Tender Details
Title

農業集落排水事業川小田処理区機械装置更新工事 農業集落排水事業川小田処理区機械装置更新工事 北広島町公告第57号次のとおり事後審査型一般競争入札を行うので、北広島町財務規則第86条の規定により公告する。 なお、本件は広島県電子入札等システム(以下... Agricultural village drainage project Kawaoda treatment area machinery renewal work Agricultural village drainage project Kawaoda treatment area machinery renewal work Kitahiroshima Town Announcement No. 57 We will hold a post-examination type open competitive bidding as follows, and we announce it in accordance with the provisions of Article 86 of the Kitahiroshima Town Financial Regulations. This matter will be submitted through the Hiroshima Prefecture Electronic Bidding System (hereinafter referred to as...

Country
Language
Japanese
Organization
Published Date
02.10.2024
Deadline Date
03.01.2025
Overview
農業集落排水事業川小田処理区機械装置更新工事 農業集落排水事業川小田処理区機械装置更新工事 北広島町公告第57号次のとおり事後審査型一般競争入札を行うので、北広島町財務規則第86条の規定により公告する。 なお、本件は広島県電子入札等システム(以下... 広島県北広島町   入札情報は以下の通りです。 件名 農業集落排水事業川小田処理区機械装置更新工事 種別 工事 公示日または更新日 2024 年 10 月 2 日 組織 広島県北広島町 取得日 2024 年 10 月 2 日 19:17:29 仕様書 公告内容 北広島町公告第57号次のとおり事後審査型一般競争入札を行うので、北広島町財務規則第86条の規定により公告する。 なお、本件は広島県電子入札等システム(以下「電子入札システム」という。)を利用して入札を行う電子入札案件であり、入札に関する手続きについては、北広島町電子入札実施要領(以下「要領」という。)に従って行わなければならない。 令和6年10月2日北広島町長 箕 野 博 司1.工 事 名 農業集落排水事業川小田処理区機械装置更新工事2.工事場所 北広島町川小田3.工 期 契約締結日の翌日から令和7年3月31日4.予定価格 24,091,000円(消費税及び地方消費税相当額を除く)5.工事概要 川小田処理区における機械装置の更新(機能強化)に係る工事【機械設備】・自動粗目スクリーン ・脱臭ファン ・破砕機 ・換気扇・原水ポンプ ・非常用エンジンポンプ ・水中攪拌ポンプ・散水ポンプ ・ばっ気ブロワ ・給気ファン【電気設備】・原水ポンプ槽水位計【機械設備】・2号中継ポンプ№2 ・6号中継ポンプ№1、26.本件工事の入札に参加するものに必要な資格(1) 技術要件以外の要件次に掲げる要件をすべて満たしていること。 なお、イ及びウの要件は、それぞれに特記してある場合を除き、アの業種についてのものとする。 ア 令和5・6年度の北広島町の入札参加資格を認定されていなければならない業種機械器具設置工事イ 認定された入札参加資格の経営事項審査の総合評定値アの資格の審査を申請した際に添付した経営事項審査の総合評定値通知書又は審査基準日がこれより後である経営事項審査の総合評定値通知書等による。 不要(2) 技術要件次に掲げる要件をすべて満たして、それに関する資料の提出ができること。 ウ 年間平均完成工事高アの資格の審査を申請した際に添付した経営事項審査の総合評定値通知書又は審査基準日がこれより後である経営事項審査の総合評定値通知書等による。 4に掲げる予定価格以上エ 建設業法第15条の許可(特定建設業許可)の要否 不要オ 建設業法第3条第1項の営業所の所在地 広島県内に主たる営業所又は営業所を有すること。 カ この公告の日から開札日までの間のいずれの日においても、北広島町から指名除外を受けていないこと。 必要キ 右欄に掲げる本件工事に係る設計業務等の受託者以外の者であって、かつ当該受託者と資本及び人事面において次に掲げる関係にある者でないこと。 (ア) 当該受託者の発行済株式総数の過半数を有する。 (イ) 代表権を有する役員が当該受託者の代表権を有する役員を兼ねている。 ク この公告の日から開札日までの間のいずれの日においても、建設業法第28条第3項又は第5項の規定による営業停止処分を受けていないこと。 必要ケ 会社更生法に基づいて更生手続開始の申立てがなされている者及び民事再生法に基づいて再生手続開始の申立てがなされている者については、手続開始の決定後、北広島町長が別に定める手続きに基づいて入札参加資格の再認定を受けていること。 必要コ 地方自治法施行令第167条の4に該当するものでないこと。必要ア 同種同規模工事の元請施工実績平成21年4月1日から令和6年10月1日(公告日の前日)までの間に完成検査を受けている右の種類かつ本工事と同規模以上の工事で元請人又は共同企業体の代表としての施工実績を有すること。 ※特定共同企業体又は経常共同企業体の構成員としての実績は、出資比率20パーセント以上のものに限る。 不要イ 配置技術者に係る要件次に掲げる要件を全て満たす監理技術者を専任で本件工事不要7.設計図書閲覧(1) 閲覧期間北広島町ホームページにおいて、令和6年10月2日から令和6年10月11日まで電子閲覧とする。 掲載場所:「事業者向け情報>入札情報>入札・公募情報>入札情報(一般競争入札)」また、電子閲覧できない場合は、令和6年10月2日(水)午前9時から令和6年10月11日(金)午後5時まで(休日及び午後5時から午前9時までを除く。)北広島町環境生活課において紙による閲覧とする。 (2) 質問書提出期限令和6年10月8日(火)午後5時までには北広島町環境生活課に電子メールで提出すること。 (3) 回答書送付期間北広島町環境生活課において、令和6年10月11日(金)までに電子メールで通知する。 ただし、質問の回答は本工事の仕様書の追補とみなす。 8.入札(1) 入札書受付期間令和6年10月15日(火)午前9時から令和6年10月16日(水)午後4時まで(要領に規定する書面参加を行う場合は、令和6年10月15日(火)午後5時から令和6年10月16日(水)午前9時までを除く。)(2) 開札日時令和6年10月17日(木)午前9時40分(3) 開札場所北広島町役場2階(電子入札システム) ※開札立会は任意9.電子入札対象案件への書面参加この案件は、要領第3条に規定する場合のほか電子入札システムに対応していない者の書面による参加を可とする。書面で参加する場合は、令和6年10月16日(水)午後3時までに、北広島町財政政策課へ書面参加申請書を提出すること。 の現場に右欄の人数配置できること。 (ア) (1)アの業種について建設業法第15条第2号イ、ロ、ハに該当する者であること。 ※経営業務の管理責任者及び専任技術者を除く。 (イ) アに掲げる種類の工事(規模要件を除く。)において監理技術者又は主任技術者等(現場代理人等として監理技術者又は主任技術者に準じて下請業者を指導する立場であったと認められるときを含む。)の経験を有すること。 10.資格要件確認書類(1) 資格要件確認書類提出依頼書により資格要件確認書類の提出を求められた者は、次により提出すること。 (2) 上記提出書類の様式は、北広島町ホームページ内「事業者向け情報>入札・契約>入札手続き>入札・契約、施工関係 各種様式集>一般競争入札事務処理要綱(事後審査型)関係様式」別記様式第5号~第7号を使用する。 11.その他(1) 入札保証金は免除する。 (2) 最低制限価格制度の対象工事である。 (3) 工事費内訳書は、電子入札システムにより提出すること。 (書面参加の場合は、10月16日(水)午後4時までに北広島町財政政策課へ提出すること。)(4) 内容審査後、落札決定する。 (5) 次に掲げる場合は、その者の入札を無効とする。 ア 入札に参加する者に必要な資格のない者が入札したときイ 入札を取り消すことができる能力を有しない者の意思表示であるときウ 契約担当職員において定めた入札に関する条件に違反したときエ 入札者が2以上の入札をしたときオ 他人の代理を兼ね、又は2人以上を代理して入札をしたときカ 入札者が連合して入札をしたとき、その他入札に際して不正の行為があったときキ 必要な記載事項を確認できない入札をしたとき12.問い合わせ先○入札手続きに関する問い合わせ先北広島町役場 財政政策課 政策契約係 電話:0826-72-7359○工事等に関する問い合わせ先北広島町役場 環境生活課 下水道係 電話:0826-72-7365電子メールアドレス:gesuido@town.kitahiroshima.lg.jpア 提出期間 資格要件確認書類提出依頼書を受け取った日から、同依頼書において指定された提出期限の日(令和6年10月21日(月))までの毎日(休日は除く)午前9時から午後5時までイ 提出書類 (ア) 資格要件確認書類提出書(イ) 企業の施工実績、技術者の資格・工事経験調書(ウ) 建設工事施工実績証明(願)書(※施工実績を求める場合のみ)(エ) 法人税申告書別表2(同族関係者等の判定に関する明細書)の写し(オ) 登記事項証明書の写し(3か月以内のもの)(カ) 経営事項審査の総合評定値通知書の写しウ 提出方法及び提出場所電子入札システムへの登録または持参(持参の場合の提出場所は、北広島町役場財政政策課(北広島町役場本庁2階) 令和6年度 10%令和6年度川小田処理区における機械装置の更新(機能強化)に係る工事対象処理区北広島町1期(川小田地区)対象機器【機械設備】 【電気設備】 【機械設備】・自動荒目スクリーン ・脱臭ファン ・原水ポンプ槽水位計 ・2号中継ポンプ№2・破砕機 ・換気扇 ・6号中継ポンプ№1,2・原水ポンプ・非常用エンジンポンプ・水中攪拌ポンプ・散水ポンプ・ばっ気ブロワ・給気ファン仕様書事 業 名 農業集落排水事業 路 線 名工 事 名 川小田処理区機械装置更新工事 施 工 場 所 川小田地区区 分 設 計 額 設 計 変 更 額 変 更 請 負 額業 務 価 格消 費 税 相 当 額設 計 金 額工事概要川小田地区農業集落排水処理施設特別仕様書北広島町第1章 総 則農業集落排水事業 川小田地区 機能強化対策工事の施工に当たっては,広島県「土木工事等共通仕様書」を主とし,(社)公共建築協会「公共建築工事標準仕様書(建築工事編)」,「公共建築工事標準仕様書(機械設備工事編)」及び「公共建築工事標準仕様書(電気設備工事編)」によるほか,この特別仕様書によるものとする。第2章 工事の内容1.目 的この工事は,農業集落排水事業(機能強化対策)北広島町1期地区の一環として,川小田水質管理センター及びポンプ施設の設備を更新するものである。なお,本工事は施設を供用しながらの更新工事である。2.工事場所北広島町 川小田水質管理センター中継ポンプ 6箇所3.汚水処理施設の計画概要・ 処理対象汚水 生活排水(し尿及び生活雑排水)・ 計画処理対象人口 910人・ 計画汚水量 246m3/日(日平均汚水量)・ 計画水質 項 目 流入水質 処理水質BOD 200mg/ℓ 20mg/ℓS S 200mg/ℓ 50mg/ℓ・ 型式 JARUS-Ⅲ96型・ 処理方式 流量調整、嫌気性ろ床及び接触ばっ気を組合せた方式4.処理工程消 毒 槽流 量 調 整 槽脱離液汚 泥自動微細目スクリーンば っ 気 沈 砂 槽汚 水 計 量 槽嫌 気 性 ろ 床 槽 汚 泥 濃 縮 貯 留 槽汚 泥 貯 留 槽返送水汚 泥汚 泥放 流搬 出原 水 ポ ン プ 槽破 砕 機 細 目 ス ク リ ー ン汚 泥接 触 ば っ 気 槽沈 殿 槽散 水 ポ ン プ 槽散水自動荒目スクリーン自動微細目スクリーンバイパスバイパスオーバーフロー5.工事範囲川小田水質管理センターの内,下記に示すものを工事範囲とする。機械設備工事 一式(機器更新工事,他)電気設備工事 一式(機器更新工事,他)川小田地区中継ポンプの内,下記に示すものを工事範囲とする。機械設備工事 一式(機器更新工事,他)第3章 処理性能の確保1.処理機能の確保・ 受注者は,設計図書に明示されていない処理施設の細部構造の設計,機械設備類の選択並びに配置等については,監督職員の承諾を得て実施するものとする。この場合,受注者は,第2章第3項の汚水処理施設の計画概要及び設計図書を熟知し,所定の処理性能が確保されるよう努めなければならない。・ 受注者は,設計図書に示されている汚水処理施設の構造,機械設備等について,疑義又は改善意見がある場合には,監督職員と協議し処理しなければならない。第4章 工 期本工事の工期には,検査期間としての13日間を見込んでいる。第5章 施工体制台帳受注者は,別紙1(技術者台帳)を追加して施工体制台帳を作成し工事現場に備えるとともに,監督職員に提出するものとする。なお,様式には,監理技術者,主任技術者(下請けを含む)及び専門技術者の顔写真,氏名,所属会社名を記載するものとする。また,共通仕様書様式の工事作業所災害防止協議会兼施工体系図に,下請会社の担当する工種の明記を徹底すること。第6章 現場の管理受注者は,工事現場内において,監理技術者,主任技術者(下請けを含む)に工事名,工期,顔写真,所属会社名及び証明印の入った名札を着用させるものとする。(名札様式)監理(主任)技術者氏 名 ○ ○ ○ ○○ ○ ○ ○ 工 事 ・用紙の大きさは,名刺サイズ以上・印は所属会社の社印工期 自○○年○○月○○日 ・写真のサイズは2㎝×3cm程度とする。至○○年○○月○○日◇ ◇ 建設株式会社印第7章 工事カルテ作成,登録受注者は,受注時または変更時において工事請負代金額が 500 万円以上の工事について,工事実績情報サービス(CORINS)に基づき,受注・変更・完成・訂正時に工事実績情報として「工事カルテ」を作成し,監督職員に確認の上,受注時は契約締結の日から 10 日以内に,登録内容の変更及び訂正時は変更契約締結の日から 10 日以内に登録機関に登録しなければならない。(ただし,工事請負代金額 500 万円以上2,500万円未満の工事については,受注・訂正時のみ登録するものとする。)また,「工事カルテ受領書」が届いた場合,ただちにその写しを監督職員に提出すること。第8章 施工条件1.工程制限該当なし2.部分引渡し該当なし第9章 現場条件1.関連工事該当無し2.第三者に対する措置該当なし3.施設の運転本工事は,施設を供用しながらの更新工事である。よって,施設の浄化槽管理業者および浄化槽清掃業者との連絡を密にし,供用に支障をきたさないように注意しなければならない。第10章 地元説明会受注者は,工事の施工前及び施工中,その必要な都度「地元説明会」等を開催し,住民に工事の内容,施工時期,環境対策等を説明してその協力を得るように努めるものとする。第11章 工事用電力この工事に使用する電力設備及び電力料金は,受注者の負担とする。本工事は,施設を供用しながらの更新工事であるので,施設自体の運転費用,汚泥引抜き費用は市の負担とする。第12章 工事用材料1.機械・電気設備工事(1) 機械・電気設備の製造に用いる材料又は部品は,すべて次の規格・規準に適合したものでなければならない。日本工業規格(JIS),電気規格調査会標準規格(JEC),日本電気工業会標準規格(JEM),給排水空調設備規格,し尿浄化槽構造基準,その他関係法令等(2) 機械・電気設備のうち工場で製作するものについては,製作図面を作成し監督職員の承諾を得て製作するものとする。(3) 原動機,ポンプ,ブロワ等の汎用製品については,製造工場試験成績表及び合格証等を添付して監督職員の承諾を受けなければならない。(4) 機械設備の仕様は,別紙「機械設備の仕様」のとおりである。(5) 電気設備の仕様は,別紙「電気設備の仕様」のとおりである。第13章 施 工1. 機械・電気設備工事(1) 機械設備は,全塗装を行うものとするが,ステンレス及び樹脂製品並びに原動機,ポンプ,ブロワ等の汎用製品についてはこの限りでない。塗装の仕様は,「公共建築工事標準仕様書(機械設備工事編)」によるものとする。 (2) 機械・電気設備の据付配置は,設計図書並びに現場を熟知するとともに疑義を正し,詳細に内容を把握した上で処理施設の性能が十分発揮できるように行わなければならない。(3) バルブ類をねじ込み式で布設する場合には,ニップル・ユニオン等を用いて,バルブ類の脱着可能な布設方法をとることとする。2. 維持管理当該処理施設の完成後の維持管理は,保守点検業者の行う巡回管理及び受益者で組織する管理組合の行う日常点検等を組み合わせた体制により行うものとしている。したがって,受注者は,処理施設がこれら維持管理の実態に対応し,かつ,安全なものとなるよう努めなければならない。第14章 施工管理1.施工管理受注者は,第1章に示す共通仕様書によるとともに,「農業集落排水施設検査・施工管理指標(案)」(農業集落排水事業諸基準等作成全国検討委員会)に準拠し施工管理するものとする。2.工事記録写真撮影(1) 工事の施工順序に従い,監督職員の指示又は必要に応じて記録写真を整備し,工事完了後提出しなければならない。埋設される箇所等後日確認できなくなる箇所については,次の工程に移る段階で監督職員に提出し確認を得るものとする。(2) 撮影に当たっては,位置,構造物の種類,番号等を明示する黒板を立て,スケール等によって寸法等を表示するものとする。(3) 写真はカラー撮影,サービス版を原則とし,写真帳はA4版アルバムとする。第15章 通水試運転等1. 工事の完了に伴い,各装置の試運転を行い,各装置が正常に稼働することを確認しなければならない。2. 配管設備は,通水,通気試験及び水圧,気密試験を行い,誤配管,漏れ等のないことを確認しなければならない。3. 試運転は,あらかじめ監督職員と協議して作成した通水試運転等要領書に基づき実施する。4. 試運転に当たっては,各装置の試運転を行う適切な人員を配置しなければならない。5. 試運転には,監督職員の立会を求めなければならない。第16章 竣工時提出物受注者は,工事の完了に伴い,次の図書を作成し提出しなければならない。(1) 工事の出来形図(竣工図)(2) 処理施設の維持管理に必要な図書(設計諸元及び機械・電気設備等操作方法書)(3) 各機械設備の仕様,購入先調書,カタログ等(4) その他監督職員の指示するもの第17章 官公庁等への手続等受注者は,関係諸官庁,NTT及び電力会社に対する一切の手続きを行なうと共に,常に密接な連絡を保ち電気使用開始にあたって支障のないようにしなければならない。これに要する費用は受注者の負担とする。第18章 条件変更の補足説明この工事の施工に当たり,自然的又は人為的な施工条件が設計図書等と異なる場合,あるいは設計図書に明示されていない施工条件について予期することが出来ない特別な状態が生じた場合の施工条件の変更に該当する主な事項は,次のとおりである。・ 基礎の地質・ 掘削土の土質・ 排水量・ 地下埋設物(埋蔵文化財を含む)の出現・ 土捨場等及び運搬道路第19章 定めなき事項この仕様書に定めない事項又はこの工事の施工に当たり疑義が生じた場合は,必要に応じて監督職員と協議するものとする。施工体制台帳様式(技術者台帳) 別紙1工事技術者台帳 元請会社名 会社名 会社名 会社名 会社名①監理技術者名 ③主任技術者名 ③主任技術者名 ③主任技術者名 ③主任技術者名生年月日 生年月日 生年月日 生年月日 生年月日専任 ・ 非専任 専任 ・ 非専任 専任 ・ 非専任 専任 ・ 非専任【写真添付欄】【写真添付欄】 【写真添付欄】 【写真添付欄】 【写真添付欄】会社名 会社名 会社名 会社名③主任技術者名 ③主任技術者名 ③主任技術者名 ③主任技術者名【注意事項】生年月日 生年月日 生年月日 生年月日専任 ・ 非専任 専任 ・ 非専任 専任 ・ 非専任 専任 ・ 非専任※添付する写真は, 縦 3㎝ 横 2.5㎝【写真添付欄】 【写真添付欄】 【写真添付欄】 【写真添付欄】 程度の大きさとし, 顔が判別できるものとする。 会社名 会社名 会社名 会社名③主任技術者名 ③主任技術者名 ③主任技術者名 ③主任技術者名本様式は,2部作成し,生年月日 生年月日 生年月日 生年月日1部保管し,1部提出する。 専任 ・ 非専任 専任 ・ 非専任 専任 ・ 非専任 専任 ・ 非専任ただし,カラーコピーの場合は,カラーコピーを提出する。 また,デジカメ使用の場合は,印刷したもので可とする。 【写真添付欄】 【写真添付欄】 【写真添付欄】 【写真添付欄】北広島町川小田地区処理施設機械設備の仕様第1項 自動荒目スクリーン(更新)1.使用目的本装置は,流入汚水中の大きな夾雑物を除去し,後段の各種設備の機能低下を防止するために 本装置は,流入汚水中の大きな夾雑物を除去し,後段の各種設備の機能低下を防止するために設置するものである。 2.仕 様1) : 自動掻上げ式2) : 1 基3) : 水路幅 ,機長 程度4) : 50 ㎜5) : m3/時(時間最大汚水量)6) : 屋外冠水型減速機付き誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz)3.主要部材質1)フレーム : SUS3042) スクレーパー : SUS3043) スクリーン : SUS3044) ホイール・ベルト : 樹脂製(ポリウレタン他)5) : ステンレス鋼・機械構造用炭素鋼4.付属品1)案内板 : SUS304 1 式2) 取付金具 : SUS304 1 式3) し渣かご : SUS304 2 個4) シーリングゴム5.試験・検査製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 6.特記事項次の設備との取り合いに注意すること。 1) 自動荒目スクリーンカバー2) し渣かご・し渣かご受台7.参考1)既設設置メーカー : 新明和工業(株)2) 型番 : VS-2Hスプロケット・チェン型 式数 量形状寸法 500㎜ 1,500㎜目 幅処理能力 29.6電 動 機0.025第2項 破 砕 機(更新)1.使用目的 本装置は,流入汚水中の夾雑物を破断破砕することにより,後段のポンプ等の閉塞を防止し,自動微細目スクリーンで除去されるスクリーンし渣を取り扱い易くし,且つ,後段の生物処理の安定化を図るために設置するものである。 2.仕 様1) : 回転ドラム式(コントロール式)2) : 1 台3) : m3/時(時間最大汚水量)4) : 屋外冠水竪形誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz)3.主要部材質1) ケーシング : FC2502) シャフト・ドラム : SCM415・SUS3033) 固定歯・カッターバー: SKD4) 切削歯 : SCS・K104.