Sign up now to have the right to view
50 tenders for free.
Title |
1 unit NBS HEARING MACHINE for CLLMMH-Siaton (N-1929-2024) PROVINCE OF NEGROS ORIENTAL |
|||
---|---|---|---|---|
You can sign up and unlock it for freeAccess to Public and Private Sector Business Opportunities for 200+ Countries |
||||
Country | ||||
Language | English | |||
Organization | ||||
Published Date | 25.10.2024 | |||
Deadline Date | 30.10.2024 | |||
Overview |
1 unit NBS HEARING MACHINE for CLLMMH-Siaton (N-1929-2024) Request for Quotation (RFQ) Reference Number 11399518 Procuring Entity PROVINCE OF NEGROS ORIENTAL Title 1 unit NBS HEARING MACHINE for CLLMMH-Siaton (N-1929-2024) Area of Delivery Negros Oriental Printable Version Solicitation Number: N-1929-2024 Trade Agreement: Implementing Rules and Regulations Procurement Mode: Negotiated Procurement - Small Value Procurement (Sec. 53.9) Classification: Goods Category: Hospital / Medical Equipment Approved Budget for the Contract: PHP 700,000.00 Delivery Period: 0 Day/s Client Agency: Contact Person: Michael E Fonollera Member, BAC Secretariat Ground Floor, Convention Hotel, Capitol Area, Dumaguete City Negros Oriental Philippines 6200 63-035-2263804 63-035-2251111 bac.secretariat.neg.or@gmail.com Status Active Associated Components Order Bid Supplements 0 Document Request List 0 Date Published 25/10/2024 Last Updated / Time 25/10/2024 12:00 AM Closing Date / Time 30/10/2024 1:00 AM Description 1 NBS HEARING MACHINE 1 UNIT 700,000.00 DEVICE MADSEN Alpha OAE+ is type 1077 from Natus Medical Denmark ApS. Dimensions Approx. 200 x 73 x 34 mm (7.9 x 2.9 x 1.3 inches) Weight Approx. 240 g (8.5 oz) excluding battery 280 g (9.9 oz) including battery Display Type: Color, TFT, touchscreen with adjustable LED backlight DIMENSIONS: 89.4MM (3.5 INCHES) Resolution: 240x320 pixels Keypad Resistive touchscreen (can be used with gloves) Sound Built-in speaker for key click and Pass/Clear Response and Refer/ No clear Response sounds Language settings Up to 7 user selectable languages available in selected language package Memory Patient memory capacity: Max. 250 patients Test memory capacity: Max. 500 test Battery Battery type: Rechargeable Li-ion 3.7 V/1800 mAh (6.7 Wh), fully charged DOCKING STATION PC interface Interface type: USB 2.0, Full-speed USB Power: Uses<100mA of current from the USB interface Printer/modem interface Interface type: RS232 Connector type: 6-pol Mini Din DC power input Input voltage: 5 V DC ±5% Max. power consumption when AccuScreen is docked: 5 VA(5V,1.0A) Max.power consumption when AccuScreen is not docked:0.25VA(5V,50mA) Power adapter Input voltage/range: 100-240 V AC, 50-60 Hz Output voltage: 5.0 V DC Output current: Minimum 1.0 A Mains plug types: US,UK,Europe and Australia Connectors OAE probe connector: 14 pin ODU Medisnap - For OAE+ Probe. Real time clock Integrated real time clock for time-stamping of measurements. The clock is automatically synchronized with PC clock when docked Accuracy: Max. deviation 12 minutes/year Backup: Min. 7 days, when battery is removed from unit Data interfaces PC: IR data transmission to docking station - USB interface from docking station to PC Label printer: IR data transmission to docking station - RS232 interface from docking station to label printer Modem: IR data transmission to docking station - RS232 interface from docking station to modem Transport and storage environment Temperature range: -20 - +60°C (-4 - 140°F) Humidity range: 10 - 90 % rel., non-condensing Air pressure:500 hPa to 1040 hP Operating environment Mode of operation: Continuous Temperature range: 10 - 40°C (50 - 104°F) Humidity range: 30 - 90 % rel., non-condensing Air pressure: 500 hPa* to 1060 hPa *At locations where the normal air pressure is below 800 hPa (at altitudes of more than 2000 meters), it is recommended to recalibrate the OAE probes and ABR ear coupler cable (if used) Warm-up time: < 20 seconds. Note: Warm-up time should be extended if MADSEN AccuScreen has been stored in a cold environment Measurement Techniques TEOAE Evaluation method: Noise-weighted averaging, counting of significant signal peaks Stimulus: Non-linear click sequence Stimulus level: 75 dB(A) ± 5 dB in 2 cc coupler, self-calibration depending on ear canal volume Click rate: 65-80 clicks per second (randomized) Input filter: 1 to 4 kHz Test display: Averaged waveform, no. of TEOAE peaks, probe fit assistant, noise level, anti- f act level,stability level and test progeress Result display: Averaged waveform, no. of TEOAE peaks and overall Pass/Clear Response or Refer/No Clear Response.On Refer/No Clear Response also probe fit assist-ant noise level' artifact level and stability level. DPOAE Evaluation method: Noise-weighted phase statistics Stimulus: Primary tone pair, F2/F1 = 1.24 Available test frequencies: F2 = 1, 1.5, 2, 3, 3.5, 4, 5 and 6 kHz Default test frequencies: F2 = 2, 3, 4 and 5 kHz (Pass/Clear Response at 3 out of 4) Available test levels: L1/L2 = 60/50 dB SPL and L1/L2 = 65/55 dB SPL Default test level: L1/L2 = 60/50 dB SPL Test display: DP-Gram, DPOAE level, noise level, test progress Result display: Overall Pass/Clear Response or Refer/No Clear Response, DP-Gram with DPOAE and noise level. with warranty SUB-TOTAL: Project Name: For CLLMMH Use. Place of Delivery: Cong. Lamberto L. Macias Memorial Hospital - Siaton TOTAL ABC 700,000.00 Created by Michael E Fonollera Date Created 24/10/2024 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. PROVINCE OF NEGROS ORIENTAL
|
|||
NAICS | ||||
CPVS |
Transmission, cam- and crank- shafts
Earthmoving and excavating machinery, and associated parts
Iron, lead, zinc, tin and copper
Probes
Hotel, restaurant and retail trade services
Batteries
Medical equipments
Medical equipments, pharmaceuticals and personal care products
Mains
Engineering, auxiliary, average, loss, actuarial and salvage insurance services
Speakers
Cable
PH meters
Lead
Meters
Labels
Gloves
Clocks
Cable, wire and related products
Work gloves
Seats, chairs and related products, and associated parts
Keys
Adapters
Display cases
Cable TV
Construction work for dams, canals, irrigation channels and aqueducts
Modems
Dates
Tools, locks, keys, hinges, fasteners, chain and springs
|
|||
UNSPSC |
Filters
pH meters
Q Meters
Docking stations
Display cases
Clocks
Labels
Storage
Statistics
Modems
General goods storage
Hotels
Trade agreements
Connectors
Machine made parts
Equipment cases
Interfaces
Hotel rooms
Printer, scanner and multifunctional equipment maintenance
Clinical laboratory and toxicology testing systems, components, and supplies
Clinical laboratory and toxicology testing systems, components, and supplies
|
|||
Regions | ||||
Sectors |
Environment and Pollution-Recycling
Automobiles and Auto Parts
Non-Renewable Energy
Solar Photovoltaic PV Energy
Postal and Courier Services
Roads and Highways-Bridge
Water and Sanitation
Law and Legal
Transportation
Printing and Publishing
Railways-Rail-Railroad
Defence and Security
Electricity
Construction
Agriculture-Food and Beverages
Energy-Power and Electrical
Sports and Leisure
Computer Hardwares and Consumables
Marine
|
|||
URL | ||||
Share |
Title |
---|
1 unit NBS HEARING MACHINE for CLLMMH-Siaton (N-1929-2024) PROVINCE OF NEGROS ORIENTAL |
