Tender Details
Title

(RE-12190)NBI電源用コンデンサ取外し作業【掲載期間:2024-10-04~2024-10-24】 (RE-12190)NBI電源用コンデンサ取外し作業【掲載期間:2024-10-04~2024-10-24】 公告期間: ~()に付します。 1.競争入札に付する事項RE-12190仕様書のとおり2.... (RE-12190) Removal of capacitor for NBI power supply [Posting period: 2024-10-04 to 2024-10-24] (RE-12190) Removal of capacitor for NBI power supply [Posting period: 2024-10-04 to 2024-10-24] Announcement period: ~ (). 1. Items to be submitted for competitive bidding As per RE-12190 specifications 2. ...

Country
Language
Japanese
Organization
Published Date
04.10.2024
Deadline Date
05.01.2025
Overview
(RE-12190)NBI電源用コンデンサ取外し作業【掲載期間:2024-10-04~2024-10-24】 (RE-12190)NBI電源用コンデンサ取外し作業【掲載期間:2024-10-04~2024-10-24】 公告期間: ~()に付します。 1.競争入札に付する事項RE-12190仕様書のとおり2.... 国立研究開発法人量子科学技術研究開発機構核融合エネルギー研究開発部門那珂核融合研究所  茨城県那珂市 入札情報は以下の通りです。 件名 (RE-12190)NBI電源用コンデンサ取外し作業【掲載期間:2024-10-04~2024-10-24】 入札区分 一般競争入札 公示日または更新日 2024 年 10 月 4 日 組織 国立研究開発法人量子科学技術研究開発機構 取得日 2024 年 10 月 4 日 19:55:38 仕様書 [PDFファイル/1.15MB] 公告内容 公告期間: ~()に付します。 1.競争入札に付する事項RE-12190仕様書のとおり2.入札書等の提出場所等入札説明書等の交付場所及び問い合わせ先(ダイヤルイン)入札説明書等の交付方法上記2.(1)に記載の交付場所または電子メールにより交付する。 ただし、交付は土曜,日曜,祝日及び年末年始(12月29日~1月3日)を除く平日に行う。 電子メールでの交付希望の場合は、「 公告日,契約管理番号,入札件名,当機構担当者名,貴社名,住所,担当者所属,氏名,電話,FAX,E-Mail 」を記載し、上記2.(1)のアドレスに送信。 交付の受付期限は 17:00までとする。 入札説明会の日時及び場所入札及び開札の日時並びに場所R6.10.24(4)実施しない管理部契約課管理研究棟1階 入札室(114号室) 那珂フュージョン科学技術研究所(4)R6.10.4茨城県那珂市向山801番地1(3)記(1)下記のとおり〒311-0193E-mail:TEL(2)(3)(1)契約管理番号nyuusatsu_naka@qst.go.jp那珂フュージョン科学技術研究所15時30分請負令和6年10月4日NBI電源用コンデンサ取外し作業令和7年1月31日029-210-2391履行場所履行期限一般競争入札入 札 公 告 (郵便入札可)(火)茨城県那珂市向山801番地1管理部長那珂フュージョン科学技術研究所国立研究開発法人量子科学技術研究開発機構(木) 令和6年10月24日滝口 健二国立研究開発法人 量子科学技術研究開発機構 那珂フュージョン科学技術研究所令和6年11月12日松田 好広FAX 050-3730-8549(2)件名内容(5)3.競争に参加する者に必要な資格当機構から指名停止措置を受けている期間中の者でないこと。 全省庁統一競争入札参加資格を有する者であること。 当機構が別に指定する誓約書に暴力団等に該当しない旨の誓約をできること。 4.入札保証金及び契約保証金 免除5.入札の無効入札参加に必要な資格のない者のした入札入札の条件に違反した者の入札6.契約書等作成の要否7.落札者の決定方法8.その他その他、詳細については、入札説明書によるため、必ず上記2.(2)により、 入札説明書の交付を受けること。 本入札に関しての質問書は、 15:00までに上記問い合わせ先宛てに提出すること。 なお、質問に対する回答は、 中に当機構ホームページにおいて掲載する。 本件以外にも、当機構ホームページ(調達情報)において、今後の「調達予定情報」を掲載していますのでご確認ください。 (掲載箇所URL:https://www.qst.go.jp/site/procurement/)以上 公告する。 本契約締結にあたっては、当機構の定める契約書(契約金額が500万円以上の場合)もしくは請書(契約金額が200万円以上500万円未満の場合)を作成するものとする。 (木) 令和6年10月17日令和6年10月10日 (木)(1)この入札に参加を希望する者は、参考見積書等の提出時に、当機構が別に指定する暴力団等に該当しない旨の誓約書を提出しなければならない。 予定価格の制限の範囲内で、最低価格をもって有効な入札を行った入札者を落札者とする。 (最低価格落札方式)(1)(5)(4)(2)(3)前項の誓約書を提出せず、又は虚偽の誓約をし、若しくは誓約書に反することとなったときは、当該者の入札を無効とするものとする。 国立研究開発法人量子科学技術研究開発機構 契約事務取扱細則第11条第1項の規定に該当しない者であること。 (5)国立研究開発法人量子科学技術研究開発機構 契約事務取扱細則第10条の規定に該当しない者であること。ただし、未成年者、被保佐人又は被補助人であって、契約締結のために必要な同意を得ている者についてはこの限りでない。 (2) 落札決定に当っては、入札書に記載した金額に当該金額の10パーセントに相当する額を加算した金額(当該金額に1円未満の端数があるときは、その端数を切り捨てた金額とする)をもって落札価格とするので、入札者は、消費税に係る課税事業者であるか免税事業者であるかを問わず、見積もった金額の110分の100に相当する金額を入札書に記載すること。 NBI電源用コンデンサ取外し作業仕様書国立研究開発法人量子科学技術研究開発機構那珂フュージョン科学技術研究所ITERプロジェクト部 NB加熱開発グループ- 1 -1. 件名NBI電源用コンデンサ取外し作業2. 目的及び概要本件は、国立研究開発法人量子科学技術研究開発機構(以下「量研」という。)那珂フュージョン科学技術研究所の中性粒子入射加熱装置(以下「NBI」という。)の電源で使用している低濃度PCB汚染コンデンサ等を取外し、保管するものである。本件の対象機器は、内部の絶縁油が低濃度 PCB 汚染の恐れがあるコンデンサ等である。従って、その取り扱いには細心の注意を払って電源盤等からの取外し作業を行うこと。PCB含有が確認された絶縁油を使用した機器については、廃棄物の処理及び清掃に関する法律(以下「廃棄物処理法」という。)やポリ塩化ビフェニル廃棄物の適正な処理の推進に関する特別措置法(以下「PCB特対策法」という。)等に基づき期限までに適切に処分することが義務付けられている。