付属品1) 流入側短管 : FC200 1 式2) 基礎ボルト : SUS304 1 式3) その他必要なもの : 菊型フランジ5.その他1) 塗 装 : 防食塗装(メーカー標準)2) 既設機器撤去 : 流入側配管撤去6.試験・検査製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.参考1) 既設設置メーカー : 新明和工業(株)2) 型番 : SC150型(コントロール式)8.特記事項既設装置のメーカーは本装置の販売を中止しており、更新に当たっては、下記のメーカーの製品同等品を想定している。 機器メーカー : コミニューターサービス(株) 機器型式 : 7R 冠水型(コントロール式)電動機0.20型 式数 量処 理 能 力 29.6第3項 原水ポンプ(更新)1.使用目的 本装置は,流入汚水を後段の流量調整槽へ揚水するために設置するものである。 2.仕 様1) : 水中渦流式汚水汚物ポンプ(ボルテックス)2) : 2 台3) : φ 80 ㎜4) : m3/分5) : m6) : 乾式水中型誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz 4極 直入れ始動)3.主要部材質1) ケーシング・羽根車: FC2002) シャフト : SUS420J2又はSUS4034.付属品1) 着脱装置 : FC200 1 式(既設流用)2) 基礎ボルト : SUS304 1 式(既設流用)3) ガイドパイプ : SUS304 1 式(既設流用)4) ガイドホルダー : SUS304 1 式(既設流用)5) 吊上用チェーン : SUS304 1 式(既設流用)6) フック : SUS304 2 式(既設流用)7) 水中ケーブル5.塗 装1) 塗 装 : 防食塗装(メーカー標準)6.試験・検査 JIS-B-8301に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.特記事項1) 軸封部は,ダブルメカニカルシールを使用し,中間には軸封油を密閉した構造とする。 2) 回転部重量及び水力スラストは,電動機の軸受で支持することを原則とする。 8.参考1) 既設設置メーカー : 新明和工業(株)2) 型番 : CV80-P80BS電動機2.20型 式数 量口 径揚水量 0.5全揚程 7.5第4項 非常用エンジンポンプ(更新)1.使用目的 本装置は,停電時に原水ポンプ槽に流入した汚水を後段の流量調整槽に移送するために設置するものである。また,異常流入があった場合,原水ポンプの補助として用いる。 2.仕 様1) : 横軸無閉塞自給式汚水汚物ポンプ2) : 1台3.ポンプの仕様1) : φ 80㎜2) : m3/分3) : m4.エンジンの仕様1) : 空冷4サイクルガソリンエンジン2) : メーカー標準3) : メーカー標準4) : 自動車用無鉛ガソリン5.自動起動盤の仕様1) : 屋内壁掛型2) : 自動起動6.主要部材質1) ポンプケーシング : FC200又はADC,AC2) 羽根車 : FC200又はFCD450以上3) エンジン本体 : FC200又はAC7.付属品1) ストレーナ : 1 式2) 基礎ボルト : SUS304 1 式3) エンジン起動盤 : 1 式4) バッテリー : 1 式5) 排気用可撓管 : 1 式8.塗 装1) 塗 装 : 防食塗装(メーカー標準)9.試験・検査 JIS-B-8301に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 型 式数 量口 径揚 水 量 0.5全 揚 程 7.5型 式定 格 出 力バ ッ テ リ ー使 用 燃 料型 式起 動 方 式10.参考1) 既設設置メーカー : 新明和工業(株)2) 型番 : ASE80SK第5項 水中撹拌ポンプ(更新)1.使用目的 本装置は、流量調整槽に設置し,水槽内の汚水を撹拌し,水質を均一化するとともに沈殿を防止し,且つ腐敗や臭気の発生を防止するために設置するものである。 2.仕 様1) : 水中渦流ポンプ,ディフューザー付2) : 2 台3) : φ 80 ㎜4) : m3/台 (幅3.40m×長4.80m×深3.50m×2室)5) : 乾式水中型誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz 4極 直入れ始動)3.主要部材質1) ケーシング : FC200又は同等品以上2) シャフト : SUS420製J2又は同等品以上3) インペラ : FC200又は同等品以上4) ディフューザー : FC200又は同等品以上(既設流用)4.付属品1) 着脱装置 : FC200 1 式(既設流用)2) 基礎ボルト : SUS304 1 式(既設流用)3) ガイドパイプ : SUS304 1 式(既設流用)4) ガイドホルダー : SUS304 1 式(既設流用)5) 吊上用チェーン : SUS304 1 式(既設流用)6) フック : SUS304 1 式(既設流用)7) 水中ケーブル8) 調整弁・消音器 : メーカー標準 (既設流用)5.塗 装1) 塗 装 : メーカー標準仕様6.試験・検査 JIS-B-8301に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.特記事項1) 軸封部にはメカニカルシールを使用し,原水が電動機内に浸入しないよう中間に軸封油を密封した構造とする。 2) 回転部重量及び水力スラストは,電動機の軸受で支持することを原則とする。 8.参考1) 既設設置メーカー : 新明和工業㈱2) 型番 : JA22V2.20型 式数 量口 径攪拌量 58.0電動機第6項 散水ポンプ(更新)1.使用目的 本装置は,処理工程における消泡及びスカムの破砕を目的とした散水ノズルへ処理水を揚水するために設置するものである。 2.仕 様1) : 水中汚水ポンプ2) : 1 台3) : φ 50 ㎜4) : m3/分5) : m6) : 乾式水中型誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz 2極 直入れ始動)3.主要部材質1) ケーシング・羽根車: FC200又は特殊ナイロン樹脂2) シャフト : SUS420J2又はSUS403又はSUS3044.付属品1) 着脱装置 : FC200 1 式 (既設流用)2) 基礎ボルト : SUS304 1 式 (既設流用)3) ガイドパイプ : SUS304 1 式 (既設流用)4) ガイドホルダー : SUS304 1 式 (既設流用)5) 吊上用チェーン : SUS304 1 式 (既設流用)6) フック : SUS304 1 式 (既設流用)7) 水中ケーブル5.塗 装1) 塗 装 : 防食塗装(メーカー標準)6.試験・検査 JIS-B-8301に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.特記事項1) 軸封部は,ダブルメカニカルシールを使用し,中間には軸封油を密閉した構造とする。 2) 回転部重量及び水力スラストは,電動機の軸受で支持することを原則とする。 8.参考1) 既設設置メーカー : 新明和工業(株)2) 型番 : AH501-P50S電動機0.75型 式数 量口 径揚水量 0.07全揚程 13.0第7項 ばっ気ブロワ(更新)1.使用目的 本装置は,生物処理に必要なエアレーション用空気を送気する他に,エアリフトポンプに必要な空気や,ばっ気沈砂槽及び汚泥貯留槽の撹拌に必要な空気を送気するために設置するものである。 2.仕 様1) : 容積型ブロワ(ルーツ)2) : 3 台3) : φ ㎜4) : m3/分5) : kPa ( mAq)6) : 全閉外扇型誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz)3.主要部材質1) ケーシング : FC2002) ハウジング : FC2003) ローター : FCD5004) シャフト : S45C,FCD500,SCM4354.付属品1) ベース(防振台付) : 1 式2) 消音器(吸込・吐出) : 1 式3) プーリー・ベルト・ベルトカバー : 1 式4) 安全弁 : 1 個5) 逆止弁 : 1 個6) 圧力計 : 1 個7) 伸縮継手 : 1 個8) 防振ゴム : 1 式9) 基礎ボルト : 1 式5.塗 装1) 塗 装 : 耐熱塗装(メーカー標準)6.試験・検査製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.参考1) 既設設置メーカー : 新明和工業(株)2) 型番 : ARH65S型 式数 量口 径 65風 量 1.70吐 出 圧 力 54.0 5.50電動機3.7第8項 給気ファン(更新)1.使用目的 本装置は、前処理室の作業環境を保ち、衛生的に維持管理を行うために設置するものである。 2.仕 様1) : ラインファン2) : 前処理室給気3) : 1 台4) : mm5) : m3/時6) : Pa7) :8) : 防滴保護型電動機9) : kW10) : 1φ100V 60Hz3.主要部材質1) ケーシング : 冷間圧延鋼板 SPCC2) 羽根車 : 冷間圧延鋼板 SPCC4.付属品1) 取付材料 : 1 式2) 防振継手 : 1 式(2個/台)5.塗 装1) 塗 装 : メーカー標準6.試験・検査 JIS-B-8330に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.参考1) 既設設置メーカー : (株)荏原製作所2) 型番 : 3LFM26.3S電 源取 付 姿 勢 水平取付電動機参考出力 0.30風 量 1,930静 圧 150型 式用 途数 量接続口径 300第9項 脱臭ファン(更新)1.使用目的 本装置は,臭気発生箇所より適切に臭気を捕集し,土壌脱臭装置に送気または屋外に放出するために設置するものである。 2.仕 様1) : モートル別置きベルト駆動式ターボファン2) : 1 台3) : φ4) : m3/分5) : Pa6) : 防滴保護型電動機 絶縁E種以上kW以下(3φ200V 60Hz 4極 直入れ始動)3.主要部材質1) ケーシング・羽根車: 耐食性樹脂2) 羽根車 : 耐食性樹脂4.付属品1) Vプーリー : 1 式2) Vベルト : 1 式3) ベルトカバー : 1 式4) 防振架台 : 1 式5) 防振継手 : 軟質塩化ビニル又は合成樹脂製 2 個6) 相フランジ : 2 個7) 基礎ボルト : SUS304 1 式5.塗 装1) 塗 装 : 耐食塗装(メーカー標準)6.試験・検査 JIS-B-8330に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.参考1) 既設設置メーカー : セイコー化工機株式会社2) 型番 : FTF152-RH1-B10.0風 圧 1,180電動機0.75型 式数 量接続管口径 200㎜風 量第10項 換 気 扇(更新)1.使用目的 本装置は,作業環境を良好に保ち,衛生的に維持管理を行えるよう各室の換気を行うために設置するものである。 2.仕 様1) : 有圧換気扇2) : スクリーン室3) :4) : 台5) : ㎜6) : m3/時7) : Pa8) : W9) : 1φ100V 60Hz10) : EWF-35CSA23.主要部材質1) フレーム : 冷間圧延鋼板 SPCC2) 羽根車 : 冷間圧延鋼板 SPCC4.付属品1) 取付ネジ : SUS304 1 式2) 保護ガード : 本体の材質に準ずる 1 式3) 取付枠 : 木枠製又はSUS304 1 式(必要な場合)5.塗 装1) 塗 装 : メーカー標準6.試験・検査 JIS-B-8330に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 風 量静 圧参 考 出 力電 源参考品番(三菱)100502,0003501型 式使 用 場 所数 量口 径用 途 排気川小田地区処理施設電気設備の仕様北広島町第1章 一般事項1-1.適 用・ 本仕様は, 農業集落排水事業 川小田地区 機能強化対策工事の電気設備工事に適用する。・ 本工事は,本仕様,関係仕様書並びに設計図書に基づき承諾図で決定ののち製作するものとする。1-2.工事場所北広島町川小田地内 川小田水質管理センター1-3.適用規格機器の設計,製作にあたっては,本仕様に記載した事項のほか下記の規格関係法令に従うものとする。・ 日本工業規格(JIS)・ 電気学会電気規格調査会標準規格(JEC)・ 日本電気工業会標準規格(JEM)・ 日本電線工業会標準規格(JCS)・ 電気設備技術基準(通産省令)・ 建築基準法・ 消防法・ 国交省営繕部「公共建築工事標準仕様書(電気設備工事編)」・ 日本下水道事業団 設計基準(案)・ その他関係法令,条例および規格1-4.工事概要本工事は,川小田水質管理センターの汚水処理設備を運転操作するための電気設備の一部を更新するものである。1-5.工事範囲下記の機器の製作,据付および運転調整を行うものとする。・ 計装設備(投込圧力式水位計の更新)・ その他必要な諸工事第2章 機器仕様2-1.計装設備1.概 要本設備は,施設の監視,操作に必要な水位,流量,水質を計測するため設置する。なお,屋外に設ける計装の信号ライン及び電源ラインには,アレスタを設置し避雷対策を施すものとする。2.設備構成① 投込圧力式水位計 1式3.詳細仕様① 投込圧力式水位計1)用 途 原水ポンプ槽の水位測定2)精 度 ±2%FS以内(組合せ精度)3)材 質 エレメント SUS304・316・316L接 液 部 SUS304・3164)仕 様 測定範囲 0~3m接点出力 5点以上5)水位出力 DC 4~20mA 又は 1~5V6)電 源 AC 100V7)付 属 品 吊下げ機器,専用ケーブル,表示器,変換器,その他必要なもの8)既設設置品 愛知時計電機㈱ AMLP第3章 据付並びに配線工事3-1.一般事項本工事の据付配線工事ならびにその工程などは,あらかじめ監督職員と打合せ,その指示により行わなければならない。3-2.据付け工事・ 各章の機器設備を図面どおり所定の位置に堅牢に据付けするものとする。・ 据付けは,各機器製作会社の熟練した技術者の指導に基づき据付け工事をする。・ コンクリート施工のうち,コンクリート配合,型枠,養生等については係員の承諾および指示に従うこと。3-3.電気配線工事・ 各種配線は電線管内またはケーブルラックに敷設する。・ 各機器類,鋼製電線管,ボックスその他必要な箇所には接地工事を行わなければならない。北広島町川小田地区ポンプ施設機 械 設 備 の 仕 様第2項 2号中継ポンプ(更新)1.使用目的 本装置は,2号中継ポンプ場に流入した汚水を後段の中継ポンプ場へ揚水するために設置するものである。 2.仕 様1) : 水中渦流式汚水汚物ポンプ(ボルテックス)2) : 1 台 (NO.2を更新)3) : φ 65 ㎜4) : m3/分5) : m6) : 乾式水中型誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz 4極 直入れ始動)7) : オートカット又はサーマルプロテクタ3.主要部材質1) ケーシング・羽根車: FC2002) シャフト : SUS420J2又はSUS4034.付属品1) 着脱装置 : FC200 1 式/台(既設流用)2) 基礎ボルト : SUS304 1 式/台(既設流用)3) ガイドパイプ : SUS304 1 式/台(既設流用)4) ガイドホルダー : SUS304 1 式/台(既設流用)5) 吊上用チェーン : SUS304 1 式/台(既設流用)6) フック : SUS304 1 式/台(既設流用)7) 吸込ノズル : SUS304 1 式/台8) 逆止弁 : SUS304 1 式/台(既設流用)9) ボール弁 : SUS304 1 式/台(既設流用)10) 水中ケーブル : 1 式/台11) 流入バッフル : SUS304 1 式/槽(既設流用)12) 槽内配管 : SUS304 1 式/槽(既設流用)5.塗 装1) 塗 装 : 防食塗装(メーカー標準)6.試験・検査 JIS-B-8301に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.特記事項1) 軸封部は,ダブルメカニカルシールを使用し,中間には軸封油を密閉した構造とする。 2) 回転部重量及び水力スラストは,電動機の軸受で支持することを原則とする。 8.参考1) 既設設置メーカー・型番 新明和工業(株) CVL501-P65B電動機0.75保護装置型 式数 量口 径揚水量 0.185全揚程 2.1第6項 6号中継ポンプ(更新)1.使用目的 本装置は,6号中継ポンプ場に流入した汚水を後段の中継ポンプ場へ揚水するために設置するものである。 2.仕 様1) : 水中渦流式汚水汚物ポンプ(ボルテックス)2) : 2 台3) : φ 65 ㎜4) : m3/分5) : m6) : 乾式水中型誘導電動機 絶縁E種以上kW以下(3φ200V 60Hz 4極 直入れ始動)7) : オートカット又はサーマルプロテクタ3.主要部材質1) ケーシング・羽根車: FC2002) シャフト : SUS420J2又はSUS4034.付属品1) 着脱装置 : FC200 1 式/台(既設流用)2) 基礎ボルト : SUS304 1 式/台(既設流用)3) ガイドパイプ : SUS304 1 式/台(既設流用)4) ガイドホルダー : SUS304 1 式/台(既設流用)5) 吊上用チェーン : SUS304 1 式/台(既設流用)6) フック : SUS304 1 式/台(既設流用)7) 吸込ノズル : SUS304 1 式/台8) 逆止弁 : SUS304 1 式/台(既設流用)9) ボール弁 : SUS304 1 式/台(既設流用)10) 水中ケーブル : 1 式/台11) 流入バッフル : SUS304 1 式/槽(既設流用)12) 槽内配管 : SUS304 1 式/槽(既設流用)5.塗 装1) 塗 装 : 防食塗装(メーカー標準)6.試験・検査 JIS-B-8301に準拠した,製造メーカー仕様の試験・検査を行い,検査成績書及びミルシートを提出する。 7.特記事項1) 軸封部は,ダブルメカニカルシールを使用し,中間には軸封油を密閉した構造とする。 2) 回転部重量及び水力スラストは,電動機の軸受で支持することを原則とする。 8.参考1) 既設設置メーカー・型番 新明和工業(株) CVL651-P65G電動機1.50保護装置型 式数 量口 径揚水量 0.487全揚程 3.4¥ 円也明細書番 号機械設備工事処理施設(川小田地区) 式 1.0 M-1電気設備工事処理施設(川小田地区) 式 1.0 E-1機械設備工事ポンプ施設(川小田地区) 式 1.0 MP-1小 計消費税相当額 % 10請負工事費計規 格 ・ 寸 法 単 位 数 量 単 価 金 額 備考 第 1 号 請負工事費明細書名 称¥ 円也明細書番 号機械設備工事処理施設(川小田地区) 式 1.0計数 量 規 格 ・ 寸 法 備考 第 M-1 号単 価 金 額 名 称請負工事費明細書単 位¥ 円也明細書番 号電気設備工事処理施設(川小田地区) 式 1.0計 第 E-1 号 請負工事費明細書名 称 規 格 ・ 寸 法 単 位 数 量 単 価 金 額 備考¥ 円也明細書番 号機械設備工事ポンプ施設(川小田地区) 式 1.0計 第 MP-1 号名 称 規 格 ・ 寸 法 単 位 数 量 単 価 金 額請負工事費明細書備考図面番号工事名図面名尺 度工事場所施工年度事業主体 北広島町山県郡北広島町1 NON令和6年度 フローシート農業集落排水事業川小田地区 機能強化対策工事管理室動力制御盤 計装盤施工範囲機械設備①自動荒目スクリーン(更新)②破砕機(更新)③No.1原水ポンプ(更新)④No.2原水ポンプ(更新)⑤非常用エンジンポンプ(更新)⑥No.1水中撹拌ポンプ(更新)⑦No.2水中撹拌ポンプ(更新)⑧散水ポンプ(更新)⑨No.1ばっ気ブロワ(更新)⑩No.2ばっ気ブロワ(更新)⑪No.3ばっ気ブロワ(更新)⑫給気ファン(更新)⑬脱臭ファン(更新)⑭スクリーン室排気ファン(更新)電気設備⑱原水ポンプ槽水位計(更新)⑧散水ポンプ(更新)⑦No.2水中撹拌ポンプ(更新)⑥No.1水中撹拌ポンプ(更新) ③④原水ポンプ(更新)No.1・2⑱原水ポンプ槽水位計(更新)②破砕機(更新)①自動荒目スクリーン(更新)⑤非常用エンジンポンプ(更新)⑬脱臭ファン(更新)⑭スクリーン室排気ファン(更新)⑫給気ファン(更新)⑨No.1ばっ気ブロワ(更新)⑩No.2ばっ気ブロワ(更新)⑪No.3ばっ気ブロワ(更新)⑮積算記録計(別途)⑯負荷量演算器(別途)⑲UV計(別途)図面番号工事名図面名尺 度工事場所施工年度工事場所1:50 2北広島町山県郡北広島町令和6年度農業集落排水事業川小田地区 機能強化対策工事下部平面図施工範囲機械設備①自動荒目スクリーン(更新)②破砕機(更新)③No.1原水ポンプ(更新)④No.2原水ポンプ(更新)⑤非常用エンジンポンプ(更新)⑥No.1水中撹拌ポンプ(更新)⑦No.2水中撹拌ポンプ(更新)⑧散水ポンプ(更新)⑨No.1ばっ気ブロワ(更新)⑩No.2ばっ気ブロワ(更新)⑪No.3ばっ気ブロワ(更新)⑫給気ファン(更新)⑬脱臭ファン(更新)⑭スクリーン室排気ファン(更新)電気設備⑱原水ポンプ槽水位計(更新)②破砕機(更新)⑤非常用エンジンポンプ(更新)⑧散水ポンプ(更新)③No.1原水ポンプ(更新)④No.2原水ポンプ(更新)⑦No.2水中撹拌ポンプ(更新)⑥No.1水中撹拌ポンプ(更新)⑱原水ポンプ槽水位計(更新)⑲UV計(別途)図面番号工事名図面名尺 度工事場所施工年度事業主体 北広島町山県郡北広島町3 1:50上部平面図令和6年度農業集落排水事業川小田地区 機能強化対策工事施工範囲機械設備①自動荒目スクリーン(更新)②破砕機(更新)③No.1原水ポンプ(更新)④No.2原水ポンプ(更新)⑤非常用エンジンポンプ(更新)⑥No.1水中撹拌ポンプ(更新)⑦No.2水中撹拌ポンプ(更新)⑧散水ポンプ(更新)⑨No.1ばっ気ブロワ(更新)⑩No.2ばっ気ブロワ(更新)⑪No.3ばっ気ブロワ(更新)⑫給気ファン(更新)⑬脱臭ファン(更新)⑭スクリーン室排気ファン(更新)電気設備⑱原水ポンプ槽水位計(更新)⑬脱臭ファン(更新)⑫給気ファンファン(更新)(更新)⑭スクリーン室排気ファン⑩No.2ばっ気ブロワ(更新)⑨No.1ばっ気ブロワ(更新)⑪No.3ばっ気ブロワ(更新)⑲UV計(別途)⑰可搬式ポンプコンセント盤(別途)⑯負荷量演算器(別途)⑮積算記録計(別途)図面番号工事名図面名尺 度工事場所施工年度事業主体4北広島町山県郡北広島町1:50設備C-C断面図令和6年度農業集落排水事業川小田地区 機能強化対策工事施工範囲機械設備①自動荒目スクリーン(更新)②破砕機(更新)③No.1原水ポンプ(更新)④No.2原水ポンプ(更新)⑤非常用エンジンポンプ(更新)⑥No.1水中撹拌ポンプ(更新)⑦No.2水中撹拌ポンプ(更新)⑧散水ポンプ(更新)⑨No.1ばっ気ブロワ(更新)⑩No.2ばっ気ブロワ(更新)⑪No.3ばっ気ブロワ(更新)⑫給気ファン(更新)⑬脱臭ファン(更新)⑭スクリーン室排気ファン(更新)電気設備⑱原水ポンプ槽水位計(更新)⑨No.1ばっ気ブロワ(更新)(更新)⑦No.2水中撹拌ポンプ②破砕機(更新)⑧散水ポンプ(更新)⑱原水ポンプ槽水位計(更新) ③No.1原水ポンプ④No.2原水ポンプ⑮積算記録計(別途)⑯負荷量演算器(別途)⑲UV計(別途)図面番号工事名図面名尺 度工事場所施工年度工事場所 北広島町山県郡北広島町令和6年度農業集落排水事業川小田地区 機能強化対策工事5 NON破砕機更新計画図施工範囲破砕機(既設機器) 破砕機(更新機器)既設破砕機(新明和工業㈱SC150M) 更新破砕機(コミニューターサービス㈱7R冠水型(コントロール式))機械設備①自動荒目スクリーン(更新)②破砕機(更新)③No.1原水ポンプ(更新)④No.2原水ポンプ(更新)⑤非常用エンジンポンプ(更新)⑥No.1水中撹拌ポンプ(更新)⑦No.2水中撹拌ポンプ(更新)⑧散水ポンプ(更新)⑨No.1ばっ気ブロワ(更新)⑩No.2ばっ気ブロワ(更新)⑪No.3ばっ気ブロワ(更新)⑫給気ファン(更新)⑬脱臭ファン(更新)⑭スクリーン室排気ファン(更新)電気設備⑱原水ポンプ槽水位計(更新)135 240既設流入管切断既設破砕機撤去既設破砕機撤去既設流出管流用既設流入管流用破砕機更新破砕機更新既設流出管塗装替3種ケレンの上、エポキシ樹脂塗装既設流入管塗装替3種ケレンの上、エポキシ樹脂塗装既設流出管塗装替3種ケレンの上、エポキシ樹脂塗装3種ケレンの上、エポキシ樹脂塗装既設流入管塗装替※この図面は拡大しています。