Country |
Language |
English |
Organization |
Published Date |
25.10.2024 |
Deadline Date |
30.10.2024 |
Overview |
1 unit NBS HEARING MACHINE for CLLMMH-Siaton (N-1929-2024) Request for Quotation (RFQ) Reference Number 11399518 Procuring Entity PROVINCE OF NEGROS ORIENTAL Title 1 unit NBS HEARING MACHINE for CLLMMH-Siaton (N-1929-2024) Area of Delivery Negros Oriental Printable Version Solicitation Number: N-1929-2024 Trade Agreement: Implementing Rules and Regulations Procurement Mode: Negotiated Procurement - Small Value Procurement (Sec. 53.9) Classification: Goods Category: Hospital / Medical Equipment Approved Budget for the Contract: PHP 700,000.00 Delivery Period: 0 Day/s Client Agency: Contact Person: Michael E Fonollera Member, BAC Secretariat Ground Floor, Convention Hotel, Capitol Area, Dumaguete City Negros Oriental Philippines 6200 63-035-2263804 63-035-2251111 bac.secretariat.neg.or@gmail.com Status Active Associated Components Order Bid Supplements 0 Document Request List 0 Date Published 25/10/2024 Last Updated / Time 25/10/2024 12:00 AM Closing Date / Time 30/10/2024 1:00 AM Description 1 NBS HEARING MACHINE 1 UNIT 700,000.00 DEVICE MADSEN Alpha OAE+ is type 1077 from Natus Medical Denmark ApS. Dimensions Approx. 200 x 73 x 34 mm (7.9 x 2.9 x 1.3 inches) Weight Approx. 240 g (8.5 oz) excluding battery 280 g (9.9 oz) including battery Display Type: Color, TFT, touchscreen with adjustable LED backlight DIMENSIONS: 89.4MM (3.5 INCHES) Resolution: 240x320 pixels Keypad Resistive touchscreen (can be used with gloves) Sound Built-in speaker for key click and Pass/Clear Response and Refer/ No clear Response sounds Language settings Up to 7 user selectable languages available in selected language package Memory Patient memory capacity: Max. 250 patients Test memory capacity: Max. 500 test Battery Battery type: Rechargeable Li-ion 3.7 V/1800 mAh (6.7 Wh), fully charged DOCKING STATION PC interface Interface type: USB 2.0, Full-speed USB Power: Uses<100mA of current from the USB interface Printer/modem interface Interface type: RS232 Connector type: 6-pol Mini Din DC power input Input voltage: 5 V DC ±5% Max. power consumption when AccuScreen is docked: 5 VA(5V,1.0A) Max.power consumption when AccuScreen is not docked:0.25VA(5V,50mA) Power adapter Input voltage/range: 100-240 V AC, 50-60 Hz Output voltage: 5.0 V DC Output current: Minimum 1.0 A Mains plug types: US,UK,Europe and Australia Connectors OAE probe connector: 14 pin ODU Medisnap - For OAE+ Probe. Real time clock Integrated real time clock for time-stamping of measurements. The clock is automatically synchronized with PC clock when docked Accuracy: Max. deviation 12 minutes/year Backup: Min. 7 days, when battery is removed from unit Data interfaces PC: IR data transmission to docking station - USB interface from docking station to PC Label printer: IR data transmission to docking station - RS232 interface from docking station to label printer Modem: IR data transmission to docking station - RS232 interface from docking station to modem Transport and storage environment Temperature range: -20 - +60°C (-4 - 140°F) Humidity range: 10 - 90 % rel., non-condensing Air pressure:500 hPa to 1040 hP Operating environment Mode of operation: Continuous Temperature range: 10 - 40°C (50 - 104°F) Humidity range: 30 - 90 % rel., non-condensing Air pressure: 500 hPa* to 1060 hPa *At locations where the normal air pressure is below 800 hPa (at altitudes of more than 2000 meters), it is recommended to recalibrate the OAE probes and ABR ear coupler cable (if