その対応の一環で本件を実施するものである。3. 作業実施場所量研 那珂フュージョン科学技術研究所内の以下の場所及びその周辺とする。図1に建屋配置を示す。図2~5に主なコンデンサ設置場所を示す。・JT-60実験棟 地下1階RV室(Ⅰ)・PIG電源室 ※放射線管理区域・JT-60実験棟 増築部RV室(Ⅱ)・N-NBI電源室・JT-60加熱電源棟 トランスヤード ※屋外・JT-60高圧ガス機械棟 コンプレッサー室4. 納期令和7年1月31日5. 作業実施期間作業期間は、別途量研と受注者の間で協議を行い決定する。6. 対象機器本件の対象となるコンデンサを表1に示す。7. 作業内容(1) 作業実施場所に、必要に応じて絶縁油漏洩防止のための養生を施すこと。当該養生は作業終了後に撤去すること。- 2 -(2) 対象機器を JT-60 実験棟他のコンデンサ設置場所から取外し、量研担当者が指定する場所へ運搬・保管すること。(3) 対象機器を電源盤等から取外す際は、ケーブル離線・固定ネジ等の撤去などコンデンサ取外しに必要な作業を行うこと。コンデンサに接続されている配線は切断しても良いが、コンデンサ後継機種を再取付けする際を考慮して適切な位置で切断すること。配線切断位置は事前に量研担当者の確認を受けること。また、コンデンサ固定ネジ等についてもコンデンサ後継機種を再取付けする際を考慮して、取外した固定ネジ等をビニール袋等に入れて、当該電源盤等の容易に分かる場所に明示して保管すること。8. 支給品及び貸与品8.1 支給品作業場所において必要となる電気及び水は、容量の範囲内で無償にて支給する。詳細は量研との協議による。8.2 貸与品対象機器の運搬にあたり、量研が所有するエンジン式のフォークリフトは無償にて貸与する。 ただし、屋外での使用に限る。なお、使用者はフォークリフトの作業を行うために必要な免許を所有していることとし、作業前に免許証の提示と必要な所内手続きを行うこと。また、他の作業で使用する可能性があるため、使用にあたっては事前に使用日時の調整を行うこと。9. 提出書類受注者は、下記に示す提出書類を遅滞なく提出すること。また、※印の付いている書類については電子ファイルをCD-R又はDVD-Rに記録し、納入時に提出すること。提出書類の種類 提出期限 提出部数 確認総括責任者届 契約締結後速やかに 1部 要作業従事者名簿【注】 契約締結後速やかに 1部 要作業工程表(※) 契約締結後速やかに 1部 要作業要領書(※) 契約締結後速やかに 2部 要作業報告書(※) 作業終了後速やかに 2部 不要- 3 -【注】外国籍の者の入構、また、日本国籍の非居住者の入構がある場合は、入構する 2 週間前までに量研担当者に外国人来訪者票を提出すること。(提出場所)那珂フュージョン科学技術研究所 JT-60制御棟 408号室(確認方法)「確認」は次の方法で行う。量研は、確認のために提出された書類を受領したときは、期限日を記載した受領印を押印して返却する。また、当該期限までに審査を完了し、受理しない場合には修正を指示し、修正等を指示しないときは、受理したものとする。この確認は、確認が必要な書類 1部をもって行うものとし、受注者は、量研の確認後、残りの書類のコピーを量研へ送付するものとする。ただし、再委託承諾願については、量研が確認後、書面にて回答するものとする。10. 検査条件貸与品が返却されたこと及び提出書類が提出されたことが確認され、仕様書の定めるところに従って作業が実施されたと量研が認めたときをもって検査合格とする。11. 関係法令以下の関係法令等を遵守するものとする。(1) 廃棄物処理法(2) PCB特別措置法(3) 労働基準法(4) 労働安全衛生法(5) 電気事業法(6) 放射線同位元素等規制法(7) その他の関係法令、規程、基準等(8) 量研内の諸規程・諸規則12. 特記事項(1) 一般安全再委託承諾願※量研指定様式を用いること。業務の一部を第三者に委任し、又は請け負わせようとするときは、作業開始前までに提出すること。 また、再委託の内容を変更する場合は、速やかに提出すること。1部 要その他量研が必要とする書類 その都度(詳細は別途協議) 必要部数協議の上、決定する。- 4 -① 受注者は量研が量子科学技術の研究・開発を行う機関であるため高い技術力及び高い信頼性を社会的に求められていることを認識し、量研の規程等を遵守し安全性に配慮し業務を遂行し得る能力を有する者を従事させること。② 受注者は業務を実施することにより取得した当該業務及び作業に関する各データ、技術情報、成果その他の全ての資料及び情報を量研の施設外に持ち出して発表若しくは公開し又は特定の第三者に対価を受け、若しくは無償で提供することはできない。ただし、あらかじめ書面により量研の承認を受けた場合はこの限りではない。③ 異常事態等が発生した場合、受注者は量研の指示に従い行動するものとする。④ 受注者は、安全関係法令及び量研の諸規程を遵守し、安全について万全の注意を払うとともに量研の安全管理担当者の指示に従うこと。⑤ 受注者は本作業を行うに際し、同時に行われる他の作業と協調を図り作業工程を調整すること。⑥ 作業で使用する養生材等は受注者が用意すること。⑦ 受注者は、作業責任者及びその代理者を指名し、作業内容及び作業中の安全について、事前に量研と十分な打合せを行った後、作業に着手すること。⑧ 受注者は、作業現場の見やすい位置に、作業責任者名及び連絡先等を表示すること。⑨ 作業中は、常に整理整頓を心掛ける等、安全及び衛生面に十分留意すること。(2) 放射線管理① 受注者は、放射線管理区域内で作業を行う場合は、量研が定める那珂研究所放射線障害予防規程及び那珂研究所放射線取扱手引を遵守しなければならない。② 放射線管理区域内に立入る作業を行う場合は、作業を開始する前に、受注者側作業員は、量研が行う保安教育を受けること。ただし、放射線に関する知識は、受注者側で教育すること。③ 放射線管理及び異常時の対策は、量研の指示に従うこと。13. 総括責任者受注者は本契約業務を履行するに当たり、受注者を代表して直接指揮命令する者(以下「総括責任者」という。)を選任し、次の任務に当たらせるものとする。(1) 受注者の従事者の労務管理及び作業上の指揮命令(2) 本契約業務履行に関する量研との連絡及び調整(3) 受注者の従事者の規律秩序の保持並びにその他本契約業務の処理に関する事項14. グリーン購入法の推進(1) 本契約において、グリーン購入法(国等による環境物品等の調達の推進等に関する法律)に適用する環境物品(事務用品、OA機器等)が発生する場合は、これを採用するものとする。(2) 本仕様に定める提出書類(納入印刷物)については、グリーン購入法の基本方針に定める- 5 -「紙類」の基準を満たしたものであること。15. 協議本仕様書に記載されている事項及び本仕様書に記載のない事項について疑義が生じた場合は、量研と協議の上、その決定に従うものとする。以上- 6 -図1.