray. Configurable systems enable imaging of various joints of the upper and lower extremities. General Description: The weight bearing CT scanner will be used to visualize the bony geometry in the joints of the upper and lower extremities, with the knee joint of particular interest. Images will also be segmented to produce 3D models of joint geometry for further analyses and to develop personalized computational models. For this, export to Digital Imaging and Communications in Medicine (DICOM) format for use with typical segmentation software (e.g., Materialise Mimics, 3D Slicer) is necessary. A key use of the equipment will be to produce images for tracking biplanar videoradiography data. Therefore, the resolution of a pixel size of at least 0.5 mm and a slice thickness of at most 0.625 mm is required (Welte et al., 2022, doi:10.3791/63535) to allow for natural standing during imaging and reduce radiation dose to the participants when scanning both lower limbs, the ability to perform bilateral scans of the lower extremities is required. Mandatory Requirements: 1. Weightbearing CT Scanner: 1.1 Must fit in a 3x3 m footprint. 1.2 Must be capable of producing scans with an in plane resolution of 0.5 mm or less and a slice thickness of 0.625 mm or less. 1.3 Must be able to scan the hands, wrists, and elbows. 1.4 Must be able perform weight bearing scans of the ankles, knees, and hip. 1.5 Must be capable of bilateral scans of the lower extremities. 1.6 Must provide a desktop computer capable of runing the system and software. All required peripherals (keyboard, mouse, etc) must also be included. 2. Software: 2.1 Must enable visualization of images in all three planes. 2.2 Must be able to export images to DICOM format. 3. Other Requirements: 3.1 Installation and training must be included. 3.2 Must include a minimum of one (1) year warranty on parts and labour. Dates Publication 2024/10/03 01:58:08 PM EDT Bid Intent Not Available Question Acceptance Deadline 2024/10/17 03:00:00 PM EDT Questions are submitted online Yes Closing Date 2024/10/31 03:00:00 PM EDT Contact Information Owen Bouley 613-562-5800 ext. 3966 obouley@uottawa.ca Buyer Preferences, Guidelines & Requirements General Requirements - Certification/Training - Installation Required - Insurance Required - Training Required - Warranty Information Required Bid Submission Process Bid Submission Type Electronic Bid Submission Pricing |
NAICS |
Cut Stock Justice Justice Construction Other Justice Machinery Colleges Colleges Agriculture Colleges Other Justice Construction Process |
CPVS |
Elbows System, storage and content management software package Scanners CT scanners Construction, foundation and surface works for highways, roads Publications Wells construction work Training, workout or aerobic services Parts of computers Feasibility study, advisory service, analysis Document creation, drawing, imaging, scheduling and productivity software package Construction work Document creation, drawing, imaging, scheduling and productivity software development services System, storage and content management software development services Bearings Machine tools for working wood, bone, cork, hard rubber or hard plastics Keys Goods used in construction Architectural, construction, engineering and inspection services Beams Radio, television, communication, telecommunication and related equipment Electronic, electromechanical and electrotechnical supplies Dates Tools, locks, keys, hinges, fasteners, chain and springs |
UNSPSC |
Beams Bearings Keyboards Scanners Software Trade agreements Equipment cases University High Frequency Radio Set, Desktop Very High Frequency Radio Set, Desktop Training, Technical: Crew Resource Management, Emergency Procedures, Dangerous Goods |
Regions |
APEC Countries North America Northern America |
Sectors |
Civil Works Healthcare and Medicine Environment and Pollution-Recycling Automobiles and Auto Parts Non-Renewable Energy Solar Photovoltaic PV Energy Bridges and Tunnels Banking-Finance-Insurance Postal and Courier Services Roads and Highways-Bridge Law and Legal Printing and Publishing Railways-Rail-Railroad Information Technology-IT Education and Training Defence and Security Electricity Construction Energy-Power and Electrical Computer Hardwares and Consumables Steel Electronics Marine |
URL |
Share |
To be notified
when a tender matching your filter is
published
To Follow
Tenders
Add New Tender Alert
To Follow
Contracts
Add New Contract Alert
To Follow
Fairs
Add New Fair Alert
Similar Tenders