Sign up now to have the right to view
10 tenders for free.
Title |
20-Ton Industrial Water Chiller Solicitation DEPT OF DEFENSE
|
---|---|
Country | |
Language | English |
Organization | |
Published Date | 06.06.2024 |
Deadline Date | 17.06.2024 |
Overview | 20-Ton Industrial Water Chiller Solicitation Technical Specifications 20 Ton Industrial Water Chiller 1. General Operational Data/Specifications a. Must be rated for continuous usage b.&n FA910124IndustrialWaterChiller America/Chicago DEPT OF DEFENSE 20-Ton Industrial Water Chiller America/Chicago eMail : brogan.fullmer@us.af.mil Brogan Fullmer Tennessee USA UNITED STATES FA910124IndustrialWaterChiller Technical Specifications 20 Ton Industrial Water Chiller 1. General & Operational Data/Specifications a. Must be rated for continuous usage b. Ambient working limits: Minimum requirements are +14 Fahrenheit (ᴼF) or -10 Celsius (°C) through +113 ᴼF or 45 °C c. Cooling capacity (Capacity based on 45 ᴼF or 7.22 °C water outlet temperature): 10 ᴼF or -12.22 °C delta at 95 ᴼF or 35 °C ambient temperature i. Twenty (20) tons, minimum capacity ii. 239,756 British thermal units (BTUs) per hour (BTUs/hr.), minimum capacity d. Must be designed to use water as a medium e. Cooling Water flow rate: 50 gallons per minute (GPM) or 189.27 liters (L), minimum flow rate f. Head Pressure: Fifty (50) pounds per square inch (PSI) at a flow rate of 46 gallons or 174.12L per minute (GPM) g. Refrigerant Type: R-410A h. Noise rating: Not-to-exceed 69 decibels (dBs) at thirty-two feet (32’) or 10 meters (m) 2. Reservoir/Self-Contained Water Tank: a. Fifty-five (55) gallon or 208.19L minimum capacity b. Chiller is to only operate using water contained in a reservoir/self-contained tank; an external water supply IS NOT required, except to fill the reservoir/self-contained tank. c. Tank is to be stainless steel. 3. Interfaces: a. Power Supply: i. Volts (V): 460V ii. Phase: Three (3) phase alternating current (AC) iii. Hertz (Hz): 60Hz iv. Full Load Amps (FLA): Maximum of 60 FLA b. Fluid Connections i. System water supply: male pipe thread (MPT) two inches (2”) or 5.08 centimeters (cm) ii. System water return: male pipe thread (MPT) two inches (2”) 5.08cm c. Filling reservoir/self-contained tank with drain 4. Weight & Dimensions: System must fit within below dimensions (Note, Reservoir/Self-Contained water tank is included in these measurements a. Dry Weight in pounds (lbs): Not-to-exceed two-thousand six-hundred sixty pounds (2,660 lbs) or 1206.55 kilograms (kg) b. Width: Not-to-exceed forty-five inches (45”) or 114.3cm c. Length/Depth: Not-to-exceed one-hundred inches (100”) 254cm d. Height: Not-to-exceed ninety inches (90”) 228.6cm 5. Portability a. Portability must be maintained while meeting all requirements in these specifications b. System must be self-contained on a movable skid/frame c. Skid/frame is to have lifting hole to allow forklift to move system d. Only permitted items to be disconnected for portability are: i. Power Source identified in 3.a.iv ii. Fluid connections identified in 3.b.i and 3.b.ii e. Drain reservoir/self-contained tank of water 6. Clearance Spacing. The following states minimum space must be provided between the system and an obstacle-- a. Side Clearances: Required clearance for any side of unit is not-to-exceed six and one-half feet (6.5’) or 1.98m b. Top Clearance: Required clearance for top of unit is not-to-exceed ten feet (10’) or 3.04m See attached vendor questions and answers (Q&A) from the technical evaluator. NAICS Code : 333415 PSC Code : 4120 Phone : |
NAICS | |
CPVS |
Dried, salted, smoked or seasoned meat
Tanks
Tanks, reservoirs, containers and pressure vessels
System, storage and content management software package
Pipes
PH meters
Tanks, reservoirs and containers; central-heating radiators and boilers
Meters
Squares
Permits
Machinery for cleaning, filling, packing or wrapping bottles or other containers
Water tanks
Dry goods
System, storage and content management software development services
Lifting, handling, loading or unloading machinery
Parts of dishwashing machines and of machines for cleaning, filling, packing or wrapping
Drain
Steel
Pipeline, piping, pipes, casing, tubing and related items
Designs
|
UNSPSC | |
Regions | |
Sectors |
Environment and Pollution-Recycling
Automobiles and Auto Parts
Non-Renewable Energy
Supply
Solar Photovoltaic PV Energy
Stainless Steel and Galvanized
Bridges and Tunnels
Roads and Highways-Bridge
Infrastructure
Water and Sanitation
Printing and Publishing
Defence and Security
Electricity
Construction
Energy-Power and Electrical
Computer Hardwares and Consumables
Steel
Industry
Aviation
Construction Materials
Marine
|
URL |
Share |
Title |
---|
20-Ton Industrial Water Chiller Solicitation DEPT OF DEFENSE
|
Country |
Language |
English |
Organization |
Published Date |
06.06.2024 |
Deadline Date |
17.06.2024 |
Overview |