used) Warm-up time: < 20 seconds. Note: Warm-up time should be extended if MADSEN AccuScreen has been stored in a cold environment Measurement Techniques TEOAE Evaluation method: Noise-weighted averaging, counting of significant signal peaks Stimulus: Non-linear click sequence Stimulus level: 75 dB(A) ± 5 dB in 2 cc coupler, self-calibration depending on ear canal volume Click rate: 65-80 clicks per second (randomized) Input filter: 1 to 4 kHz Test display: Averaged waveform, no. of TEOAE peaks, probe fit assistant, noise level, anti- f act level,stability level and test progeress Result display: Averaged waveform, no. of TEOAE peaks and overall Pass/Clear Response or Refer/No Clear Response.On Refer/No Clear Response also probe fit assist-ant noise level' artifact level and stability level. DPOAE Evaluation method: Noise-weighted phase statistics Stimulus: Primary tone pair, F2/F1 = 1.24 Available test frequencies: F2 = 1, 1.5, 2, 3, 3.5, 4, 5 and 6 kHz Default test frequencies: F2 = 2, 3, 4 and 5 kHz (Pass/Clear Response at 3 out of 4) Available test levels: L1/L2 = 60/50 dB SPL and L1/L2 = 65/55 dB SPL Default test level: L1/L2 = 60/50 dB SPL Test display: DP-Gram, DPOAE level, noise level, test progress Result display: Overall Pass/Clear Response or Refer/No Clear Response, DP-Gram with DPOAE and noise level. with warranty SUB-TOTAL: Project Name: For CLLMMH Use. Place of Delivery: Cong. Lamberto L. Macias Memorial Hospital - Siaton TOTAL ABC 700,000.00 Created by Michael E Fonollera Date Created 24/10/2024 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. PROVINCE OF NEGROS ORIENTAL |
NAICS |
Power Instruments and Related Products Manufacturing for Measuring Regulation Copper Machinery Regulation Medical Environment Electroplating Agencies Copper Medical |
CPVS |
Transmission, cam- and crank- shafts Earthmoving and excavating machinery, and associated parts Iron, lead, zinc, tin and copper Probes Hotel, restaurant and retail trade services Batteries Medical equipments Medical equipments, pharmaceuticals and personal care products Mains Engineering, auxiliary, average, loss, actuarial and salvage insurance services Speakers Cable PH meters Lead Meters Labels Gloves Clocks Cable, wire and related products Work gloves Seats, chairs and related products, and associated parts Keys Adapters Display cases Cable TV Construction work for dams, canals, irrigation channels and aqueducts Modems Dates Tools, locks, keys, hinges, fasteners, chain and springs |
UNSPSC |
Filters pH meters Q Meters Docking stations Display cases Clocks Labels Storage Statistics Modems General goods storage Hotels Trade agreements Connectors Machine made parts Equipment cases Interfaces Hotel rooms Printer, scanner and multifunctional equipment maintenance Clinical laboratory and toxicology testing systems, components, and supplies Clinical laboratory and toxicology testing systems, components, and supplies |
Regions |
APEC Countries Asia |
Sectors |
Environment and Pollution-Recycling Automobiles and Auto Parts Non-Renewable Energy Solar Photovoltaic PV Energy Postal and Courier Services Roads and Highways-Bridge Water and Sanitation Law and Legal Transportation Printing and Publishing Railways-Rail-Railroad Defence and Security Electricity Construction Agriculture-Food and Beverages Energy-Power and Electrical Sports and Leisure Computer Hardwares and Consumables Marine |
URL |
Share |
To be notified
when a tender matching your filter is
published
To Follow
Tenders
Add New Tender Alert
To Follow
Contracts
Add New Contract Alert
To Follow
Fairs
Add New Fair Alert
Similar Tenders