建屋配置図- 7 -図2.JT-60実験棟 地下1階- 8 -図3.JT-60実験棟 増築部- 9 -図4.JT-60加熱電源棟- 10 -図5. JT-60高圧ガス機械棟- 11 -表1 作業対象コンデンサの一覧表No. メーカー 型番 製造年サイズW×D×H(cm)重量/台(kg)数量(台)盤名 作業場所1マルコン電子 CP701C3A504K 1984年 4×2×5 0.1 1320 HVT2 JT-60実験棟PIG電源室2マルコン電子 MP CAPACITOR_16MWK106A 1984年 4×2×7 0.2 220 HVT2 JT-60実験棟PIG電源室3マルコン電子 CP701C3A504K 1984年 4×2×5 0.1 26 打消コイル電源 JT-60加熱電源棟 直流フィルタ室4マルコン電子 CP701C3A104K 1984年 4×2×5 0.1 162 打消コイル電源 JT-61加熱電源棟 直流フィルタ室5マルコン電子 MP CAPACITOR_50MWK106K 1984年 5×3×5 0.2 81 HVT2 JT-60実験棟PIG電源室6日新電機 MEU-CK 1984年 50×20×50 99 24 特高限流リアクトル盤 JT-60加熱電源棟トランスヤード7ニチコン㈱ EB252301DXC374 1984年 45×15×40 30 13 減速電源盤 JT-60実験棟RV室Ⅰ・RV室Ⅱ8マルコン電子 NLP-4200KPR 1984年 23×7×25 5 26 HVT2 JT-60実験棟PIG電源室9マルコン電子 FB-1067 1984年 20×5×15 3.3 26 打消コイル電源 JT-60実験棟PIG電源室10ニチコン㈱ DIV-200K、400K、500K 1994年 40×25×50 40 3 電流計測装置 JT-60実験棟N-NBI電源室11ニチコン㈱ SEF-60003TN 1983年 45×20×40 16 4 受配電盤 高圧ガス機械棟 (RE-12190) Removal of capacitors for NBI power supply [Posting period: 2024-10-04 to 2024-10-24] (RE-12190) Removal of capacitors for NBI power supply [Posting period: 2024-10-04 to 2024-10-24] Announcement period: Attached to (). 1. Items to be submitted for competitive bidding As per RE-12190 specifications 2. ... National Research and Development Agency National Institutes for Quantum and Radiological Science and Technology Fusion Energy Research and Development Department Naka Fusion Institute Naka City, Ibaraki Prefecture Bidding information is as follows. Subject (RE-12190) Removal of capacitors for NBI power supply [Posting period: 2024-10-04 to 2024-10-24] Bidding category Public competitive bidding Date of announcement or update October 4, 2024 Organization National Institutes for Quantum and Radiological Science and Technology Date of acquisition October 4, 2024 19:55:38 Specifications [PDF file / 1.15MB] Announcement content Announcement period: Attached to (). 1. Items to be attached to competitive bidding As per RE-12190 specifications 2. Place of submission of bid documents, etc. Place of delivery of bid documents, etc. and contact information (dial-in) Method of delivery of bid documents, etc. Delivered at the delivery place described in 2. (1) above or by email. However, delivery will be made on weekdays excluding Saturdays, Sundays, holidays, and the New Year holidays (December 29th to January 3rd). If you wish to receive the document by e-mail, please write the following information and send it to the address in 2. (1) above. The deadline for receiving the document is 17:00. Date and time of the bid briefing and location Date and time of the bid and bid opening October 24, 1984 (4) Not implemented Management Department Contract Division Management Research Building 1st floor Bidding Room (Room 114) Naka Fusion Science and Technology Research Institute (4) October 4, 1984 801-1 Mukaiyama, Naka City, Ibaraki Prefecture (3) Details (1) As follows 〒311-0193 E-mail: TEL (2) (3) (1) Contract management number nyuusatsu_naka@qst.go.jp Naka Fusion Science and Technology Research Institute 15:30 Contract October 4, 2024 Removal of capacitors for NBI power supply January 31, 2025 029-210-2391 Place of performance Performance deadline Public competitive bidding Bidding announcement (Bids by post accepted) (Tue) 801-1 Mukaiyama, Naka, Ibaraki Prefecture Manager of Administration Naka Fusion Science and Technology Institute National Research and Development Agency Quantum and Radiological Science and Technology (Thu) October 24, 2024 Kenji Takiguchi Naka Fusion