(原図サイズA4)図面番号工事名図面名尺 度工事場所施工年度事業主体 北広島町山県郡北広島町1:20000位置図農業集落排水事業川小田地区 機能強化対策工事令和6年度7S=1;20,0000 500北広島町 川小田地区 位置図処川小田水質管理センター1号中継ポンプ処6号中継ポンプ5号中継ポンプ4号中継ポンプ3号中継ポンプ2号中継ポンプ(別途)(更新)(別途)(別途)(別途)(更新)PPPPPP処 理 施 設ポンプ施設凡 例P処図面番号図面名尺 度工事場所工事名施工年度事業主体 北広島町※この図面は縮小しています。 (原図サイズ A1)山県郡北広島町農業集落排水事業川小田地区 機能強化対策工事令和6年度1:202号ポンプ詳細図9施工範囲配置図S=NONMH番号 型 式 数 量 口 径(㎜) 揚水量(m3/min) 揚 程(m) 出力(kW)ボルテックス 65 0.185 2.1 0.75 2号 1型 番 備 考 専用ケーブル延長(m)25設置メーカー新明和工業 CVL501 NO.2を更新2号中継ポンプ(更新)引込開閉器盤制御盤2号中継ポンプ場No.2No.22号中継ポンプ(更新)No.22号中継ポンプ(更新) 【ポンプ施設】②2号中継ポンプNo.2 :本体更新⑥6号中継ポンプNo.1・2:本体更新図面番号図面名尺 度工事場所工事名施工年度事業主体 北広島町※この図面は縮小しています。(原図サイズ A1)山県郡北広島町農業集落排水事業川小田地区 機能強化対策工事令和6年度1:206号ポンプ詳細図13施工範囲配置図S=NONMH番号 型 式 数 量 口 径(㎜) 揚水量(m3/min) 揚 程(m) 出力(kW)ボルテックス 65 0.487 3.4 1.5 6号 2型 番 備 考 設置メーカー新明和工業 CVL651専用ケーブル延長(m)106号中継ポンプ場制御盤引込開閉器盤No.1・26号中継ポンプ(更新)No.1・26号中継ポンプ(更新)No.1・26号中継ポンプ(更新)【ポンプ施設】②2号中継ポンプNo.2 :本体更新⑥6号中継ポンプNo.1・2:本体更新 Agricultural village drainage project Kawaoda treatment area machinery renewal work Agricultural village drainage project Kawaoda treatment area machinery renewal work Kitahiroshima Town Announcement No. 57 We will be holding a post-review type open competitive bidding as follows, and we hereby announce this in accordance with Article 86 of the Kitahiroshima Town Financial Regulations. This matter will be bid through the Hiroshima Prefecture Electronic Bidding System (hereinafter... Kitahiroshima Town, Hiroshima Prefecture Bidding information is as follows. Subject Agricultural village drainage project Kawaoda treatment area machinery renewal work Type Construction Date of announcement or update October 2, 2024 Organization Kitahiroshima Town, Hiroshima Prefecture Date of acquisition October 2, 2024 19:17:29 Specifications Announcement Contents Kitahiroshima Town Announcement No. 57 We will be holding a public competitive bidding with post-review as follows, and this is announced in accordance with Article 86 of the Kitahiroshima Town Financial Regulations. This is an electronic bidding item for which bidding will be conducted using the Hiroshima Prefecture Electronic Bidding System (hereinafter referred to as the "Electronic Bidding System"), and bidding procedures must be carried out in accordance with the Kitahiroshima Town Electronic Bidding Implementation Guidelines (hereinafter referred to as the "Guidelines"). October 2, 2024 Kitahiroshima Town Mayor Mino Hiroshi 1. Name of Project Agricultural Village Drainage Project Kawaoda Treatment Area Machinery Equipment Renewal Work 2. Construction Location Kawaoda, Kitahiroshima Town 3. Construction Period From the day after the contract is concluded to March 31, 2025 4. Estimated Price 24,091,000 yen (excluding consumption tax and local consumption tax equivalent) 5. Construction overview Construction related to the renewal (enhancement of functionality) of machinery and equipment in the Kawaoda treatment area [Machinery and equipment] ?Automatic coarse screen ?Deodorizing fan ?Crusher ?Ventilation fan ?Raw water pump ?Emergency engine pump ?Submersible mixing pump ?Sprinkler pump ?Aeration blower ?Air supply fan [Electrical equipment] ?Raw water pump tank water level gauge [Machinery and equipment] ?No. 2 relay pump No. 2 ?No. 6 relay pump No. 1, 26. Qualifications required for those participating in the bid for this construction (1) Requirements other than technical requirements Meet all of the following requirements. Note that requirements B and C apply to the industry of A unless otherwise specified. A Industry that must be certified as eligible to participate in the bid for Kitahiroshima Town in fiscal years 2023 and 2024 Machinery and equipment installation work B Certified bidder qualification Comprehensive evaluation value of the management review of the business matters attached when applying for the qualification review of A or the comprehensive evaluation value notice of the business matters review with a later review date. Not required (2) Technical requirements: Meet all of the requirements below and be able to submit the relevant documents. C Based on the Notice of Comprehensive Assessment of Business Review attached when applying for the qualification review for the average annual completed construction value A or the Notice of Comprehensive Assessment of Business Review with a later review reference date. More than the estimated price listed in 4 D Whether or not a license under Article 15 of the Construction Business Law (specific construction business license) is required Not required E Location of business office under Article 3, paragraph 1 of the Construction Business Law The main business office or business office must be located within Hiroshima Prefecture. F Not to have been excluded from the nomination list by Kitahiroshima Town on any day between the date of this announcement and the date of opening of bids. Required G Not to be a person other than the contractor for design work etc. related to this construction listed in the right column, and not to have the following relationship with the contractor in terms of capital and personnel. (A) Hold a majority of the total issued shares of the contractor. (B) The director with the representative authority also serves as the director with the representative authority of the contractor. H The applicant has not received a business suspension order under Article 28, Paragraphs 3 or 5 of the Construction Business Law on any day between the date of this announcement and the date of opening of bids. Required I In the case of an applicant for which a petition for the commencement of reorganization proceedings has been filed under the Corporate Reorganization Law and an applicant for the commencement of rehabilitation proceedings under the Civil Rehabilitation Law, after the decision to commence the proceedings has been made, the applicant has been re-certified as eligible to participate in the bid in accordance with the procedures separately stipulated by the Mayor of Kitahiroshima. Required K The applicant does not fall under Article 167-4 of the Enforcement Order of the Local Autonomy Law. Required A Construction track record as a prime contractor for similar type and scale works The applicant has construction track record as a prime contractor or representative of a joint venture for works of the above type and of a scale equal to or larger than this work that have undergone completion inspection between April 1, 2009 and October 1, 2024 (the day before the announcement date). *The applicant's track record as a member of a specified joint venture or ordinary joint venture is limited to those with an investment ratio of 20% or more. Not required B Requirements for assigned engineers A full-time supervising engineer who meets all of the following requirements must be appointed for this work Not required 7. (1) Viewing period: The design documents can be viewed electronically on the Kitahiroshima Town website from October 2, 2024 to October 11, 2024. Location: "Information for businesses > Bidding information > Bidding and public invitation information > Bidding information (public competitive bidding)". If electronic viewing is not possible, paper copies can be viewed at the Kitahiroshima Town Environment and Lifestyle Division from 9:00 a.m. on Wednesday, October 2, 2024 to 5:00 p.m. on Friday, October 11, 2024 (excluding holidays and from 5:00 p.m. to 9:00 a.m.). (2) Deadline for submitting questions: Submit by email to the Kitahiroshima Town Environment and Lifestyle Division by 5:00 p.m. on Tuesday, October 8, 2024. (3) Period for sending responses: The Kitahiroshima Town Environment and Lifestyle Division will notify you by email by Friday, October 11, 2024. However, responses to questions will be considered as addendums to the specifications for this work. 8. Bidding (1) Period for accepting bid documents: From 9:00 AM, Tuesday, October 15, 2024 to 4:00 PM, Wednesday, October 16, 2024 (Excluding the period from 5:00 PM, Tuesday, October 15, 2024 to 9:00 AM, Wednesday, October 16, 2024, if written participation is made as provided for in the Guidelines.) (2) Date and time of bid opening: 9:40 AM, Thursday, October 17, 2024 (3) Location of bid opening: 2nd floor of Kitahiroshima Town Hall (Electronic Bidding System) * Attendance at the bid opening is optional 9. Written participation in projects subject to electronic bidding In addition to the cases provided for in Article 3 of the Guidelines, written participation by those who do not support the electronic bidding system is permitted for this project. If participating in writing, submit a written participation application to the Kitahiroshima Town Financial Policy Division by 3:00 PM, Wednesday, October 16, 2024. The number of people listed in the right column can be deployed at the site. (A) (1) The person must fall under Article 15, item 2, sub-items (a), (b), and (c) of the Construction Business Law for the type of business (a). *Excluding business managers and full-time engineers. (B) The person must have experience as a supervising engineer or chief engineer, etc. (including when it is recognized that the person was in a position to instruct subcontractors as a supervising engineer or chief engineer as a site representative, etc.) in the type of construction work (excluding the size requirement) listed in (a). 