20-Ton Industrial Water Chiller Solicitation Technical Specifications 20 Ton Industrial Water Chiller 1. General Operational Data/Specifications a. Must be rated for continuous usage b.&n FA910124IndustrialWaterChiller America/Chicago DEPT OF DEFENSE 20-Ton Industrial Water Chiller America/Chicago eMail : brogan.fullmer@us.af.mil Brogan Fullmer Tennessee USA UNITED STATES FA910124IndustrialWaterChiller Technical Specifications 20 Ton Industrial Water Chiller 1. General & Operational Data/Specifications a. Must be rated for continuous usage b. Ambient working limits: Minimum requirements are +14 Fahrenheit (ᴼF) or -10 Celsius (°C) through +113 ᴼF or 45 °C c. Cooling capacity (Capacity based on 45 ᴼF or 7.22 °C water outlet temperature): 10 ᴼF or -12.22 °C delta at 95 ᴼF or 35 °C ambient temperature i. Twenty (20) tons, minimum capacity ii. 239,756 British thermal units (BTUs) per hour (BTUs/hr.), minimum capacity d. Must be designed to use water as a medium e. Cooling Water flow rate: 50 gallons per minute (GPM) or 189.27 liters (L), minimum flow rate f. Head Pressure: Fifty (50) pounds per square inch (PSI) at a flow rate of 46 gallons or 174.12L per minute (GPM) g. Refrigerant Type: R-410A h. Noise rating: Not-to-exceed 69 decibels (dBs) at thirty-two feet (32’) or 10 meters (m) 2. Reservoir/Self-Contained Water Tank: a. Fifty-five (55) gallon or 208.19L minimum capacity b. Chiller is to only operate using water contained in a reservoir/self-contained tank; an external water supply IS NOT required, except to fill the reservoir/self-contained tank. c. Tank is to be stainless steel. 3. Interfaces: a. Power Supply: i. Volts (V): 460V ii. Phase: Three (3) phase alternating current (AC) iii. Hertz (Hz): 60Hz iv. Full Load Amps (FLA): Maximum of 60 FLA b. Fluid Connections i. System water supply: male pipe thread (MPT) two inches (2”) or 5.08 centimeters (cm) ii. System water return: male pipe thread (MPT) two inches (2”) 5.08cm c. Filling reservoir/self-contained tank with drain 4. Weight & Dimensions: System must fit within below dimensions (Note, Reservoir/Self-Contained water tank is included in these measurements a. Dry Weight in pounds (lbs): Not-to-exceed two-thousand six-hundred sixty pounds (2,660 lbs) or 1206.55 kilograms (kg) b. Width: Not-to-exceed forty-five inches (45”) or 114.3cm c. Length/Depth: Not-to-exceed one-hundred inches (100”) 254cm d. Height: Not-to-exceed ninety inches (90”) 228.6cm 5. Portability a. Portability must be maintained while meeting all requirements in these specifications b. System must be self-contained on a movable skid/frame c. Skid/frame is to have lifting hole to allow forklift to move system d. Only permitted items to be disconnected for portability are: i. Power Source identified in 3.a.iv ii. Fluid connections identified in 3.b.i and 3.b.ii e. Drain reservoir/self-contained tank of water 6. Clearance Spacing. The following states minimum space must be provided between the system and an obstacle-- a. Side Clearances: Required clearance for any side of unit is not-to-exceed six and one-half feet (6.5’) or 1.98m b. Top Clearance: Required clearance for top of unit is not-to-exceed ten feet (10’) or 3.04m See attached vendor questions and answers (Q&A) from the technical evaluator. NAICS Code : 333415 PSC Code : 4120 Phone : |
NAICS |
Power Scenic and Sightseeing Transportation Commercial Military Armored Vehicle Dry Water Boiler |
CPVS |
Dried, salted, smoked or seasoned meat Tanks Tanks, reservoirs, containers and pressure vessels System, storage and content management software package Pipes PH meters Tanks, reservoirs and containers; central-heating radiators and boilers Meters Squares Permits Machinery for cleaning, filling, packing or wrapping bottles or other containers Water tanks Dry goods System, storage and content management software development services Lifting, handling, loading or unloading machinery Parts of dishwashing machines and of machines for cleaning, filling, packing or wrapping Drain Steel Pipeline, piping, pipes, casing, tubing and related items Designs |
UNSPSC |
Threads Forklifts Tanks Power sources Drain pH meters Q Meters T squares Water Interfaces IP phones Refrigerant Power Supply, Computer Water, sanitation and hygiene kits Power supply Water, sanitation and hygiene kit Water, sanitation and hygiene kits |
Regions |
APEC Countries North America Northern America |
Sectors |
Environment and Pollution-Recycling Automobiles and Auto Parts Non-Renewable Energy Supply Solar Photovoltaic PV Energy Stainless Steel and Galvanized Bridges and Tunnels Roads and Highways-Bridge Infrastructure Water and Sanitation Printing and Publishing Defence and Security Electricity Construction Energy-Power and Electrical Computer Hardwares and Consumables Steel Industry Aviation Construction Materials Marine |
URL |
Share |
To be notified
when a tender matching your filter is
published
To Follow
Tenders
Add New Tender Alert
To Follow
Contracts
Add New Contract Alert
To Follow
Fairs
Add New Fair Alert
Similar Tenders