Science and Technology Institute, National Research and Development Agency Quantum and Radiological Science and Technology November 12, 2024 Yoshihiro Matsuda Fax 050-3730-8549 (2) Subject Content (5) 3. Qualifications required for participants in the competition Not be a person currently subject to a suspension of nomination by the Agency. A person who is qualified to participate in unified competitive bidding for all ministries and agencies. Able to pledge in a separate pledge specified by the Agency that they are not affiliated with organized crime groups, etc. 4. Exemption from bid security and contract security 5. Invalidated bids Bids made by persons without the necessary qualifications to participate in bids Bids made by persons who violate the conditions of the bid 6. Whether or not contracts, etc. must be prepared 7. Method for determining the successful bidder 8. Other For details, please refer to the bidding instructions, so be sure to receive the bidding instructions as described in 2. (2) above. Questions regarding this bidding should be submitted to the above contact by 15:00. The answers to your questions will be posted on our website during the period. In addition to this matter, please check our website (Procurement Information) for future "Procurement Plan Information." (URL: https://www.qst.go.jp/site/procurement/) The above is announced. When concluding this contract, a contract (if the contract amount is 5 million yen or more) or a receipt (if the contract amount is 2 million yen or more but less than 5 million yen) specified by our organization will be prepared. (Thu) October 17, 2024 October 10, 2024 (Thu) (1) Those who wish to participate in this bidding must submit a pledge that they are not affiliated with any organized crime group, etc., as separately designated by our organization, when submitting a reference estimate, etc. The successful bidder will be the bidder who submits a valid bid with the lowest price within the estimated price limit. (Lowest Price Bidding Method) (1)(5)(4)(2)(3) If a bidder fails to submit the pledge in the preceding paragraph, makes a false pledge, or violates the pledge, the bid of that bidder will be invalidated. The bidder must not fall under the provisions of Article 11, Paragraph 1 of the Detailed Rules for Handling Contract Affairs of the National Institutes for Quantum and Radiological Science and Technology. (5) The bidder must not fall under the provisions of Article 10 of the Detailed Rules for Handling Contract Affairs of the National Institutes for Quantum and Radiological Science and Technology. However, this does not apply to minors, persons under guardianship, or persons under assistance who have obtained the consent necessary to enter into a contract. (2) In determining the successful bid, the successful bid price will be the amount stated in the bid document plus 10% of the amount stated in the bid document (if the amount has a fraction of less than 1 yen, the fraction will be rounded down). Therefore, regardless of whether the bidder is a taxable or exempt business, the bidder must state in the bid document an amount equivalent to 110/100 of the estimated amount. NBI Power Supply Capacitor