10. Qualification Requirements Confirmation Documents (1) Those who are requested to submit the qualification requirements confirmation documents by the qualification requirements confirmation document submission request form must submit them as follows. (2) The format of the above submitted documents is attached to Forms 5 to 7 of "Information for Businesses > Bidding and Contracts > Bidding Procedures > Bidding, Contracts, and Construction-related Various Forms Collection > Forms Related to General Competitive Bidding Administrative Procedures (Post-Review Type)" on the Kitahiroshima Town website. 11. Other (1) Bid security will be waived. (2) The construction work is subject to the minimum price limit system. (3) A breakdown of construction costs must be submitted via the electronic bidding system. (Written submissions must be submitted to the Kitahiroshima Town Finance and Policy Division by 4:00 p.m. on Wednesday, October 16th.) (4) The successful bidder will be determined after reviewing the contents. (5) In the following cases, the bid of the bidder will be invalid. a. When a bidder does not have the necessary qualifications to participate in a bid submits a bid. b. When a person expresses their intention to bid without the ability to cancel their bid. c. When a bidder violates the conditions for bidding established by the contracting officer. d. When a bidder submits two or more bids. e. When a bidder bids concurrently as an agent for another person or on behalf of two or more people. f. When a bidder submits a joint bid, or when other irregularities have occurred in the bidding process. g. When a bid is submitted without the necessary information being confirmed. 12. Contact Information ? For inquiries regarding bidding procedures: Kitahiroshima Town Office, Finance and Policy Division, Policy Contract Section, Telephone: 0826-72-7359 ? For inquiries regarding construction, etc.: Kitahiroshima Town Office, Environment and Lifestyle Division, Sewerage SectionTelephone: 0826-72-7365 Email address: gesuido@town.kitahiroshima.lg.jp A. Submission period From the day the request for submission of qualification confirmation documents is received until the submission deadline specified in the request (Monday, October 21, 2024), from 9:00 am to 5:00 pm every day (excluding holidays) B. Documents to be submitted (A) Qualification confirmation documents submission form (B) Company's construction track record, engineer's qualifications and construction experience report (C) Construction work performance certificate (application) form (?Only if construction track record is requested) (D) Copy of Schedule 2 of the Corporation Tax Return (Details regarding the determination of family-related parties, etc.) (E) Copy of the certificate of registered matters (within three months) (F) Copy of the notice of overall evaluation value of the business review C. Method and place of submission Registration on the electronic bidding system or in person (if in person, the place of submission is the Kitahiroshima Town Hall Financial Policy Division (2nd floor of the Kitahiroshima Town Hall Main Office) FY2024 10% FY2024 Works related to the renewal (enhancement of functionality) of machinery in the Kawaoda treatment district Target treatment district Kitahiroshima Town 1st phase (Kawaoda district) Target equipment [Machinery] [Electrical equipment] [Machinery] ?Automatic coarse screen ?Deodorizing fan ?Raw water pump tank water level gauge ?No. 2 relay pump No. 2 ?Crusher ?Ventilator ?No. 6 relay pump No. 1, 2 ?Raw water pump ?Emergency engine pump ?Submersible mixing pump ?Sprinkler pump ?Aeration blower ?Air supply fan Specifications Project name Agricultural village drainage project Route name Work name Kawaoda treatment district machinery renewal work Construction site Kawaoda district division Design amount Design change amount Change contract amount Work price Consumption tax equivalent amount Design amount Construction overview Kawaoda district agricultural village drainage treatment facility special specifications Kitahiroshima Town Chapter 1 Total The construction of the Kawaoda District Agricultural Village Sewage Project Functional Strengthening Measures Works will be based primarily on the Hiroshima Prefecture "Common Specifications for Civil Engineering Works, etc.", as well as the Public Buildings Association's "Standard Specifications for Public Building Works (Architectural Works)," "Standard Specifications for Public Building Works (Mechanical Equipment Works)," and "Standard Specifications for Public Building Works (Electrical Equipment Works)." Chapter 2 Contents of the Works 1. Purpose This work is to renew the facilities at the Kawaoda Water Quality Management Center and pump facilities as part of the Agricultural Village Sewage Project (Function Strengthening Measures) Kitahiroshima Town Phase 1 Area. This work will be a renewal work while the facilities are in service. 2. Construction Location Kitahiroshima Town Kawaoda Water Quality Management Center Relay Pumps 6 locations 3. Planned Outline of the Sewage Treatment Facility - Sewage to be Treated Domestic Sewage (Sleet and Domestic Miscellaneous Wastewater) - Planned Target Population to be Treated 910 people - Planned Sewage Volume 246 m3/day (average daily sewage volume) - Planned Water Quality Items Influent water quality Treated water quality BOD 200mg/? 20mg/? S S 200mg/? 50mg/? Model JARUS-III96 type Treatment method A combination of flow rate adjustment, anaerobic filter bed and contact aeration 4. Treatment process Disinfection tank Flow rate adjustment tank Supernatant sludge Automatic fine screen Aeration settling tank Sewage metering tank Anaerobic filter bed tank Sludge thickening storage tank Sludge storage tank Return water sludge Sludge discharge Transport Raw water pump tank Crusher Fine screen Sludge contact aeration tank Sedimentation tank Sprinkler pump Tank sprinkler Automatic coarse screen Automatic fine screen Bypass Bypass overflow 5. Scope of work The scope of work for the Kawaoda Water Quality Management Center is as follows: Mechanical equipment work (equipment renewal work, etc.) Electrical equipment work (equipment renewal work, etc.) The scope of work for the Kawaoda area relay pump is as follows: Mechanical equipment construction (equipment renewal construction, etc.) Chapter 3 Ensuring treatment performance 1. Ensuring treatment function ? The contractor shall obtain the consent of the supervising officer for the design of the detailed structure of the treatment facility, the selection and placement of machinery and equipment, etc., not specified in the design documents. In this case, the contractor shall be familiar with the plan outline and design documents of the sewage treatment facility in Chapter 2, paragraph 3, and endeavor to ensure the specified treatment performance. ? If the contractor has any doubts or suggestions for improvement regarding the structure, machinery, equipment, etc. of the sewage treatment facility shown in the design documents, he/she shall discuss and deal with them with the supervising officer. Chapter 4 Construction period The construction period of this work includes a 13-day inspection period. Chapter 5 Construction organization register The contractor shall prepare a construction organization register by adding Attachment 1 (Engineer Register) and prepare it at the construction site and submit it to the supervising officer. In addition, the form shall include the face photos, names, and company names of the supervising engineer, chief engineer (including subcontractors), and specialized engineers. In addition, the type of work that subcontractors are responsible for must be clearly indicated in the common specification format for the construction site accident prevention council and construction system diagram. Chapter 6 Site Management Contractors must have supervising engineers and chief engineers (including subcontractors) wear name tags with the name of the project, construction period, photograph, the name of the company they belong to, and a certification seal while on the construction site. (Name tag format) Supervising (Chief) Engineer's Name ? ? ? ? ? ? ? Construction - Paper size must be business card size or larger - Stamp must be the company seal of the company Construction period From XX year XX month XX day - Photo size must be approximately 2 cm x 3 cm. To XX/XX/XX ? ? Construction Co., Ltd. Seal Chapter 7 Creation and Registration of Construction Charts For construction works with a contract price of 5 million yen or more at the time of order or change, contractors must create a "Construction Chart" as construction performance information at the time of order, change, completion, and correction based on the Construction Performance Information Service (CORINS), and after confirmation by the supervising staff, register it with the registration agency within 10 days from the date of contract conclusion when order is received, and within 10 days from the date of contract conclusion when changes or corrections are made to the registered contents. (However, for construction works with a contract price of 5 million yen or more2,For construction projects of less than 5 million yen, registrations shall be made only at the time of order acceptance or correction. ) Also, when the "Construction Chart Receipt" is received, a copy shall be submitted immediately to the supervising officer. Chapter 8 Construction Conditions 1. Process Restrictions None 2. Partial Delivery None Chapter 9 Site Conditions 1. Related Construction None 2. Measures against Third Parties None 3. Facility Operation This construction is a renewal construction while the facility is in service. Therefore, close contact with the facility's septic tank management company and septic tank cleaning company must be maintained, and care must be taken not to disrupt the facility's operation. Chapter 10 Local Information Sessions The contractor shall hold "local information sessions" before and during the construction of the construction as necessary, and shall endeavor to obtain the cooperation of residents by explaining the contents of the construction, construction time, environmental measures, etc. Chapter 11 Power for Construction The contractor shall bear the power equipment and power charges used for this construction. Since this construction is a renewal construction while the facility is in service, the city shall bear the operation costs of the facility itself and the costs of sludge removal. Chapter 12 Construction Materials 1. Mechanical and Electrical Equipment Construction (1) All materials or parts used in the manufacture of mechanical and electrical equipment must conform to the following standards and regulations. Japan Industrial Standards (JIS), Japan Electrical Standards Committee Standards (JEC), Japan Electrical Manufacturers' Association Standards (JEM), Water Supply and Drainage Air Conditioning Equipment Standards, Sewage Septic Tank Construction Standards, and other relevant laws and regulations. (2) For machinery and electrical equipment manufactured in a factory, manufacturing drawings must be prepared and the equipment must be manufactured with the approval of the supervising official. (3) For general-purpose products such as prime movers, pumps, and blowers, the approval of the supervising official must be obtained by attaching the manufacturing factory test results sheet and certificate of approval. (4) The specifications of mechanical equipment shall be as specified in the attached "Specifications of Mechanical Equipment". (5) The specifications of electrical equipment shall be as specified in the attached "Specifications of Electrical Equipment". Chapter 13 Construction 1. Mechanical and Electrical Equipment Construction (1) All mechanical equipment shall be painted, except for stainless steel and resin products, and general-purpose products such as motors, pumps, and blowers. Painting specifications shall be in accordance with the "Standard Specifications for Public Building Construction (Mechanical Equipment Construction)". (2) The installation and layout of mechanical and electrical equipment shall be carried out with a thorough understanding of the design documents and the site, with any doubts clarified, and with a detailed understanding of the contents, so that the performance of the treatment facility can be fully demonstrated. (3) When valves are installed using a screw-in type, nipple unions or other devices shall be used to install the valves in a manner that allows them to be detached. 2. Maintenance and Management Maintenance and management of the treatment facility after its completion shall be carried out through a system that combines patrol management by a maintenance and inspection contractor and daily inspections by a management association organized by the beneficiaries. Therefore, the contractor shall endeavor to ensure that the treatment facility corresponds to the actual maintenance and management conditions and is safe. Chapter 14 Construction Management 1. Construction management Contractors shall manage construction in accordance with the common specifications shown in Chapter 1 and in compliance with the "Inspection and Construction Management Index for Agricultural Village Sewerage Facilities (draft)" (National Review Committee for the Preparation of Agricultural Village Sewerage Project Standards, etc.). 2. Construction Record Photography (1) According to the construction order of the work, record photographs must be prepared as instructed by the supervising staff or as necessary, and submitted after the work is completed. For places that cannot be confirmed later, such as buried places, they must be submitted to the supervising staff at the stage of moving to the next process for confirmation. (2) When taking photographs, blackboards indicating the location, type of structure, number, etc. must be set up, and dimensions, etc. must be indicated using a scale, etc. (3) Photographs should be taken in color and service versions as a general rule, and the photo album should be an A4-sized album. Chapter 15 Water-flow trial operation, etc. 1. Upon completion of construction, a trial run of each device must be conducted to confirm that each device is operating normally. 2. Water-flow and air-flow tests, as well as water pressure and air-tight tests must be conducted on the piping equipment to confirm that there are no incorrect piping or leaks. 3. The trial run shall be conducted in accordance with the Water Flow Trial Run Procedures etc. Manual prepared in advance in consultation with the Supervising Officer. 4. Appropriate personnel must be assigned to conduct the trial run of each piece of equipment during the trial run. 5. The Supervising Officer must be present during the trial run. Chapter 16 Items to be Submitted at Completion Upon completion of the work, the Contractor shall prepare and submit the following documents. (1) As-built drawings (completion drawings) of the work (2) Documents necessary for the maintenance and management of the treatment facility (design specifications and operation manuals for mechanical and electrical equipment, etc.) (3) Specifications, supplier records, catalogs, etc. for each piece of machinery and equipment (4) Any other documents as instructed by the Supervising Officer Chapter 17 Procedures with Government Agencies, etc. The Contractor shall carry out all procedures with the relevant government agencies, NTT and the electric power company, and shall maintain close contact at all times to ensure that there are no hindrances to the start of electricity use. The costs required for this shall be borne by the Contractor. Chapter 18 Supplementary explanation for changes in conditionsWhen natural or artificial construction conditions differ from those in the design documents, or when special unforeseen construction conditions not specified in the design documents occur, the main items that are considered to be changes in construction conditions are as follows: - Foundation geology - Soil quality of excavated soil - Drainage volume - Appearance of underground buried objects (including buried cultural properties) - Soil disposal sites and transportation roads Chapter 19 Unspecified mattersIf any matters not specified in these specifications or any doubts arise regarding the construction of this work, they shall be discussed with the supervising officials as necessary. Construction Structure Register Form (Engineer Register) Appendix 1 Construction Engineer Register Name of Prime Contractor Company Name Company Name Company Name Company Name Company Name?Name of Supervising Engineer ?Name of Chief Engineer ?Name of Chief Engineer ?Name of Chief Engineer ?Name of Chief Engineer Date of Birth Date of Birth Date of Birth Date of Birth Date of BirthFull-time ? Non-full-time Full-time ? Non-full-time Full-time ? Non-full-time Full-time ? Non-full-time [Photo attachment column] [Photo attachment column] [Photo attachment column] [Photo attachment column] [Photo attachment column] Company Name Company Name Company Name Company Name Company Name?Name of Chief Engineer ?Name of Chief Engineer ?Name of Chief Engineer [Notes] Date of Birth Date of Birth Date of Birth Date of BirthFull-time ? Non-full-time Full-time ? Non-full-time Full-time ? Non-full-time Full-time ? Non-full-time *Photos to be attached should be arranged vertically. 3cm width 2.The photo should be approximately 1.5cm in size and the face should be recognizable. Company NameCompany NameCompany NameCompany NameCompany Name?Name of Chief Engineer?Name of Chief Engineer?Name of Chief Engineer?Name of Chief EngineerDate of BirthDate of BirthDate of BirthDate of BirthDate of BirthThis form should be made in duplicate, one copy kept and the other submitted. Full-time ? Non-full-time Full-time ? Non-full-time Full-time ? Non-full-time Full-time ? Non-full-time However, if a color copy is used, a color copy must be submitted. Also, if a digital camera was used, a printout is acceptable. [Photo attachment column] [Photo attachment column] [Photo attachment column] [Photo attachment column]Specifications for Mechanical Equipment at the Kawaoda District Treatment Facility in Kitahiroshima Town Section 1 Automatic Coarse Screen (Updated)1. Purpose of UseThis device is installed to remove large impurities from the inflowing wastewater and prevent the deterioration of the functionality of various downstream equipment.This device is installed to remove large impurities from the inflowing wastewater and prevent the deterioration of the functionality of various downstream equipment. 