Removal Work Specifications National Institutes for Quantum and Radiological Science and Technology Naka Fusion Science and Technology Institute ITER Project Department NB Heating Development Group - 1 -1. Subject NBI Power Supply Capacitor Removal Work 2. Purpose and Overview This project involves removing and storing low-concentration PCB-contaminated capacitors and other items used in the power supply for the Neutral Beam Injection Heating Device (hereinafter referred to as "NBI") at the Naka Fusion Science and Technology Institute of the National Institutes for Quantum and Radiological Science and Technology (hereinafter referred to as "QST"). The equipment in question is capacitors and other items whose insulating oil may be contaminated with low-concentration PCBs. Therefore, they must be handled with the utmost care when removing them from power panels etc. Equipment that uses insulating oil confirmed to contain PCBs is required to be properly disposed of by a deadline in accordance with the Waste Disposal and Public Cleansing Act (hereinafter referred to as the "Waste Disposal Act") and the Act on Special Measures Concerning the Promotion of Proper Disposal of Polychlorinated Biphenyl Waste (hereinafter referred to as the "PCB Special Measures Act"). This project is being carried out as part of that response. 3. Location of Work The work will be carried out in the following locations and surrounding areas within the Naka Fusion Science and Technology Research Institute of QST. Figure 1 shows the layout of the buildings. Figures 2 to 5 show the locations where the main capacitors will be installed.・JT-60 Laboratory Building, 1st basement floor RV room (I) ・PIG power supply room *Radiation controlled area ・JT-60 Laboratory Building, extension RV room (II) ・N-NBI power supply room ・JT-60 heating power supply building transformer yard *Outdoors ・JT-60 high pressure gas machine building compressor room4. Delivery dateJanuary 31, 20255. Work implementation periodThe work period will be decided through separate discussions between QST and the contractor. 6. Target equipmentThe capacitors that are the subject of this project are shown in Table 1. 7.Work Contents (1) If necessary, provide protection at the work site to prevent leakage of insulating oil. The protection should be removed after the work is completed. - 2 -(2) Remove the target equipment from the capacitor installation site in the JT-60 laboratory building or other locations, and transport and store it at a location designated by the QST staff. (3) When removing the target equipment from the power supply panel, etc., perform the work required for removing the capacitor, such as disconnecting the cables and removing the fixing screws. The wiring connected to the capacitor may be cut, but it should be cut at an appropriate location, taking into consideration the reinstallation of the capacitor successor model. The wiring cut location should be confirmed in advance by the QST staff. In addition, the capacitor fixing screws, etc., should be placed in a plastic bag, etc., and stored in an easily visible place on the power supply panel, etc., taking into consideration the reinstallation of the capacitor successor model. 