2. Specifications1) : Automatic scraping type2) : 1 unit3) : Waterway width, machine length4) : 50 mm5) : m3/hour (maximum amount of wastewater per hour)6) : Outdoor submerged type Induction motor with reducer, insulation type E or higher, kW or less (3?200V 60Hz)3. Materials of main parts1) Frame: SUS3042) Scraper: SUS3043) Screen: SUS3044) Wheels and belts: Resin (polyurethane, etc.)5) : Stainless steel, carbon steel for mechanical construction4. Accessories1) Guide plate: SUS304 1 set2) Mounting bracket: SUS304 1 set3) Sediment basket: SUS304 2 pieces4) Sealing rubber5. Testing and inspectionTest and inspection shall be carried out according to the manufacturer's specifications, and an inspection report and mill sheet shall be submitted.6. Special notesPay attention to the connection with the following equipment.1) Automatic coarse screen cover2) Sediment basket, sediment basket support7. Reference1) Existing equipment Manufacturer: ShinMaywa Industry Co., Ltd.2) Model number: VS-2H Sprocket/chain type Number Quantity Shape and dimensions 500mm 1,500mm Mesh width Processing capacity 29.6 Motor 0.025Section 2 Crusher (renewal)1. Purpose of useThis device is installed to prevent blockage of downstream pumps by breaking up and crushing impurities in the inflowing wastewater, to make it easier to handle the screen residue removed by the automatic fine screen, and to stabilize the downstream biological treatment.2. Specifications1): Rotating drum type (controlled type)2): 1 unit3): m3/hour (maximum wastewater volume per hour)4): Outdoor submerged vertical induction motor, insulation class E or higher, kW or less (3?200V 60Hz)3. Main parts materials1) Casing: FC2502) Shaft/drum: SCM415/SUS3033) Fixed teeth/cutter bar: SKD4) Cutting teeth: SCS/K104. Accessories1) Inlet short pipe: FC200 1 set2) Foundation bolt: SUS304 1 set3) Other required items: Chrysanthemum flange5. Other1) Paint: Anticorrosive paint (manufacturer's standard)2) Removal of existing equipment: Removal of inlet piping6. Testing and inspectionTest and inspection will be conducted according to the manufacturer's specifications, and an inspection report and mill sheet will be submitted.7. Reference1) Existing equipment manufacturer: ShinMaywa Industries Co., Ltd.2) Model number: SC150 type (control type)8. Special notesThe manufacturer of the existing equipment has stopped selling this equipment, and for replacement, an equivalent product from the manufacturer below is assumed. Equipment manufacturer: Comminutor Service Co., Ltd. Equipment type: 7R submerged type (control type) Motor 0.20 type Number of units Processing capacity 29.6 Section 3 Raw water pump (renewal)1. Purpose of use This device is installed to pump inflowing sewage to the downstream flow adjustment tank. 2. Specifications 1) : Submersible vortex type sewage and wastewater pump (vortex) 2) : 2 units 3) : ? 80 mm 4) : m3/min 5) : m 6) : Dry-type submersible induction motor, insulation class E or higher, kW or less (3? 200V 60Hz 4-pole direct start) 3. Main parts materials 1) Casing/impeller: FC200 2) Shaft: SUS420J2 or SUS4034. Accessories1) Attachment/detachment device: FC200 1 set (reuse of existing equipment)2) Foundation bolt: SUS304 1 set (reuse of existing equipment)3) Guide pipe: SUS304 1 set (reuse of existing equipment)4) Guide holder: SUS304 1 set (reuse of existing equipment)5) Lifting chain: SUS304 1 set (reuse of existing equipment)6) Hook: SUS304 2 sets (reuse of existing equipment)7) Underwater cable5. Paint1) Paint: Anticorrosive paint (manufacturer's standard)6. Testing/inspection Testing/inspection will be conducted according to the manufacturer's specifications in accordance with JIS-B-8301, and an inspection report and mill sheet will be submitted.7. Special notes1) The shaft seal will use a double mechanical seal, with shaft seal oil sealed in the middle. 2) In principle, the weight of the rotating part and hydraulic thrust are supported by the motor bearings. 8. References 1) Existing installation Manufacturer: ShinMaywa Industry Co., Ltd. 2) Model number: CV80-P80BS Motor 2.20 Model No. Volume Diameter Pumping volume 0.5 Total head 7.5 Section 4 Emergency engine pump (renewal) 1. Purpose of use This device is installed to transfer sewage that flows into the raw water pump tank during a power outage to the downstream flow adjustment tank. It is also used as an auxiliary for the raw water pump in the event of an abnormal inflow. 2. Specifications 1) : Horizontal shaft non-blocking self-contained sewage and waste pump 2) : 1 unit 3. Pump specifications 1) : ? 80mm 2) : m3/min 3) : m4. ? FC200?ADC?AC2) ? FC200?FCD450??3) ENGINE BODY ? FC200?AC7?Accessories1) Strainer ? 1 set2) Foundation bolt ? SUS304 1 set3) Engine start panel ? 1 set4) Battery ? 1 set5) Flexible exhaust pipe ? 1 set8?Painting1) Paint ? Corrosion-resistant paint (manufacturer's standard)9? Testing and Inspection Testing and inspection shall be carried out in accordance with the manufacturer's specifications in accordance with JIS-B-8301, and an inspection report and mill sheet shall be submitted. Model Quantity Diameter Pumping volume 0.5 Total head 7.5 Model Rated output Battery Fuel used Type Starting method 10. Reference 1) Existing installation Manufacturer: ShinMaywa Industries Co., Ltd. 2) Model number: ASE80SK Section 5 Submersible mixing pump (renewal) 1. Purpose of use This device is installed in a flow adjustment tank to mix the wastewater in the tank, homogenize the water quality, prevent sedimentation, and prevent spoilage and odor generation. 2. Specifications1): Submersible vortex pump with diffuser2): 2 units3): ? 80 mm4): m3/unit (width 3.40m x length 4.80m x depth 3.50m x 2 rooms)5): Dry-type submersible induction motor, insulation class E or higher, kW or lower (3?200V 60Hz 4-pole direct start)3. Materials of main parts1) Casing: FC200 or equivalent or higher2) Shaft: SUS420 J2 or equivalent or higher3) Impeller: FC200 or equivalent or higher4) Diffuser: FC200 or equivalent or higher (reuse of existing equipment)4. Accessories1) Attachment/detachment device: FC200 1 set (reuse of existing equipment)2) Foundation bolts: SUS304 1 set (reuse of existing equipment)3) Guide pipe: SUS304 1 set (reuse of existing equipment)4) Guide holder: SUS304 1 set (reuse of existing equipment)5) Lifting chain: SUS304 1 set (reuse of existing equipment)6) Hook: SUS304 1 set (reuse of existing equipment)7) Underwater cable8) Adjusting valve/silencer: Manufacturer's standard (reuse of existing equipment)5. Painting1) Painting: Manufacturer's standard specifications6. Testing/inspectionTesting/inspection will be conducted in accordance with JIS-B-8301 and manufacturer's specifications, and an inspection report and mill sheet will be submitted.7. Special notes1) A mechanical seal is used in the shaft seal, and shaft seal oil is sealed in the middle to prevent raw water from entering the motor. 2) In principle, the weight of the rotating part and hydraulic thrust are supported by the motor bearings. 8. Reference1) Existing installation manufacturer: ShinMaywa Industry Co., Ltd.2) Model number: JA22V2.20Model Quantity Orifice diameter Mixing volume 58.0Motor Section 6 Sprinkler pump (renewal)1. Purpose of useThis device is installed to pump treated water to sprinkler nozzles intended for defoaming and breaking up scum during the treatment process.2. Specifications1) : Submersible sewage pump2) : 1 unit3) : ? 50 mm4) : m3/min5) : m6) : Dry-type submersible induction motor, insulation class E or higher, kW or less (3? 200V 60Hz 2-pole direct start)3. Materials of main parts1) Casing/impeller: FC200 or special nylon resin2) Shaft: SUS420J2 or SUS403 or SUS3044. Accessories1) Attachment/detachment device: FC200 1 set (reuse of existing equipment)2) Foundation bolt: SUS304 1 set (reuse of existing equipment)3) Guide pipe: SUS304 1 set (reuse of existing equipment)4) Guide holder: SUS304 1 set (reuse of existing equipment)5) Lifting chain: SUS304 1 set (reuse of existing equipment)6) Hook: SUS304 1 set (reuse of existing equipment)7) Underwater cable5. Paint1) Paint: Anticorrosive paint (manufacturer's standard)6. Testing/inspection Testing/inspection will be conducted according to the manufacturer's specifications in accordance with JIS-B-8301, and an inspection report and mill sheet will be submitted.7. Special notes1) The shaft seal will use a double mechanical seal, with shaft seal oil sealed in the middle. 2) In principle, the weight of the rotating part and hydraulic thrust are supported by the motor bearings. 8. References 1) Existing installation Manufacturer: ShinMaywa Industries Co., Ltd. 2) Model number: AH501-P50S Motor 0.75 Model No. Quantity Orifice diameter Pumping volume 0.07 Total head 13.0 Section 7 Aeration blower (renewal) 1. Purpose of use This device is installed to supply air for aeration required for biological treatment, as well as air required for the air lift pump and air required for stirring the aeration sand settling tank and sludge storage tank. 2. Specifications 1) : Volumetric blower (Roots) 2) : 3 units 3) : ? mm 4) : m3/min 5) : kPa (mAq) 6) : Totally enclosed fan-cooled induction motor, insulation class E or higher, kW or less (3? 200V 60Hz) 3. Main Parts Materials1) Casing: FC2002) Housing: FC2003) Rotor: FCD5004) Shaft: S45C, FCD500, SCM4354. Accessories1) Base (with vibration isolation stand): 1 set2) Silencer (suction/discharge): 1 set3) Pulley, belt, belt cover: 1 set4) Safety valve: 1 piece5) Check valve: 1 piece6) Pressure gauge: 1 piece7) Expansion joint: 1 piece8) Anti-vibration rubber: 1 set9) Foundation bolt: 1 set5. Paint1) Paint: Heat-resistant paint (manufacturer's standard)6. Testing/InspectionTests and inspections will be conducted according to the manufacturer's specifications, and an inspection report and mill sheet will be submitted. 7. Reference1) Existing installationManufacturer: ShinMaywa Industry Co., Ltd.2) Model number: ARH65SModel numberVolumeOval65Air volume1.70Discharge pressure54.0 5.50Motor3.7Section 8 Air supply fan (renewal)1. PurposeThis device is installed to maintain the working environment of the pre-treatment room and perform hygienic maintenance.2. Specifications1) : Line fan2) : Pre-treatment room air supply3) : 1 unit4) : mm5) : m3/hour6) : Pa7) : 8) : Drip-proof typeMotor9) : kW10) : 1?100V 60Hz3. Main parts materials1) Casing: Cold-rolled steel plate SPCC2) Impeller: Cold-rolled steel plate SPCC4. Accessories1) Mounting materials: 1 set2) Anti-vibration joints: 1 set (2 pieces/unit)5. Painting1) Painting: Manufacturer's standard6. Testing/InspectionTesting/inspection shall be conducted according to the manufacturer's specifications in accordance with JIS-B-8330, and an inspection report and mill sheet shall be submitted.7. Reference1) Existing installationManufacturer: Ebara Corporation2) Model number: 3LFM26.3SPower supply installation position Horizontal installationMotor reference output 0.30Air volume 1,930Static pressure 150Model numberUse quantityConnection diameter 300Section 9 Deodorizing fan (renewal)1. Purpose of useThis device is installed to appropriately capture odors from the odor generating point and send them to a soil deodorizing device or release them outdoors.2. Specifications1) : Separate motor, belt-driven turbo fan2) : 1 unit3) : ?4) : m3/min5) : Pa6) : Drip-proof motor, insulation class E or higher, kW or less (3?200V 60Hz 4-pole, direct start)3. Materials of main parts1) Casing and impeller: Corrosion-resistant resin2) Impeller: Corrosion-resistant resin4. Accessories1) V-pulley: 1 set2) V-belt: 1 set3) Belt cover: 1 set4) Anti-vibration stand: 1 set5) Anti-vibration joint: Soft polyvinyl chloride or synthetic resin, 2 pieces6) Companion flange: 2 pieces7) Foundation bolt: SUS304, 1 set5. Paint1) Paint: Corrosion-resistant paint (manufacturer's standard)6. Testing and Inspection: Testing and inspection will be conducted according to the manufacturer's specifications in accordance with JIS-B-8330, and inspection reports and mill sheets will be submitted. 7. Reference 1) Existing installation manufacturer: Seiko Chemical Engineering Co., Ltd. 2) Model number: FTF152-RH1-B10.0 Wind pressure 1,180 Motor 0.Model 75 Quantity Connection pipe diameter 200mm Air volume Item 10 Ventilation fan (renewal) 1. Purpose of use This device is installed to ventilate each room to keep the work environment good and to perform hygienic maintenance. 2. Specifications 1) : Pressurized ventilation fan 2) : Screen room 3) : 4) : Unit 5) : mm 6) : m3/hour 7) : Pa 8) : W 9) : 1 ?100V 60Hz 10) : EWF-35CSA2 3. Main parts materials 1) Frame: Cold rolled steel plate SPCC 2) Impeller: Cold rolled steel plate SPCC 4. Accessories1) Mounting screws: SUS304 1 set2) Protective guard: 1 set according to the material of the main body3) Mounting frame: Wooden frame or SUS304 1 set (if necessary)5. Painting1) Painting: Manufacturer's standard6. Testing and inspection Testing and inspection shall be performed according to the manufacturer's specifications in accordance with JIS-B-8330, and an inspection report and mill sheet shall be submitted.Air volumeStatic pressureReference outputPower supplyReference part number (Mitsubishi)100502,0003501ModelNumber of places of useVolumeApertureDiameterUseExhaustGasOda District Treatment FacilityElectrical Equipment SpecificationsKitahiroshima TownChapter 1 General1-1. Application?This specification applies to the electrical equipment construction of the Agricultural Village Drainage Project Kawaoda District Functional Strengthening Measures.? This work shall be carried out after the approval drawings have been decided based on these specifications, related specifications and design documents. 1-2. Work location Kawaoda Water Quality Management Center, Kawaoda, Kitahiroshima Town 1-3. Applicable standards The design and manufacture of the equipment shall comply with the following standards and related laws in addition to the matters described in these specifications. ? Japan Industrial Standards (JIS), Institute of Electrical Engineers of Japan Electrotechnical Committee Standards (JEC), Japan Electrical Manufacturers' Association Standards (JEM), Japanese Electric Wire & Cable Makers' Association Standards (JCS), Electrical Equipment Technical Standards (Ministry of International Trade and Industry Ordinance), Building Standards Act, Fire Service Act, Ministry of Land, Infrastructure, Transport and Tourism Public Works Department "Standard Specifications for Public Building Works (Electrical Equipment Works)", Japan Sewage Works Agency Design Standards (draft), Other relevant laws, regulations and standards 1-4. Work overview This work will renew part of the electrical equipment used to operate the wastewater treatment facility at Kawaoda Water Quality Management Center. 1-5. Work scope The following equipment shall be manufactured, installed and adjusted for operation.? Instrumentation equipment (update of immersion pressure type water level gauge) ? Other necessary work Chapter 2 Equipment specifications 2-1. Instrumentation equipment 1. Overview This equipment will be installed to measure the water level, flow rate, and water quality required for monitoring and operating the facility. Furthermore, arresters will be installed on the signal lines and power lines of the instrumentation installed outdoors to provide lightning protection measures. 2. Equipment configuration ? Immersion pressure type water level gauge 1 set 3. Detailed specifications? Immersion pressure type water level meter1) Use: Measuring the water level of raw water pump tank2) Accuracy: Within �2%FS (combined accuracy)3) Materials: Element: SUS304, 316, 316L, Wetted parts: SUS304, 3164) Specifications: Measurement range: 0-3m, Contact output: 5 points or more5) Water level output: DC 4-20mA or 1-5V6) Power supply: AC 100V7) Accessories: Hanging equipment, dedicated cable, display, converter, other necessary items8) Existing equipment: Aichi Tokei Denki Co., Ltd.AMLP Chapter 3 Installation and wiring work3-1. General mattersThe installation and wiring work and the process of this work must be discussed in advance with the supervising staff and carried out according to their instructions.3-2. Installation work?The equipment in each chapter must be firmly installed in the designated location according to the drawings. - Installation will be carried out under the guidance of experienced engineers from each equipment manufacturer. - Concrete construction will require the consent and instructions of staff regarding concrete mix, formwork, curing, etc. 3-3. Electrical wiring work - All wiring will be laid in conduits or cable racks. - Grounding work must be carried out for each piece of equipment, steel conduits, boxes, and other necessary locations. Kitahiroshima Town Kawaoda District Pump Facility Machinery and Equipment Specifications, Section 2, No. 2 Relay Pump (Renewal) 1. Purpose of Use This device will be installed to pump sewage that flows into the No. 2 relay pump station to the subsequent relay pump station. 2. Specifications1): Submersible vortex type sewage and wastewater pump (Vortex)2): 1 unit (No. 2 updated)3): ? 65 mm4): m3/min5): m6): Dry type submersible induction motor, insulation class E or higher, kW or less (3?200V 60Hz 4-pole direct start)7): Auto cut or thermal protector3. Main parts materials1) Casing/impeller: FC2002) Shaft: SUS420J2 or SUS4034. Accessories1) Detachable device: FC200 1 set/unit (reuse of existing equipment)2) Foundation bolt: SUS304 1 set/unit (reuse of existing equipment)3) Guide pipe: SUS304 1 set/unit (reuse of existing equipment)4) Guide holder: SUS304 1 set/unit (reuse of existing equipment)5) Lifting chain: SUS304 1 set/unit (reuse of existing equipment)6) Hook: SUS304 1 set/unit (reuse of existing equipment)7) Suction nozzle: SUS304 1 set/unit8) Check valve: SUS304 1 set/unit (reuse of existing equipment)9) Ball valve: SUS304 1 set/unit (reuse of existing equipment)10) Underwater cable: 1 11) Inlet baffle: SUS304 1 set/tank (reuse of existing equipment) 12) In-tank piping: SUS304 1 set/tank (reuse of existing equipment) 5. Painting 1) Painting: Anticorrosive paint (manufacturer's standard) 6. Testing and inspection Testing and inspection shall be conducted according to the manufacturer's specifications in accordance with JIS-B-8301, and an inspection report and mill sheet shall be submitted. 7. Special notes 1) The shaft seal shall use a double mechanical seal, with shaft seal oil sealed in the middle. 2) In principle, the weight of the rotating part and hydraulic thrust shall be supported by the motor bearings. 8. References 1) Existing installation Manufacturer and model number ShinMaywa Industries Co., Ltd. CVL501-P65B Motor 0.75 Protective device Model Number Quantity Diameter Pumping volume 0.185 Total head 2.1. Section 6 No. 6 Relay Pump (Renewal)1. Purpose of UseThis device is installed to pump wastewater that has flowed into the No. 6 relay pump station to the downstream relay pump station.2. Specifications1): Submersible vortex type wastewater and sewage pump (vortex)2): 2 units3): ? 65 mm4): m3/min5): m6): Dry-type submersible induction motor, insulation class E or higher, kW or less (3? 200V 60Hz 4-pole direct start)7): Auto cut or thermal protector3. Materials of main parts1) Casing/impeller: FC2002) Shaft: SUS420J2 or SUS4034. Accessories1) Detachable device: FC200 1 set/unit (reuse of existing equipment)2) Foundation bolt: SUS304 1 set/unit (reuse of existing equipment)3) Guide pipe: SUS304 1 set/unit (reuse of existing equipment)4) Guide holder: SUS304 1 set/unit (reuse of existing equipment)5) Lifting chain: SUS304 1 set/unit (reuse of existing equipment)6) Hook: SUS304 1 set/unit (reuse of existing equipment)7) Suction nozzle: SUS304 1 set/unit8) Check valve: SUS304 1 set/unit (reuse of existing equipment)9) Ball valve: SUS304 1 set/unit (reuse of existing equipment)10) Underwater cable: 1 sets/unit11) Inlet baffle: SUS304 1 set/tank (reuse of existing equipment)12) Piping inside tank: SUS304 1 set/tank (reuse of existing equipment)5. Painting1) Painting: Anti-corrosion paint (manufacturer's standard)6. Testing and inspection Testing and inspection will be carried out according to manufacturer specifications in accordance with JIS-B-8301, and an inspection report and mill sheet will be submitted.7. Special notes1) The shaft seal will use a double mechanical seal, with shaft seal oil sealed in between.2) As a general rule, the weight of the rotating part and hydraulic thrust will be supported by the motor bearings.8. Reference 1) Existing installation Manufacturer and model number ShinMaywa Industry Co., Ltd. CVL651-P65G Motor 1.50 Protection device type Sets Quantity Orifice diameter Pumping volume 0.487 Total head 3.4 � Yen Item number Mechanical equipment work Processing facility (Kawaoda area) Sets 1.0 M-1 Electrical equipment work Processing facility (Kawaoda area) Sets 1.0 E-1 Mechanical equipment work Pump facility (Kawaoda area) Sets 1.0 MP-1 Subtotal Consumption tax equivalent % 10 Contract construction cost estimate Standard and dimensions Unit Quantity Unit price Amount Remarks No. 1 Contract construction cost estimate name � Yen Item number Mechanical equipment work Processing facility (Kawaoda area) Sets 1.0 Quantity Standard and dimensions Remarks No. M-1 Unit price Amount Name Name Contract work cost statement Unit � Yen Statement No. Electrical equipment work Treatment facility (Kawaoda area) Sets 1.0 Total No. E-1 Contract work cost