8. Supplies and Loan Items8.1 SuppliesElectricity and water required at the work site will be provided free of charge within the capacity. Details will be discussed with QST. 8.2 For the transportation of the loaned equipment, an engine-powered forklift owned by QST will be loaned free of charge. However, this is limited to outdoor use. Users must possess the necessary license to operate a forklift, and must present the license and complete the necessary internal procedures before starting work. In addition, since the forklift may be used for other work, the date and time of use must be arranged in advance. 9. Documents to be submitted The contractor must submit the documents listed below without delay. In addition, documents marked with an asterisk must be recorded as electronic files on a CD-R or DVD-R and submitted at the time of delivery. Type of document to be submitted Deadline for submission Number of copies to be submitted Notification of confirmation general manager Immediately after contract is concluded 1 copy List of workers to be required [Note] Immediately after contract is concluded 1 copy Work schedule to be required (※) Immediately after contract is concluded 1 copy Work instructions to be required (※) Immediately after contract is concluded 2 copies Work report to be required (※) Immediately after work is completed 2 copies Not required - 3 - [Note] If a foreign national or a non-resident of Japanese nationality is entering the premises, a foreign visitor's card must be submitted to the QST staff at least 2 weeks prior to entering the premises. (Place of submission) Room 408, JT-60 Control Building, Naka Fusion Science and Technology Research Institute (Method of confirmation) "Confirmation" is carried out in the following manner. When QST receives documents submitted for confirmation, it will return them with a receipt stamp indicating the deadline. In addition, if the review is completed by the deadline and the documents are not accepted, corrections will be instructed, and if no corrections are instructed, the documents will be considered accepted. This confirmation shall be made using one copy of the documents that require confirmation, and the Contractor shall send copies of the remaining documents to QST after confirmation by QST. However, for the Subcontractor Acceptance Request, QST shall respond in writing after confirmation. 10. Inspection Conditions The inspection shall be considered as passed when QST confirms that the loaned items have been returned and the submitted documents have been submitted, and that the work has been carried out in accordance with the specifications. 11. Relevant Laws The following relevant laws and regulations shall be observed. (1) Waste Disposal Act (2) PCB Special Measures Act (3) Labor Standards Act (4) Industrial Safety and Health Act (5) Electricity Business Act (6) Radioisotope Regulation Act (7) Other relevant laws, regulations, standards, etc. (8) QST Rules and Regulations 12. Special Notes (1) General Safety Subcontractor Acceptance Request * Use the QST designated form. If you intend to delegate or subcontract part of the work to a third party, submit it before the start of work. In addition, if the contents of the subcontract are changed, they must be submitted promptly. 