statement Name Name Specification/dimension Unit Quantity Unit price Amount Remarks � Yen Statement No. Mechanical equipment work Pump facility (Kawaoda area) Sets 1.0 Total No. MP-1 Name Name Specification/dimension Unit Quantity Unit price Amount Contract work cost statement Remarks Drawing No. Work name Drawing name Dimensions Work location Construction year Contractor Kitahiroshima Town Yamagata County Kitahiroshima Town 1 NON 2024 Flow sheet Agricultural village drainage project Kawaoda area Functional enhancement measures Construction Management room Power control panel Instrumentation panel construction scope Mechanical equipment ? Automatic coarse screen (renewed) ? Crusher (renewed) ? No.1 raw water pump (renewed) ? No.2 raw water pump (renewed) ? Emergency engine pump (renewed) ? No.1 submersible mixing pump (renewed) ? No.2 submersible mixing pump (renewed) ? Sprinkler pump (renewed) ? No.1 aeration blower (renewed) ? No.2 aeration blower (renewed) ? No.3 aeration blower (renewed) ? Air supply fan (renewed) ? Deodorizing fan (renewed) ? Screen room exhaust fan (renewed) Electrical equipment ? Raw water pump tank water level gauge (renewed) ? Sprinkler pump (renewed) ? No.2 submersible mixing pump (renewed) ? No.1 submersible mixing pump (renewed) ??Raw water pump (renewed) No.1 & 2?Raw water pump tank water level gauge (renewed)?Crusher (renewed)?Automatic coarse screen (renewed)?Emergency engine pump (renewed)?Deodorizing fan (renewed)?Screen room exhaust fan (renewed)?Air supply fan (renewed)?No.1 aeration blower (renewed)?No.2 aeration blower (renewed)?No.3 aeration blower (renewed)?Integrated recorder (separate)?Load amount calculator (separate)?UV meter (separate)Drawing numberProject nameDrawing nameDimensionsProject locationProject yearProject location1:50 2Kitahiroshima TownYamagata DistrictKitahiroshima TownFY2024 Agricultural Village Drainage ProjectKawaoda District Floor plan of lower part of functional strengthening work Construction scope Mechanical equipment ? Automatic coarse screen (renewed) ? Crusher (renewed) ? No.1 raw water pump (renewed) ? No.2 raw water pump (renewed) ? Emergency engine pump (renewed) ? No.1 submersible mixing pump (renewed) ? No.2 submersible mixing pump (renewed) ? Sprinkler pump (renewed) ? No.1 aeration blower (renewed) ? No.2 aeration blower (renewed) ? No.3 aeration blower (renewed) ? Air supply Fan (renewed) ? Deodorizing fan (renewed) ? Screen room exhaust fan (renewed) Electrical equipment ? Raw water pump tank water level gauge (renewed) ? Crusher (renewed) ? Emergency engine pump (renewed) ? Sprinkler pump (renewed) ? No. 1 raw water pump (renewed) ? No. 2 raw water pump (renewed) ? No. 2 submersible mixing pump (renewed) ? No. 1 submersible mixing pump (renewed) ? Raw water pump tank water level gauge (renewed) ? UV meter (separate) Drawing number Project name Drawing name Dimensions Construction location Construction year Project owner Kitahiroshima Town Yamagata County Kitahiroshima Town 3 1:50 Top plan view FY2024 agricultural village drainage project Kawaoda area Scope of work for functional enhancement measuresMachinery and equipment? Automatic coarse screen (renewed)? Crusher (renewed)? No.1 raw water pump (renewed)? No.2 raw water pump (renewed)? Emergency engine pump (renewed)? No.1 submersible mixing pump (renewed)? No.2 submersible mixing pump (renewed)? Sprinkler pump (renewed)? No.1 aeration blower (renewed)? No.2 aeration blower (renewed)? No.3 aeration blower (renewed)? Air supply fan (renewed)? Deodorizer Fan (renewed) ? Screen room exhaust fan (renewed) Electrical equipment ? Raw water pump tank water level gauge (renewed) ? Deodorizing fan (renewed) ? Air supply fan Fan (renewed) (renewed) ? Screen room exhaust fan ? No. 2 aeration blower (renewed) ? No. 1 aeration blower (renewed) ? No. 3 aeration blower (renewed) ? UV meter (separate) ? Portable pump outlet panel (separate) ? Load calculator (separate) ? Accumulator recorder (separate) Drawing number Project name Drawing name Dimensions Construction location Construction year Project entity 4 Kitahiroshima Town Yamagata County Kitahiroshima Town 1:50 Equipment C-C cross section FY2024 agricultural village drainage project Kawaoda area Scope of work for functional enhancement measuresMachinery and equipment? Automatic coarse screen (renewed)? Crusher (renewed)? No.1 raw water pump (renewed)? No.2 raw water pump (renewed)? Emergency engine pump (renewed)? No.1 submersible mixing pump (renewed)? No.2 submersible mixing pump (renewed)? Sprinkler pump (renewed)? No.1 aeration blower (renewed)? No.2 aeration blower (renewed)? No.3 aeration blower (renewed)? Air supply fan (renewed)? Deodorizing fan (renewed)? Screen room exhaust fan (renewed)Electrical equipment? Raw water pump tank water level gauge (renewed)? No.1 aeration blower (renewed) (renewed)? No.2 submersible mixing pump? Crusher (renewed)? Sprinkler pump (renewed)? Raw water pump tank water level gauge (renewed)? No.1 raw water pump? No.2 Raw water pump ? Total recorder (separate) ? Load calculator (separate) ? UV meter (separate) Drawing number Project name Drawing name Dimensions Construction location Construction year Construction location Kitahiroshima Town Yamagata County Kitahiroshima Town FY2024 Agricultural village drainage project Kawaoda area Functional enhancement measures construction 5 NON Crusher renewal plan Construction scope Crusher (existing equipment) Crusher (renewal equipment) Existing crusher (ShinMaywa Industry Co., Ltd. SC150M) Updated crusher (Community Provider Service Co., Ltd. 7R submerged type (control type)) Mechanical equipment ? Automatic coarse screen (updated) ? Crusher (updated) ? No.1 raw water pump (updated) ? No.2 raw water pump (updated) ? Emergency engine pump (updated) ? No.1 submersible mixing pump (updated) ? No.2 submersible mixing pump (updated) ? Sprinkler pump (updated) ? No.1 aeration blower (updated) ? No.2 aeration blower (updated) ? No.3 aeration blower (updated) ? Air supply fan (updated) ? Deodorizing fan (updated) ? Screen room exhaust fan (updated) Electrical equipment ? Raw water pump tank water level gauge (updated) 135 240Cutting the existing inlet pipeRemoving the existing crusherRemoving the existing crusherInstalling the existing outflow pipe for flowing waterReplacing the crusher for flowing waterReplacing the existing outflow pipeReplacing the existing outflow pipeThree types of scraping, epoxy resin paintExisting inflow pipeReplacing the paint, above the three types of scraping, epoxy resin paintExisting outflow pipeReplacing the paint, above the three types of scraping, epoxy resin paintThree types of scraping, epoxy resin paintExisting inflow pipeReplacing the paint, above the three types of scraping, epoxy resin paint*This drawing is enlarged. (Original drawing size A4) Drawing number Project name Drawing name Scale Construction location Construction year Project owner Kitahiroshima Town Yamagata County Kitahiroshima Town 1:20000 Location map Agricultural village drainage project Kawaoda district Functional enhancement measures project Reiwa 6 7S=1;20,0000 500 Kitahiroshima Town Kawaoda district Location map Kawaoda Water Quality Management Center No. 1 relay pump station No. 6 relay pump No. 5 relay pump No. 4 relay pump No. 3 relay pump No. 2 relay pump (separate) (updated) (separate) (separate) (updated) PPPPPP treatment facility Pump facility Legend P station Drawing number Drawing name Scale Construction location Project name Construction year Project owner Kitahiroshima Town *This drawing has been reduced in size. (Original drawing size A1) Yamagata County Kitahiroshima Town Agricultural Village Drainage Project Kawaoda District Functional Enhancement Measures Construction Reiwa 6 1:20 Pump No. 2 detailed drawing 9 Construction area layout drawing S=NON MH Number Type Quantity Diameter (mm) Pumping volume (m3/min) Head (m) Output (kW) Vortex 65 0.185 2.1 0.75 No. 2 1 Model number Notes Dedicated cable extension (m) 25 Installed manufacturer Shinmaywa Industry CVL501 Updated NO. 2 Relay pump (renewal) Inlet switchboard Control panel No. 2 Relay pump station No. 2 No. 2 Relay pump (renewal) No. 2 Relay pump (renewal) [Pump facility] ? No. 2 Relay pump No. 2: Main unit renewal ? No. 6 Relay pump No. 1 & 2: Main unit renewal Drawing number Drawing name Scale Construction location Construction name Construction year Project owner Kitahiroshima Town *This drawing has been reduced in size. (Original drawing size A1)Yamagata-gun Kitahiroshima-cho Agricultural Village Drainage Project Kawaoda District Functional Strengthening Measures Construction FY2024 1:20 No. 6 Pump Details 13 Construction Area Layout S=NONMH Number Type Quantity Diameter (mm) Pumping Volume (m3/min) Head (m) Output (kW) Vortex 65 0.487 3.4 1.5 No. 6 2 Model Number Remarks Installation Manufacturer ShinMaywa Industry CVL651 Dedicated Cable Extension (m) 10 No. 6 Relay Pump Station Control Panel Inlet Switchgear Panel No. 1 & 2 No. 6 Relay Pump (Renewal) No. 1 & 2 No. 6 Relay Pump (Renewal) [Pump Facility] ? No. 2 Relay Pump No. 2: Main Unit Renewal ? No. 6 Relay Pump No. 1 & 2: Main Unit Renewal
NAICS
-
CPVS
-
UNSPSC
-
Regions
APEC Countries Asia Eastern Asia
Sectors
Civil Works Building Environment and Pollution-Recycling Automobiles and Auto Parts Non-Renewable Energy Supply Stainless Steel and Galvanized Human Resource-HR Security Services Architecture Bridges and Tunnels Engineering Roads and Highways-Bridge Oil and Gas Telecommunications Water and Sanitation Law and Legal Environmental Work Printing and Publishing Services Roadways Plastic and Rubber Machinery and Equipments-M&E Defence and Security Electricity Construction Agriculture-Food and Beverages Energy-Power and Electrical Computer Hardwares and Consumables Steel Petroleum Products Electronics Building Material
URL
Share
To be notified
when a tender matching your filter is published
To Follow
Tenders
Add New Tender Alert
To Follow
Contracts
Add New Contract Alert
To Follow
Fairs
Add New Fair Alert
Similar Tenders