1 copy Other documents required by QST each time (details to be discussed separately) The number of copies required will be determined through discussion. - 4 -① The Contractor shall recognize that QST is an organization that conducts research and development of quantum science and technology, and therefore is socially required to have high technical capabilities and high reliability, and shall engage individuals who are capable of performing the work while complying with QST regulations, etc., and taking safety into consideration. ② The Contractor shall not take any data, technical information, results, or other materials and information related to the work and tasks obtained through the performance of the work outside the QST facilities, announce or disclose them, or provide them to a specific third party for compensation or free of charge. However, this does not apply if the Contractor has received prior written approval from QST. ③ In the event of an abnormality, etc., the Contractor shall act in accordance with QST's instructions. ④ The Contractor shall comply with safety-related laws and regulations and QST regulations, take all possible precautions regarding safety, and follow the instructions of the QST safety management officer. ⑤ When carrying out this work, the contractor shall coordinate the work schedule in coordination with other work being carried out at the same time. ⑥ The contractor shall prepare protective materials to be used in the work. ⑦ The contractor shall appoint a work manager and his/her representative, and shall begin the work after holding sufficient prior discussions with QST regarding the work content and safety during the work. ⑧ The contractor shall display the name of the work manager and contact information in a conspicuous location at the work site. ⑨ While working, the contractor shall pay close attention to safety and hygiene, such as keeping the work tidy at all times. (2) Radiation control ① When the contractor works within a radiation controlled area, the contractor shall comply with the Naka Institute Radiation Hazard Prevention Regulations and Naka Institute Radiation Handling Manual established by QST. ② When working within a radiation controlled area, the contractor's workers shall receive safety training provided by QST before starting the work. However, the contractor shall provide knowledge about radiation. ③ The contractor shall follow QST's instructions regarding radiation control and measures to be taken in the event of an abnormality. 13. General Manager The Contractor shall appoint a person (hereinafter referred to as the "General Manager") who will directly command and direct the Contractor in carrying out the work under this contract, and have him/her carry out the following duties. (1) Labor management and work command for the Contractor's employees (2) Communication and coordination with QST regarding the performance of the work under this contract (3) Maintenance of discipline and order among the Contractor's employees and other matters related to the processing of the work under this contract 14. Promotion of the Green Purchasing Act (1) In this contract, if environmentally friendly goods (office supplies, office equipment, etc.) that are applicable to the Green Purchasing Act (Act on the Promotion of Procurement of Environmental Goods, etc. by the State, etc.) are generated, they shall be adopted. (2) The documents to be submitted (delivered printed materials) specified in this specification shall meet the standards for "paper" specified in the basic policy of the Green Purchasing Act - 5 -. 15. Discussion If any doubts arise regarding matters described in this specification or matters not described in this specification, the decision shall be made after consultation with QST.End- 6 -Figure 1. Building layout- 7 -Figure 2. JT-60 Laboratory Building, 1st basement floor- 8 -Figure 3. JT-60 Laboratory Building, extension- 9 -Figure 4. JT-60 heating power supply building- 10 -Figure 5. JT-60 high pressure gas machinery building- 11 -Table 1 List of capacitors to be worked onNo. Manufacturer Model number Year of manufacture Size W x D x H (cm) Weight/unit (kg) Quantity (units) Panel name Work location1 MARCON ELECTRONICS CP701C3A504K 1984 4 x 2 x 5 0.1 1320 HVT2 JT-60 Laboratory Building PIG power supply room2 MARCON ELECTRONICS MP CAPACITOR_16MWK106A 1984 4 x 2 x 7 0.2 220 HVT2 JT-60 Experimental Building PIG power supply room 3 MARCON ELECTRONICS CP701C3A504K 1984 4×2×5 0.1 26 Neutralizing coil power supply JT-60 Heating power supply building DC filter room 4 MARCON ELECTRONICS CP701C3A104K 1984 4×2×5 0.1 162 Neutralizing coil power supply JT-61 Heating power supply building DC filter room 5 MARCON ELECTRONICS MP CAPACITOR_50MWK106K 1984 5×3×5 0.2 81 HVT2 JT-60 Experimental Building PIG power supply room 6 Nissin Electric MEU-CK 1984 50×20×50 99 24 Extra-high current limiting reactor panel JT-60 Heating power supply building transformer yard 7 Nichicon Corporation EB252301DXC374 1984 45×15×40 30 13 Deceleration power supply panel JT-60 Laboratory Building RV Room I, RV Room II 8 MALCON ELECTRONICS NLP-4200KPR 1984 23×7×25 5 26 HVT2 JT-60 Laboratory Building PIG power supply room 9 MALCON ELECTRONICS FB-1067 1984 20×5×15 3.3 26 Negation coil power supply JT-60 Laboratory Building PIG power supply room 10 Nichicon Corporation DIV-200K, 400K, 500K 1994 40×25×50 40 3 Current measurement device JT-60 Laboratory Building N-NBI power supply room 11 Nichicon Corporation SEF-60003TN 1983 45×20×40 16 4 Distribution panel High pressure gas machinery building
NAICS
-
CPVS
-
UNSPSC
-
Regions
APEC Countries Asia Eastern Asia
Sectors
Environment and Pollution-Recycling Non-Renewable Energy Supply Security Services Bridges and Tunnels Engineering Energy Postal and Courier Services Oil and Gas Telecommunications Water and Sanitation Law and Legal Environmental Work Printing and Publishing Education and Training Machinery and Equipments-M&E Defence and Security Electricity Construction Energy-Power and Electrical Computer Hardwares and Consumables Electronics
URL
Share
To be notified
when a tender matching your filter is published
To Follow
Tenders
Add New Tender Alert
To Follow
Contracts
Add New Contract Alert
To Follow
Fairs
Add New Fair Alert
Similar Tenders
Language: Japanese
Deadline Date: 18.12.2024